COLUMN_NAME ,Appendix Reference,INSTALL,STD INSTALL,OFMAT,EXCHANGE,STD EXCHANGE,REMOVE,STD REMOVE,ADVERSARIAL,ALTERATION,CHANGE CAPACITY,"ADDONS(EMS,AMR)",OTHER,Notes,DisplaySequence AGENT_COMT_CODE,Supplier Agent.Telephone1/Telephone2/Fax/Email,M,M,M,M,M,M,M,M,M,M,M,M,,4 AGENT_CONTACT_VALUE,Supplier Agent.Telephone1/Telephone2/Fax/Email,M,M,M,M,M,M,M,M,M,M,M,M,,5 ACCESS_ADDITIONAL,Site Detail.Access Instructions,O,O,O,O,O,O,O,O,O,O,O,O,,6 ACCESS_PASSWORD,Site Detail.Access Password,O,O,O,O,O,O,O,O,O,O,O,O,,7 MPRN_ALT,Site Detail.Additional Information,O-M4,O-M4,O,O,O,O,O,O,O,O,O,O,,8 ALTY_CODE,Site Detail.Asset Location Code,M,M,M,M,M,M,M,M,M,M,M,M,,9 ASSET_LOCATION_NOTES,Site Detail.Asset Location Notes,O,O,O,O,O,O,O,O,O,O,O,O,,10 CACA_CODE,Site Detail.Care Category,O,O,O,O,O,O,O,O,O,O,O,O,,11 MPRN,Site Detail.MPRN,O-M4,O-M4,M,M,M,M,M,M,M,M,M,O,,12 TRANSACTION_REFERENCE,Job Site Details.Transaction Reference,O,O,O,O,O,O,O,O,O,O,O,O,,13 INSTALL_SUB_BUILDING,Address.Sub Building,O-M1,O-M1,O-M1,O-M1,O-M1,O-M1,O-M1,O-M1,O-M1,O-M1,O-M1,O-M1,,14 INSTALL_BUILDING,Address.Building,O-M1,O-M1,O-M1,O-M1,O-M1,O-M1,O-M1,O-M1,O-M1,O-M1,O-M1,O-M1,,15 INSTALL_STREET,Address.Street,M,M,M,M,M,M,M,M,M,M,M,M,,16 INSTALL_CITY,Address.City,M,M,M,M,M,M,M,M,M,M,M,M,,17 INSTALL_POSTCODE,Address.Post Code,M,M,M,M,M,M,M,M,M,M,M,M,,18 FIRST_CONTACT_TITLE,Contact Address.Contact Title,O,O,O,O,O,O,O,O,O,O,O,O,,19 FIRST_CONTACT_INITIALS,Contact Address.Contact Initials,O,O,O,O,O,O,O,O,O,O,O,O,,20 FIRST_CONTACT_NAME,Address.Contact Name,M,M,M,M,M,M,M,M,M,M,M,M,,21 FIRST_CONTACT_TELEPHONE_1,Contact Address.Telephone1,M,M,M,M,M,M,M,M,M,M,M,M,,22 BASE_REQUIRED,Job Information.Additional Services.Base,M,M,H,M,M,H,H,H,M,M,H,M,,23 BYPASS_REQUIRED,Job Information.Additional Services.By-pass,O,O,H,O,O,H,H,H,O,O,O,O,"If yes, warn user if twin stream is no",24 CONVERTOR_REQUIRED,Job Information.Additional Services.Convertor,M,M,H,M,M,H,H,H,M,M,M,M,this can be an add-on for removals,25 EMS_REQUIRED,Job Information.Additional Services.EMS,M,M,H,M,M,H,H,H,M,M,M,M,,26 HOUSING_REQUIRED,Job Information.Additional Services.Housing,M,M,H,M,M,H,H,H,M,M,H,M,,27 PURGING_REQUIRED,Job Information.Additional Services.Purging,H,H,H,H,H,M,M,H,O,H,H,O,,28 TWIN_STREAM_REQUIRED,Job Information.Additional Services.Twin Stream,M,M,H,M,M,H,H,H,M,M,H,M,,29 EXISTING_LOGGER,Job Information.Logger,H,H,H,O,O,O,O,O,O,O,O,O,,30 EXISTING_CONVERTOR,Job Information.Existing Convertor,H,H,O,M,M,M,M,M,O,O,O,O,,31 ANNUAL_QUANTITY,Job Information.Annual Quantity,O,O,O,O,O,H,H,H,O,O,O,O,if > 732 mwh go bespoke,32 INDICATIVE_TIME,Job Information.Appointment Preference,O,O,O,O,O,O,O,O,O,O,O,O,,33 DOWNSTREAM_BOOSTER_OR_COMPRESS,Job Information.Booster/Compressor,M,M,M,M,M,H,H,H,M,M,M,M,,34 EXISTING_METER_SERIAL_NO,Job Information.Existing Asset Serial Number,H,H,M,M,M,M,M,M,M,M,M,O,,35 EXISTING_MESC_CODE,Job Information.Existing Meter Size,H,H,O-M6,O-M6,O-M6,O-M6,O-M6,O-M6,O-M6,O-M6,O,O,,36 EXISTING_METY_CODE,Job Information.Meter Type Existing ,H,H,O-M6,O-M6,O-M6,O-M6,O-M6,O-M6,O-M6,O-M6,O,O,,37 EXISTING_METER_OWNER,Job Information.Gas Act Owner,O,O,M,M,M,M,M,M,M,M,M,O,,38 INDICATIVE_DATE,Job Information.Indicative Substantial Completion Date,O,O,O,O,O,O,O,O,O,O,O,O,,39 REQUIRED_IP_MBAR,Job Information.IP Inlet pressure,O-M3,H,O-M3,O-M3,H,O-M3,H,O-M3,O-M3,O-M3,O-M3,O-M3,if service pressure is IP,40 JOB_DESCRIPTION,Job Information.Job Description,O,O,O,O,O,O,O,O,O,O,O,O,,41 ENTY_CODE,Job Information.Job Type,M,M,M,M,M,M,M,M,M,M,M,M,,42 LOAD_CONTROL_TYPE,Job Information.Load Control Type,M,M,H,M,M,H,H,H,O,M,O,O,,43 MARKET_SECTOR_CODE,Job Information.Market Sector Code,O,O,O,O,O,O,O,O,O,O,O,O,,44 QMAX,Job Information.Measuring Capacity Qmax,M,O-M2,O,M,O-M2,O,O,O,O,O-M2,O,O,,45 QMIN,Job Information.Measuring Capacity Qmin,O,O,O,O,O,O,O,O,O,O,O,O,,46 REQUIRED_MESC_CODE,Job Information.Meter Size,H,O-M2,H,H,O-M2,H,H,H,H,O-M2,H,O,,47 EXISTING_METR_CODE,Job Information.Existing Model Code,H,H,M,M,M,M,M,M,O,M,O,O,,48 OTHER_INFORMATION,Job Information.Other Information,O,O,O,O,O,O,O,O,O,O,O,O,,49 OTHER_PROJECT_REFERENCE,Job Information.Other Related Projects,O,O,O,O,O,O,O,O,O,O,O,O,,50 REQUIRED_METERING_PRESSURE,Job Information.Required Meter Pressure,M,M,M,M,M,M,M,M,M,M,O,O,,51 REQUIRED_SVCP_CODE,Job Information.Service Pressure,O-M3,M,O-M3,O-M3,M,O-M3,M,O-M3,O-M3,O-M3,O-M3,O-M3,,52 EXISTING_METER_ASSET_PROVIDER,Job Information.Supplier / Job Information.Consumer(Meter Asset Manager),O,O,O,O,O,O,O,O,O,O,O,O,,53 EXISTING_PRTY_ID,Job Information.Existing Manufacturer,H,H,M,M,M,M,M,M,O,O,O,O,,54 FIRST_ALT_BUILDING,Contact Address.Building,O,O,O,O,O,O,O,O,O,O,O,O,, FIRST_ALT_CITY,Contact Address.City,O,O,O,O,O,O,O,O,O,O,O,O,, FIRST_CONTACT_EMAIL,Contact Address.Email,O,O,O,O,O,O,O,O,O,O,O,O,, SECOND_CONTACT_EMAIL,Second Contact Address.Email,O,O,O,O,O,O,O,O,O,O,O,O,, FIRST_CONTACT_FAX,Contact Address.Fax,O,O,O,O,O,O,O,O,O,O,O,O,, SECOND_CONTACT_FAX,Contact Address.Fax,O,O,O,O,O,O,O,O,O,O,O,O,, FIRST_ALT_POSTCODE,Contact Address.Post Code,O,O,O,O,O,O,O,O,O,O,O,O,, SECOND_CONTACT_TITLE,Second Contact Address.Contact Title,O,O,O,O,O,O,O,O,O,O,O,O,, SECOND_CONTACT_INITIALS,Second Contact Address.Contact Initials,O,O,O,O,O,O,O,O,O,O,O,O,, SECOND_CONTACT_NAME,Second Contact Address.Second Contact Name,O,O,O,O,O,O,O,O,O,O,O,O,, FIRST_ALT_STREET,Contact Address.Street,O,O,O,O,O,O,O,O,O,O,O,O,, FIRST_ALT_SUB_BUILDING,Contact Address.Sub Building,O,O,O,O,O,O,O,O,O,O,O,O,, SECOND_CONTACT_TELEPHONE_1,Contact Address.Telephone1,O,O,O,O,O,O,O,O,O,O,O,O, AMR_REQUIRED,Job Information.Additional Services.AMR,O-M5,O-M5,H,O-M5,O-M5,H,H,H,O-M5,O-M5,O-M5,O-M5,"The AMR may only be available for the Tripartite suppliers or BG, GW to confirm!" BYPASS_OTHER,Job Information.Additional Services.By-pass Other,O-M7,O-M7,H,O-M7,O-M7,H,H,H,O-M7,O-M7,O-M7,O-M7, CREATED_ON,,,,,,,,,,,,,, FIRST_CONTACT_TELEPHONE_2,Contact Address.Telephone2,O,O,O,O,O,O,O,O,O,O,O,O, ID,Enquiry Reference (not in spec appendix),M,M,M,M,M,M,M,M,M,M,M,M, REQUIRED_IP_DETAILS,Job Information.IP Details,O-M3,H,O-M3,O-M3,H,O-M3,H,O-M3,O-M3,O-M3,O-M3,O-M3,if service pressure is IP SECOND_ALT_BUILDING,Second Contact Address.Building,O,O,O,O,O,O,O,O,O,O,O,O, SECOND_ALT_CITY,Second Contact Address.City,O,O,O,O,O,O,O,O,O,O,O,O, SECOND_ALT_POSTCODE,Second Contact Address.Post Code,O,O,O,O,O,O,O,O,O,O,O,O, SECOND_ALT_STREET,Second Contact Address.Street,O,O,O,O,O,O,O,O,O,O,O,O, SECOND_ALT_SUB_BUILDING,Second Contact Address.Sub Building,O,O,O,O,O,O,O,O,O,O,O,O, SECOND_CONTACT_TELEPHONE_2,Contact Address.Telephone2,O,O,O,O,O,O,O,O,O,O,O,O, UPDATED_BY,,,,,,,,,,,,,, UPDATED_ON,,,,,,,,,,,,,, ,Optional-Mandatory Special Cases ,O-M1: INSTALL_SUB_BUILDING AND/OR INSTALL.BUILDING MUST BE COMPLETED ,O-M2: IF REQUIRED_MESC_CODE IS NOT COMPLETED OR IS 'OTHER' THEN QMAX MUST BE COMPLETED ,O-M3: IF REQUIRED_SVCP_CODE = 'IP' THEN REQUIRED_IP_DETAILS MUST BE COMPLETED ,O-M4: IF MPRN IS NOT COMPLETED THEN MPRN_ALT MUST BE COMPLETED ,O-M5: AMR AVAILABILITY IS DETERMINED BY TRIPARTITE AGREEMENT ,O-M6: IF EXISTING_METR_CODE IS 'OTHER' THEN EXISTING_MESC_CODE AND EXISTING_METY_CODE MUST BE COMPLETED ,O-M7: IF BY_PASS IS 'OTHER' THEN BYPASS_OTHER MUST BE COMPLETED