Schema Changes:
Attributes (generally size and dimensions) added to REGULATORS, BASES and HOUSINGS. Changed primary keys on CONNECTION_ORIENTATIONS, FILTERS, REGULATORS to be 'code' rather than 'id'-based. Altered ENQUIRIES to make contact names, addresses and contact mechanisms explicit within the enquiry rather than using the general contact mechanism. Seed Data: Changed 'code' values for HOUSING_TYPES, METER_TYPES, REGULATOR_TYPES and SERVICE_PRESSURES to match their descriptions. Documentation: Updated Documentation/Design/DatabaseItemToFunctionalSpecificationReference.xls in line with schema changes. Demo Data: Includes modules and related data from the MIP140306 Access database. git-svn-id: http://locode01.ad.dom/svn/WEBMIP/trunk@2857 248e525c-4dfb-0310-94bc-949c084e9493
This commit is contained in:
@@ -1,14 +1,16 @@
|
||||
-- C:\Andy\svn\WEBMIP\Schema\mip.tab
|
||||
--
|
||||
-- Generated for Oracle 10g on Wed Nov 14 10:03:44 2007 by Server Generator 10.1.2.6.18
|
||||
-- Generated for Oracle 10g on Thu Nov 15 10:19:01 2007 by Server Generator 10.1.2.6.18
|
||||
|
||||
|
||||
|
||||
PROMPT Creating Table 'REGULATORS'
|
||||
CREATE TABLE REGULATORS
|
||||
(RETY_CODE VARCHAR2(80) NOT NULL
|
||||
(CODE VARCHAR2(80) NOT NULL
|
||||
,RETY_CODE VARCHAR2(80) NOT NULL
|
||||
,DESCRIPTION VARCHAR2(80)
|
||||
,REGULATOR_SIZE NUMBER NOT NULL
|
||||
,LOCK_UP NUMBER NOT NULL
|
||||
,ID NUMBER(*,0) NOT NULL
|
||||
)
|
||||
/
|
||||
|
||||
@@ -103,8 +105,8 @@ CREATE TABLE COSTS
|
||||
|
||||
PROMPT Creating Table 'CONNECTION_ORIENTATIONS'
|
||||
CREATE TABLE CONNECTION_ORIENTATIONS
|
||||
(DESCRIPTION VARCHAR2(80)
|
||||
,ID NUMBER(*,0) NOT NULL
|
||||
(CODE VARCHAR2(80) NOT NULL
|
||||
,DESCRIPTION VARCHAR2(80)
|
||||
)
|
||||
/
|
||||
|
||||
@@ -135,9 +137,9 @@ CREATE TABLE PARTY_CONTACT_MECHANISM_ROLES
|
||||
|
||||
PROMPT Creating Table 'FILTERS'
|
||||
CREATE TABLE FILTERS
|
||||
(FITY_CODE VARCHAR2(80) NOT NULL
|
||||
(CODE VARCHAR2(80) NOT NULL
|
||||
,FITY_CODE VARCHAR2(80) NOT NULL
|
||||
,FILTER_SIZE NUMBER NOT NULL
|
||||
,ID NUMBER(*,0) NOT NULL
|
||||
)
|
||||
/
|
||||
|
||||
@@ -287,7 +289,7 @@ CREATE TABLE ASSET_LOCATION_TYPES
|
||||
PROMPT Creating Table 'METERS'
|
||||
CREATE TABLE METERS
|
||||
(CODE VARCHAR2(80) NOT NULL
|
||||
,DRWG_CODE VARCHAR2(80) NOT NULL
|
||||
,DRWG_CODE VARCHAR2(80)
|
||||
,METY_CODE VARCHAR2(80) NOT NULL
|
||||
,PRTY_ID NUMBER(*,0) NOT NULL
|
||||
,DIM_A NUMBER NOT NULL
|
||||
@@ -358,14 +360,21 @@ CREATE TABLE ACCESS_CONTROLS
|
||||
PROMPT Creating Table 'ENQUIRIES'
|
||||
CREATE TABLE ENQUIRIES
|
||||
(CODE VARCHAR2(80) NOT NULL
|
||||
,CONSUMER_COMT_CODE VARCHAR2(80)
|
||||
,CONSUMER_CONTACT_VALUE VARCHAR2(240)
|
||||
,REQUIRED_MESC_CODE VARCHAR2(80)
|
||||
,FIRST_CONTACT_FAX VARCHAR2(15)
|
||||
,FIRST_CONTACT_EMAIL VARCHAR2(240)
|
||||
,SECOND_CONTACT_TELEPHONE_1 VARCHAR2(15)
|
||||
,SECOND_CONTACT_FAX VARCHAR2(15)
|
||||
,INSTALL_BUILDING VARCHAR2(40)
|
||||
,INSTALL_CITY VARCHAR2(40)
|
||||
,INSTALL_POSTCODE VARCHAR2(7)
|
||||
,ALT_BUILDING VARCHAR2(40)
|
||||
,SECOND_ALT_SUB_BUILDING VARCHAR2(40)
|
||||
,FIRST_ALT_BUILDING VARCHAR2(40)
|
||||
,SECOND_ALT_STREET VARCHAR2(60)
|
||||
,SECOND_ALT_CITY VARCHAR2(40)
|
||||
,SECOND_ALT_POSTCODE VARCHAR2(7)
|
||||
,ASSET_LOCATION_NOTES VARCHAR2(100)
|
||||
,MPRN INTEGER
|
||||
,MPRN NUMBER(30,0)
|
||||
,REQUIRED_METERING_PRESSURE NUMBER
|
||||
,REQUIRED_IP_DETAILS VARCHAR2(250)
|
||||
,REQUIRED_IP_MBAR NUMBER
|
||||
@@ -382,17 +391,19 @@ CREATE TABLE ENQUIRIES
|
||||
,EXISTING_MESC_CODE VARCHAR2(80)
|
||||
,EXISTING_SVCP_CODE VARCHAR2(80)
|
||||
,METY_CODE VARCHAR2(80)
|
||||
,REQUIRED_MESC_CODE VARCHAR2(80)
|
||||
,REQUIRED_SVCP_CODE VARCHAR2(80)
|
||||
,AGENT_CONTACT_VALUE VARCHAR2(240)
|
||||
,TRANSACTION_REFERENCE VARCHAR2(80)
|
||||
,CONSUMER_NAME VARCHAR2(80)
|
||||
,SECOND_CONTACT_TELEPHONE_2 VARCHAR2(15)
|
||||
,SECOND_CONTACT_EMAIL VARCHAR2(240)
|
||||
,INSTALL_SUB_BUILDING VARCHAR2(40)
|
||||
,INSTALL_STREET VARCHAR2(60)
|
||||
,ALT_CONSUMER_NAME VARCHAR2(80)
|
||||
,ALT_STREET VARCHAR2(60)
|
||||
,ALT_CITY VARCHAR2(40)
|
||||
,ALT_POSTCODE VARCHAR2(7)
|
||||
,SECOND_CONTACT_NAME VARCHAR2(80)
|
||||
,FIRST_ALT_STREET VARCHAR2(60)
|
||||
,FIRST_ALT_CITY VARCHAR2(40)
|
||||
,FIRST_ALT_POSTCODE VARCHAR2(7)
|
||||
,SECOND_ALT_BUILDING VARCHAR2(40)
|
||||
,ACCESS_PASSWORD VARCHAR2(30)
|
||||
,ACCESS_ADDITIONAL VARCHAR2(210)
|
||||
,INDICATIVE_DATE DATE
|
||||
@@ -409,9 +420,9 @@ CREATE TABLE ENQUIRIES
|
||||
,JOB_DESCRIPTION VARCHAR2(500)
|
||||
,CREATED_BY NUMBER NOT NULL
|
||||
,AGENT_COMT_CODE VARCHAR2(80)
|
||||
,ALT_CONSUMER_COMT_CODE VARCHAR2(80)
|
||||
,ALT_CONSUMER_CONTACT_VALUE VARCHAR2(240)
|
||||
,ALT_SUB_BUILDING VARCHAR2(40)
|
||||
,FIRST_CONTACT_TELEPHONE_1 VARCHAR2(15)
|
||||
,FIRST_CONTACT_TELEPHONE_2 VARCHAR2(15)
|
||||
,FIRST_ALT_SUB_BUILDING VARCHAR2(40)
|
||||
,MPRN_ALT VARCHAR2(250)
|
||||
,ANNUAL_QUANTITY NUMBER
|
||||
,DOWNSTREAM_BOOSTER_OR_COMPRESS VARCHAR2(3)
|
||||
@@ -426,8 +437,17 @@ CREATE TABLE ENQUIRIES
|
||||
PROMPT Creating Table 'BASES'
|
||||
CREATE TABLE BASES
|
||||
(CODE VARCHAR2(80) NOT NULL
|
||||
,DRWG_CODE VARCHAR2(80) NOT NULL
|
||||
,DRWG_CODE VARCHAR2(80)
|
||||
,DESCRIPTION VARCHAR2(80)
|
||||
,DIM_A NUMBER
|
||||
,DIM_B NUMBER
|
||||
,DIM_C NUMBER
|
||||
,DIM_D NUMBER
|
||||
,DIM_E NUMBER
|
||||
,DIM_F NUMBER
|
||||
,DIM_G NUMBER
|
||||
,DIM_H NUMBER
|
||||
,DIM_I NUMBER
|
||||
)
|
||||
/
|
||||
|
||||
@@ -463,14 +483,15 @@ CREATE TABLE METER_TYPES
|
||||
PROMPT Creating Table 'MODULES'
|
||||
CREATE TABLE MODULES
|
||||
(CODE VARCHAR2(80) NOT NULL
|
||||
,INLET_CNOR_ID NUMBER(*,0) NOT NULL
|
||||
,OUTLET_CNOR_ID NUMBER(*,0) NOT NULL
|
||||
,OUTLET_CNTY_CODE VARCHAR2(80) NOT NULL
|
||||
,INLET_CNTY_CODE VARCHAR2(80) NOT NULL
|
||||
,DRWG_CODE VARCHAR2(80) NOT NULL
|
||||
,FLTR_ID NUMBER(*,0) NOT NULL
|
||||
,FLTR_CODE VARCHAR2(80) NOT NULL
|
||||
,INLET_CNOR_CODE VARCHAR2(80) NOT NULL
|
||||
,INLET_CNTY_CODE VARCHAR2(80) NOT NULL
|
||||
,METR_CODE VARCHAR2(80) NOT NULL
|
||||
,REGU_ID NUMBER(*,0) NOT NULL
|
||||
,OUTLET_CNOR_CODE VARCHAR2(80) NOT NULL
|
||||
,OUTLET_CNTY_CODE VARCHAR2(80) NOT NULL
|
||||
,PRTY_ID NUMBER(*,0) NOT NULL
|
||||
,REGU_CODE VARCHAR2(80) NOT NULL
|
||||
,REVA_CODE VARCHAR2(80) NOT NULL
|
||||
,SLVA_CODE VARCHAR2(80) NOT NULL
|
||||
,SVCP_CODE VARCHAR2(80) NOT NULL
|
||||
@@ -494,6 +515,9 @@ CREATE TABLE MODULES
|
||||
)
|
||||
/
|
||||
|
||||
COMMENT ON COLUMN MODULES.PRTY_ID IS 'Manufacturer of the module'
|
||||
/
|
||||
|
||||
PROMPT Creating Table 'HOUSINGS'
|
||||
CREATE TABLE HOUSINGS
|
||||
(CODE VARCHAR2(80) NOT NULL
|
||||
@@ -501,6 +525,10 @@ CREATE TABLE HOUSINGS
|
||||
,HOTY_CODE VARCHAR2(80) NOT NULL
|
||||
,PRTY_ID NUMBER(*,0) NOT NULL
|
||||
,DESCRIPTION VARCHAR2(80)
|
||||
,DIM_L VARCHAR2(240) NOT NULL
|
||||
,DIM_W NUMBER NOT NULL
|
||||
,DIM_H NUMBER NOT NULL
|
||||
,WEIGHT NUMBER NOT NULL
|
||||
)
|
||||
/
|
||||
|
||||
@@ -528,6 +556,7 @@ CREATE TABLE FILTER_TYPES
|
||||
PROMPT Creating Table 'DRAWINGS'
|
||||
CREATE TABLE DRAWINGS
|
||||
(CODE VARCHAR2(80) NOT NULL
|
||||
,DESCRIPTION VARCHAR2(80)
|
||||
)
|
||||
/
|
||||
|
||||
|
||||
Reference in New Issue
Block a user