Changes made to support Bulk Load.
git-svn-id: http://locode01.ad.dom/svn/WEBMIP/trunk@3255 248e525c-4dfb-0310-94bc-949c084e9493
This commit is contained in:
53
Data/BulkLoad/BASES.csv
Normal file
53
Data/BulkLoad/BASES.csv
Normal file
@@ -0,0 +1,53 @@
|
||||
"CODE","DRWG_CODE","DESCRIPTION","DIM_A","DIM_B","DIM_C","DIM_D","DIM_E","DIM_F","DIM_G","DIM_H","DIM_I","DEPTH"
|
||||
"0","H",,0,0,0,0,0,0,0,0,0,0
|
||||
"CustomB","H",,0,0,0,0,0,0,0,0,0,0
|
||||
"RA0025LPB","H",,950,700,350,80,370,320,80,370,240,100
|
||||
"RA0025MPB","H",,950,700,350,80,335,275,100,345,275,100
|
||||
"RA0040LPB","H",,950,750,350,80,347,297,80,347,297,100
|
||||
"RA0040MPB","H",,1400,950,475,80,417,357,100,427,357,100
|
||||
"RA0065LPB","H",,1900,1150,575,150,790,707,100,760,707,150
|
||||
"RA0100LPB","H",,1900,1150,575,150,790,707,100,760,707,150
|
||||
"RA0100MPB","H",,1625,950,475,100,520,443,100,460,382,100
|
||||
"RA0160LPB","H",,1900,1150,575,150,790,707,150,790,707,150
|
||||
"RA0160MPB","H",,2700,1500,750,100,785,710,150,800,710,150
|
||||
"RA0200LPB","H",,1900,1150,575,150,790,707,150,790,707,150
|
||||
"RA0200MPB","H",,2700,1500,750,100,809,740,150,827,737,150
|
||||
"RA0250+LPB","H",,2700,1500,750,200,910,809,150,900,809,150
|
||||
"RA0250LPB","H",,1900,1150,575,150,790,707,150,790,707,150
|
||||
"RA0250MPB","H",,2700,1500,750,150,820,730,150,820,730,150
|
||||
"RA0300+LPB","H",,3800,2050,1025,250,980,856,200,955,855,150
|
||||
"RA0300LPB","H",,2700,1500,750,200,530,431,200,530,431,150
|
||||
"RA0300MPB","H",,2700,1500,750,150,775,685,200,805,705,150
|
||||
"RA0400LPB","H",,3800,2050,1025,250,990,865,200,964,864,150
|
||||
"RA0400MPB","H",,2700,1500,750,150,775,685,200,805,705,150
|
||||
"RA0650+LPB","H",,4800,3050,1525,250,1137,1012,250,1137,1012,150
|
||||
"RA0650LPB","H",,4300,2300,1150,250,987,862,250,987,862,150
|
||||
"RA0650MPB","H",,3300,2300,1150,200,1010,910,250,1048,923,150
|
||||
"RA1000+LPB","H",,4800,3050,1525,250,1125,1000,250,1125,999,150
|
||||
"RA1000LPB","H",,4300,2300,1150,250,1020,893,250,1020,892,150
|
||||
"RA1000MPB","H",,3300,2300,1150,250,1015,890,250,1020,895,150
|
||||
"RD0025MPB","H",,1400,950,475,80,520,475,100,480,425,100
|
||||
"RD0040MPB","H",,1400,950,475,80,485,440,100,460,410,100
|
||||
"RD0065MPB","H",,1400,950,475,80,485,440,100,465,410,100
|
||||
"RD0100MPB","H",,1400,950,475,80,485,440,100,465,410,100
|
||||
"RD0160MPB","H",,0,0,0,0,0,0,0,0,0,0
|
||||
"RD0250MPB","H",,2700,1500,750,150,844,754,150,844,754,150
|
||||
"RD0310MPB","H",,2700,1500,750,150,835,745,200,850,750,150
|
||||
"RD0450+MPB","C",,3300,2050,1025,925,600,730,400,,,150
|
||||
"RD0450MPB","C",,3300,2050,1025,925,590,748,400,,,150
|
||||
"RD0650MPB","C",,3800,2050,1025,900,625,831,400,,,150
|
||||
"RD1075MPB","C",,4300,2300,1150,1025,650,958,400,,,150
|
||||
"RD1600MPB","C",,4300,2300,1150,1000,725,837,450,,,150
|
||||
"RD2885MPB","C",,0,0,0,0,0,0,0,,,0
|
||||
"U016LPB","H",,950,700,350,80,250,225,80,250,0,100
|
||||
"U016MPB","H",,950,700,350,80,255,220,80,255,0,100
|
||||
"U025LPB","H",,1200,740,370,100,200,140,100,250,0,100
|
||||
"U025MPB","H",,1400,950,475,80,350,300,80,350,0,100
|
||||
"U040LPB","H",,1200,740,370,100,200,140,100,250,0,100
|
||||
"U040MPB","H",,1400,950,475,80,300,250,100,300,0,100
|
||||
"U065LPB","H",,1700,950,475,150,250,190,150,300,0,100
|
||||
"U065MPB","H",,1900,1150,575,100,450,400,100,450,0,150
|
||||
"U100LPB","H",,1900,1150,575,150,450,400,150,400,0,150
|
||||
"U100MPB","H",,1900,1150,575,100,400,350,100,400,0,150
|
||||
"U160LPB","H",,1900,1150,575,200,450,400,200,450,0,150
|
||||
"U160MPB","H",,1900,1150,575,100,350,300,150,375,0,150
|
||||
|
Binary file not shown.
337
Data/BulkLoad/CAVEATS.csv
Normal file
337
Data/BulkLoad/CAVEATS.csv
Normal file
@@ -0,0 +1,337 @@
|
||||
"DOCUMENT_POSITION","ENTY_CODE","METY_CODE","SVCPT_CODE","SORT_ORDER","TEXT"
|
||||
"CONT_SUM","ADVERSARIAL","DIAPHRAGM","LP",1,"plus purging on time and materials basis."
|
||||
"CONT_SUM","ADVERSARIAL","DIAPHRAGM","MP",1,"plus purging on time and materials basis."
|
||||
"CONT_SUM","ADVERSARIAL","ROTARY","LP",1,"plus purging on time and materials basis."
|
||||
"CONT_SUM","ADVERSARIAL","ROTARY","MP",1,"plus purging on time and materials basis."
|
||||
"CONT_SUM","ADVERSARIAL","TURBINE","LP",1,"plus purging on time and materials basis."
|
||||
"CONT_SUM","ADVERSARIAL","TURBINE","MP",1,"plus purging on time and materials basis."
|
||||
"CONT_SUM","STD REMOVE","DIAPHRAGM","LP",1,"plus purging on time and materials basis."
|
||||
"CONT_SUM_QA","ADVERSARIAL","DIAPHRAGM","LP",1,"plus purging on time and materials basis."
|
||||
"CONT_SUM_QA","ADVERSARIAL","DIAPHRAGM","MP",1,"plus purging on time and materials basis."
|
||||
"CONT_SUM_QA","ADVERSARIAL","ROTARY","LP",1,"plus purging on time and materials basis."
|
||||
"CONT_SUM_QA","ADVERSARIAL","ROTARY","MP",1,"plus purging on time and materials basis."
|
||||
"CONT_SUM_QA","ADVERSARIAL","TURBINE","LP",1,"plus purging on time and materials basis."
|
||||
"CONT_SUM_QA","ADVERSARIAL","TURBINE","MP",1,"plus purging on time and materials basis."
|
||||
"CONT_SUM_QA","STD REMOVE","DIAPHRAGM","LP",1,"plus purging on time and materials basis."
|
||||
"DESC_WORK","ADVERSARIAL","DIAPHRAGM","LP",1,"Purging of downstream pipework."
|
||||
"DESC_WORK","ADVERSARIAL","DIAPHRAGM","MP",1,"Purging of downstream pipework."
|
||||
"DESC_WORK","ADVERSARIAL","ROTARY","LP",1,"Purging of downstream pipework."
|
||||
"DESC_WORK","ADVERSARIAL","ROTARY","MP",1,"Purging of downstream pipework."
|
||||
"DESC_WORK","ADVERSARIAL","TURBINE","LP",1,"Purging of downstream pipework."
|
||||
"DESC_WORK","ADVERSARIAL","TURBINE","MP",1,"Purging of downstream pipework."
|
||||
"DESC_WORK","EXCHANGE","DIAPHRAGM","LP",1,"Any service alteration required will need to be actioned by the UIP. Any outlet pipework alterations and the outlet pipework connection to the meter module will need to be actioned by others."
|
||||
"DESC_WORK","EXCHANGE","DIAPHRAGM","MP",1,"Any service alteration required will need to be actioned by the UIP. Any outlet pipework alterations and the outlet pipework connection to the meter module will need to be actioned by others."
|
||||
"DESC_WORK","EXCHANGE","ROTARY","LP",1,"Any service alteration required will need to be actioned by the UIP. Any outlet pipework alterations and the outlet pipework connection to the meter module will need to be actioned by others."
|
||||
"DESC_WORK","EXCHANGE","ROTARY","MP",1,"Any service alteration required will need to be actioned by the UIP. Any outlet pipework alterations and the outlet pipework connection to the meter module will need to be actioned by others."
|
||||
"DESC_WORK","EXCHANGE","TURBINE","LP",1,"Any service alteration required will need to be actioned by the UIP. Any outlet pipework alterations and the outlet pipework connection to the meter module will need to be actioned by others."
|
||||
"DESC_WORK","EXCHANGE","TURBINE","MP",1,"Any service alteration required will need to be actioned by the UIP. Any outlet pipework alterations and the outlet pipework connection to the meter module will need to be actioned by others."
|
||||
"DESC_WORK","REMOVE","DIAPHRAGM","LP",1,"Purging of downstream pipework."
|
||||
"DESC_WORK","REMOVE","DIAPHRAGM","MP",1,"Purging of downstream pipework."
|
||||
"DESC_WORK","REMOVE","ROTARY","LP",1,"Purging of downstream pipework."
|
||||
"DESC_WORK","REMOVE","ROTARY","MP",1,"Purging of downstream pipework."
|
||||
"DESC_WORK","REMOVE","TURBINE","LP",1,"Purging of downstream pipework."
|
||||
"DESC_WORK","REMOVE","TURBINE","MP",1,"Purging of downstream pipework."
|
||||
"DESC_WORK","STD EXCHANGE","DIAPHRAGM","LP",1,"Any service alteration required will need to be actioned by the UIP. Any outlet pipework alterations and the outlet pipework connection to the meter module will need to be actioned by others."
|
||||
"DESC_WORK","STD EXCHANGE","DIAPHRAGM","MP",1,"Any service alteration required will need to be actioned by the UIP. Any outlet pipework alterations and the outlet pipework connection to the meter module will need to be actioned by others."
|
||||
"DESC_WORK","STD EXCHANGE","ROTARY","LP",1,"Any service alteration required will need to be actioned by the UIP. Any outlet pipework alterations and the outlet pipework connection to the meter module will need to be actioned by others."
|
||||
"DESC_WORK","STD EXCHANGE","ROTARY","MP",1,"Any service alteration required will need to be actioned by the UIP. Any outlet pipework alterations and the outlet pipework connection to the meter module will need to be actioned by others."
|
||||
"DESC_WORK","STD EXCHANGE","TURBINE","LP",1,"Any service alteration required will need to be actioned by the UIP. Any outlet pipework alterations and the outlet pipework connection to the meter module will need to be actioned by others."
|
||||
"DESC_WORK","STD EXCHANGE","TURBINE","MP",1,"Any service alteration required will need to be actioned by the UIP. Any outlet pipework alterations and the outlet pipework connection to the meter module will need to be actioned by others."
|
||||
"DESC_WORK","STD REMOVE","DIAPHRAGM","LP",1,"Purging of downstream pipework."
|
||||
"TERM_COND","ADDON","DIAPHRAGM","LP",1,"This quotation is based on there being a working LF connection on the existing meter."
|
||||
"TERM_COND","ADDON","DIAPHRAGM","LP",2,"This quotation does not include for the provision of a separate instrumentation cabinet."
|
||||
"TERM_COND","ADDON","DIAPHRAGM","LP",3,"Electrical Connections to gas meters are subject to the assessment of the hazardous area around the meter. This is largely affected by the ventilation in the housing. Should the ventilation be found to be inadequate the connection will not be made and the requirements to allow the connection reported to you."
|
||||
"TERM_COND","ADDON","DIAPHRAGM","MP",1,"This quotation is based on there being a working LF connection on the existing meter."
|
||||
"TERM_COND","ADDON","DIAPHRAGM","MP",2,"This quotation does not include for the provision of a separate instrumentation cabinet."
|
||||
"TERM_COND","ADDON","DIAPHRAGM","MP",3,"Electrical Connections to gas meters are subject to the assessment of the hazardous area around the meter. This is largely affected by the ventilation in the housing. Should the ventilation be found to be inadequate the connection will not be made and the requirements to allow the connection reported to you."
|
||||
"TERM_COND","ADDON","ROTARY","LP",1,"This quotation is based on there being a working LF connection on the existing meter."
|
||||
"TERM_COND","ADDON","ROTARY","LP",2,"This quotation does not include for the provision of a separate instrumentation cabinet."
|
||||
"TERM_COND","ADDON","ROTARY","LP",3,"Electrical Connections to gas meters are subject to the assessment of the hazardous area around the meter. This is largely affected by the ventilation in the housing. Should the ventilation be found to be inadequate the connection will not be made and the requirements to allow the connection reported to you."
|
||||
"TERM_COND","ADDON","ROTARY","MP",1,"This quotation is based on there being a working LF connection on the existing meter."
|
||||
"TERM_COND","ADDON","ROTARY","MP",2,"This quotation does not include for the provision of a separate instrumentation cabinet."
|
||||
"TERM_COND","ADDON","ROTARY","MP",3,"Electrical Connections to gas meters are subject to the assessment of the hazardous area around the meter. This is largely affected by the ventilation in the housing. Should the ventilation be found to be inadequate the connection will not be made and the requirements to allow the connection reported to you."
|
||||
"TERM_COND","ADDON","TURBINE","LP",1,"This quotation is based on there being a working LF connection on the existing meter."
|
||||
"TERM_COND","ADDON","TURBINE","LP",2,"This quotation does not include for the provision of a separate instrumentation cabinet."
|
||||
"TERM_COND","ADDON","TURBINE","LP",3,"Electrical Connections to gas meters are subject to the assessment of the hazardous area around the meter. This is largely affected by the ventilation in the housing. Should the ventilation be found to be inadequate the connection will not be made and the requirements to allow the connection reported to you."
|
||||
"TERM_COND","ADDON","TURBINE","MP",1,"This quotation is based on there being a working LF connection on the existing meter."
|
||||
"TERM_COND","ADDON","TURBINE","MP",2,"This quotation does not include for the provision of a separate instrumentation cabinet."
|
||||
"TERM_COND","ADDON","TURBINE","MP",3,"Electrical Connections to gas meters are subject to the assessment of the hazardous area around the meter. This is largely affected by the ventilation in the housing. Should the ventilation be found to be inadequate the connection will not be made and the requirements to allow the connection reported to you."
|
||||
"TERM_COND","ADVERSARIAL","DIAPHRAGM","LP",1,"This quotation is based on a low pressure service tier. If the pressure tier if found not to be low pressure, this will be subject to a new quotation or variation and planned meter works will not commence."
|
||||
"TERM_COND","ADVERSARIAL","ROTARY","LP",1,"This quotation is based on a low pressure service tier. If the pressure tier if found not to be low pressure, this will be subject to a new quotation or variation and planned meter works will not commence."
|
||||
"TERM_COND","ADVERSARIAL","ROTARY","LP",2,"Lifting gear if required will be charged at a rate of <20>400 per day."
|
||||
"TERM_COND","ADVERSARIAL","ROTARY","MP",1,"Lifting gear if required will be charged at a rate of <20>400 per day."
|
||||
"TERM_COND","ADVERSARIAL","TURBINE","LP",1,"This quotation is based on a low pressure service tier. If the pressure tier if found not to be low pressure, this will be subject to a new quotation or variation and planned meter works will not commence.
|
||||
"
|
||||
"TERM_COND","ADVERSARIAL","TURBINE","LP",2,"Lifting gear if required will be charged at a rate of <20>400 per day."
|
||||
"TERM_COND","ADVERSARIAL","TURBINE","MP",1,"Lifting gear if required will be charged at a rate of <20>400 per day."
|
||||
"TERM_COND","EXCHANGE","DIAPHRAGM","LP",1,"Please note that all the sizes and dimensions stated are indicative and are based on current practice at the time of quotation. These are subject to change and must be confirmed at placement of order."
|
||||
"TERM_COND","EXCHANGE","DIAPHRAGM","LP",2,"Housings must have a free ventilation area equal to/exceeding 3% floor area. Minimum Housing requirements for this module are: L nnn mm x W nnn mm x H nnn mm . Failure to provide adequate housing will result in the job not being completed."
|
||||
"TERM_COND","EXCHANGE","DIAPHRAGM","LP",3,"Minimum Base dimension requirements for this module are: L nnn mm x W nnn mm x H nnn mm . Failure not to provide accurate base will result in the job not being completed."
|
||||
"TERM_COND","EXCHANGE","DIAPHRAGM","LP",4,"The Supply Point must be suitably sized and positioned to provide a minimum pressure of 25 mbar under Qmax load at the ECV outlet point."
|
||||
"TERM_COND","EXCHANGE","DIAPHRAGM","LP",5,"This quotation is based on a xxxxxx (insert inlet orientation) inlet and xxxxxx (insert outlet orientation) outlet and the ECV being installed to the dimensions provided.
|
||||
|
||||
The meter module is a single stream supply with no bypass facility. During maintenance operations on the meter installation it may be necessary to isolate the supply temporarily."
|
||||
"TERM_COND","EXCHANGE","DIAPHRAGM","LP",6,"It is critical that the module inlet dimensions and orientation are given to the UIP when service works are taken place."
|
||||
"TERM_COND","EXCHANGE","DIAPHRAGM","LP",7,"The proposed meter module has a Qmin of nnn kWh and is based on the requested Qmax of nnn kWh."
|
||||
"TERM_COND","EXCHANGE","DIAPHRAGM","LP",8,"This quotation is based on the exchange being completed on the same day and the new meter module being attached to the existing ECV."
|
||||
"TERM_COND","EXCHANGE","DIAPHRAGM","LP",9,"Please note that this quotation is based on two visits, first visit for the removal and purging of the existing meter module and the second to install a new meter module after the service alteration."
|
||||
"TERM_COND","EXCHANGE","DIAPHRAGM","MP",1,"Please note that all the sizes and dimensions stated are indicative and are based on current practice at the time of quotation. These are subject to change and must be confirmed at placement of order."
|
||||
"TERM_COND","EXCHANGE","DIAPHRAGM","MP",2,"Housings must have a free ventilation area equal to/exceeding 3% floor area. Minimum Housing requirements for this module are: L nnn mm x W nnn mm x H nnn mm . Failure to provide adequate housing will result in the job not being completed."
|
||||
"TERM_COND","EXCHANGE","DIAPHRAGM","MP",3,"Minimum Base dimension requirements for this module are: L nnn mm x W nnn mm x H nnn mm . Failure not to provide accurate base will result in the job not being completed."
|
||||
"TERM_COND","EXCHANGE","DIAPHRAGM","MP",4,"The Supply Point must be suitably sized and positioned to provide a minimum pressure of nnn (insert design minimum pressure) mbar under Qmax load at the ECV outlet point."
|
||||
"TERM_COND","EXCHANGE","DIAPHRAGM","MP",5,"This quotation is based on a xxxxxx (insert inlet orientation) inlet and xxxxxx (insert outlet orientation) outlet and the ECV being installed to the dimensions provided
|
||||
|
||||
The meter module offered is a singlestream supply with only a nominal bypass facility. The bypass is only used during maintenance, and is only sized to maintain gas pressure downstream. Please note that during maintenance it will be necessary to disrupt supplies.
|
||||
"
|
||||
"TERM_COND","EXCHANGE","DIAPHRAGM","MP",6,"It is critical that the module inlet dimensions and orientation are given to the UIP when service works are taken place."
|
||||
"TERM_COND","EXCHANGE","DIAPHRAGM","MP",7,"The proposed meter module has a Qmin of nnn kWh and is based on the requested Qmax of nnn kWh."
|
||||
"TERM_COND","EXCHANGE","DIAPHRAGM","MP",8,"This quotation is based on the exchange being completed on the same day and the new meter module being attached to the existing ECV."
|
||||
"TERM_COND","EXCHANGE","DIAPHRAGM","MP",9,"Please note that this quotation is based on two visits, first visit for the removal and purging of the existing meter module and the second to install a new meter module after the service alteration."
|
||||
"TERM_COND","EXCHANGE","ROTARY","LP",1,"Please note that all the sizes and dimensions stated are indicative and are based on current practice at the time of quotation. These are subject to change and must be confirmed at placement of order."
|
||||
"TERM_COND","EXCHANGE","ROTARY","LP",2,"Housings must have a free ventilation area equal to/exceeding 3% floor area. Minimum Housing requirements for this module are: L nnn mm x W nnn mm x H nnn mm . Failure to provide adequate housing will result in the job not being completed."
|
||||
"TERM_COND","EXCHANGE","ROTARY","LP",3,"Minimum Base dimension requirements for this module are: L nnn mm x W nnn mm x H nnn mm . Failure not to provide accurate base will result in the job not being completed."
|
||||
"TERM_COND","EXCHANGE","ROTARY","LP",4,"The Supply Point must be suitably sized and positioned to provide a minimum pressure of 25 mbar under Qmax load at the ECV outlet point."
|
||||
"TERM_COND","EXCHANGE","ROTARY","LP",5,"This quotation is based on a xxxxxx (insert inlet orientation) inlet and xxxxxx (insert outlet orientation) outlet and the ECV being installed to the dimensions provided
|
||||
|
||||
The meter module is a single stream supply with no bypass facility. During maintenance operations on the meter installation it may be necessary to isolate the supply temporarily."
|
||||
"TERM_COND","EXCHANGE","ROTARY","LP",6,"It is critical that the module inlet dimensions and orientation are given to the UIP when service works are taken place."
|
||||
"TERM_COND","EXCHANGE","ROTARY","LP",7,"The proposed meter module has a Qmin of nnn kWh and is based on the requested Qmax of nnn kWh."
|
||||
"TERM_COND","EXCHANGE","ROTARY","LP",8,"This quotation is based on the exchange being completed on the same day and the new meter module being attached to the existing ECV."
|
||||
"TERM_COND","EXCHANGE","ROTARY","LP",9,"Please note that this quotation is based on two visits, first visit for the removal and purging of the existing meter module and the second to install a new meter module after the service alteration."
|
||||
"TERM_COND","EXCHANGE","ROTARY","MP",1,"Please note that all the sizes and dimensions stated are indicative and are based on current practice at the time of quotation. These are subject to change and must be confirmed at placement of order."
|
||||
"TERM_COND","EXCHANGE","ROTARY","MP",2,"Housings must have a free ventilation area equal to/exceeding 3% floor area. Minimum Housing requirements for this module are: L nnn mm x W nnn mm x H nnn mm . Failure to provide adequate housing will result in the job not being completed."
|
||||
"TERM_COND","EXCHANGE","ROTARY","MP",3,"Minimum Base dimension requirements for this module are: L nnn mm x W nnn mm x H nnn mm . Failure not to provide accurate base will result in the job not being completed."
|
||||
"TERM_COND","EXCHANGE","ROTARY","MP",4,"The Supply Point must be suitably sized and positioned to provide a minimum pressure of nnn (insert design minimum pressure) mbar under Qmax load at the ECV outlet point."
|
||||
"TERM_COND","EXCHANGE","ROTARY","MP",5,"This quotation is based on a xxxxxx (insert inlet orientation) inlet and xxxxxx (insert outlet orientation) outlet and the ECV being installed to the dimensions provided
|
||||
|
||||
The meter module offered is a single stream supply with only a nominal bypass facility. The bypass is only used during maintenance, and is only sized to maintain gas pressure downstream. Please note that during maintenance it will be necessary to disrupt supplies."
|
||||
"TERM_COND","EXCHANGE","ROTARY","MP",6,"It is critical that the module inlet dimensions and orientation are given to the UIP when service works are taken place."
|
||||
"TERM_COND","EXCHANGE","ROTARY","MP",7,"The proposed meter module has a Qmin of nnn kWh and is based on the requested Qmax of nnn kWh."
|
||||
"TERM_COND","EXCHANGE","ROTARY","MP",8,"This quotation is based on the exchange being completed on the same day and the new meter module being attached to the existing ECV."
|
||||
"TERM_COND","EXCHANGE","ROTARY","MP",9,"Please note that this quotation is based on two visits, first visit for the removal and purging of the existing meter module and the second to install a new meter module after the service alteration."
|
||||
"TERM_COND","EXCHANGE","TURBINE","LP",1,"Please note that all the sizes and dimensions stated are indicative and are based on current practice at the time of quotation. These are subject to change and must be confirmed at placement of order."
|
||||
"TERM_COND","EXCHANGE","TURBINE","LP",2,"Housings must have a free ventilation area equal to/exceeding 3% floor area. Minimum Housing requirements for this module are: L nnn mm x W nnn mm x H nnn mm . Failure to provide adequate housing will result in the job not being completed."
|
||||
"TERM_COND","EXCHANGE","TURBINE","LP",3,"Minimum Base dimension requirements for this module are: L nnn mm x W nnn mm x H nnn mm . Failure not to provide accurate base will result in the job not being completed."
|
||||
"TERM_COND","EXCHANGE","TURBINE","LP",4,"The Supply Point must be suitably sized and positioned to provide a minimum pressure of 25 mbar under Qmax load at the ECV outlet point."
|
||||
"TERM_COND","EXCHANGE","TURBINE","LP",5,"This quotation is based on a xxxxxx (insert inlet orientation) inlet and xxxxxx (insert outlet orientation) outlet and the ECV being installed to the dimensions provided
|
||||
|
||||
The meter module is a single stream supply with no bypass facility. During maintenance operations on the meter installation it may be necessary to isolate the supply temporarily."
|
||||
"TERM_COND","EXCHANGE","TURBINE","LP",6,"It is critical that the module inlet dimensions and orientation are given to the UIP when service works are taken place."
|
||||
"TERM_COND","EXCHANGE","TURBINE","LP",7,"The proposed meter module has a Qmin of nnn kWh and is based on the requested Qmax of nnn kWh."
|
||||
"TERM_COND","EXCHANGE","TURBINE","LP",8,"This quotation is based on the exchange being completed on the same day and the new meter module being attached to the existing ECV."
|
||||
"TERM_COND","EXCHANGE","TURBINE","LP",9,"Please note that this quotation is based on two visits, first visit for the removal and purging of the existing meter module and the second to install a new meter module after the service alteration."
|
||||
"TERM_COND","EXCHANGE","TURBINE","MP",1,"Please note that all the sizes and dimensions stated are indicative and are based on current practice at the time of quotation. These are subject to change and must be confirmed at placement of order."
|
||||
"TERM_COND","EXCHANGE","TURBINE","MP",2,"Housings must have a free ventilation area equal to/exceeding 3% floor area. Minimum Housing requirements for this module are: L nnn mm x W nnn mm x H nnn mm . Failure to provide adequate housing will result in the job not being completed."
|
||||
"TERM_COND","EXCHANGE","TURBINE","MP",3,"Minimum Base dimension requirements for this module are: L nnn mm x W nnn mm x H nnn mm . Failure not to provide accurate base will result in the job not being completed
|
||||
"
|
||||
"TERM_COND","EXCHANGE","TURBINE","MP",4,"The Supply Point must be suitably sized and positioned to provide a minimum pressure of nnn (insert design minimum pressure) mbar under Qmax load at the ECV outlet point."
|
||||
"TERM_COND","EXCHANGE","TURBINE","MP",5,"This quotation is based on a xxxxxx (insert inlet orientation) inlet and xxxxxx (insert outlet orientation) outlet and the ECV being installed to the dimensions provided
|
||||
|
||||
The meter module offered is a single stream supply with only a nominal bypass facility. The bypass is only used during maintenance, and is only sized to maintain gas pressure downstream. Please note that during maintenance it will be necessary to disrupt supplies."
|
||||
"TERM_COND","EXCHANGE","TURBINE","MP",6,"It is critical that the module inlet dimensions and orientation are given to the UIP when service works are taken place."
|
||||
"TERM_COND","EXCHANGE","TURBINE","MP",7,"The proposed meter module has a Qmin of nnn kWh and is based on the requested Qmax of nnn kWh."
|
||||
"TERM_COND","EXCHANGE","TURBINE","MP",8,"This quotation is based on the exchange being completed on the same day and the new meter module being attached to the existing ECV."
|
||||
"TERM_COND","EXCHANGE","TURBINE","MP",9,"Please note that this quotation is based on two visits, first visit for the removal and purging of the existing meter module and the second to install a new meter module after the service alteration."
|
||||
"TERM_COND","INSTALL","DIAPHRAGM","LP",1,"Please note that all the sizes and dimensions stated are indicative and are based on current practice at the time of quotation. These are subject to change and must be confirmed at placement of order."
|
||||
"TERM_COND","INSTALL","DIAPHRAGM","LP",2,"Housings must have a free ventilation area equal to/exceeding 3% floor area. Minimum Housing requirements for this module are: L nnn mm x W nnn mm x H nnn mm . Failure to provide adequate housing will result in the job not being completed."
|
||||
"TERM_COND","INSTALL","DIAPHRAGM","LP",3,"Minimum Base dimension requirements for this module are: L nnn mm x W nnn mm x H nnn mm . Failure not to provide accurate base will result in the job not being completed."
|
||||
"TERM_COND","INSTALL","DIAPHRAGM","LP",4,"The Supply Point must be suitably sized and positioned to provide a minimum pressure of 25 mbar under Qmax load at the ECV outlet point."
|
||||
"TERM_COND","INSTALL","DIAPHRAGM","LP",5,"This quotation is based on a xxxxxx (insert inlet orientation) inlet and xxxxxx (insert outlet orientation) outlet and the ECV being installed to the dimensions provided
|
||||
|
||||
The meter module is a single stream supply with no bypass facility. During maintenance operations on the meter installation it may be necessary to isolate the supply temporarily."
|
||||
"TERM_COND","INSTALL","DIAPHRAGM","LP",6,"It is critical that the module inlet dimensions and orientation are given to the UIP when service works are taken place."
|
||||
"TERM_COND","INSTALL","DIAPHRAGM","LP",7,"The proposed meter module has a Qmin of nnn kWh and is based on the requested Qmax of nnn kWh.
|
||||
"
|
||||
"TERM_COND","INSTALL","DIAPHRAGM","MP",1,"Please note that all the sizes and dimensions stated are indicative and are based on current practice at the time of quotation. These are subject to change and must be confirmed at placement of order."
|
||||
"TERM_COND","INSTALL","DIAPHRAGM","MP",2,"Housings must have a free ventilation area equal to/exceeding 3% floor area. Minimum Housing requirements for this module are: L nnn mm x W nnn mm x H nnn mm . Failure to provide adequate housing will result in the job not being completed."
|
||||
"TERM_COND","INSTALL","DIAPHRAGM","MP",3,"Minimum Base dimension requirements for this module are: L nnn mm x W nnn mm x H nnn mm . Failure not to provide accurate base will result in the job not being completed."
|
||||
"TERM_COND","INSTALL","DIAPHRAGM","MP",4,"The Supply Point must be suitably sized and positioned to provide a minimum pressure of nnn (insert design minimum pressure) mbar under Qmax load at the ECV outlet point."
|
||||
"TERM_COND","INSTALL","DIAPHRAGM","MP",5,"This quotation is based on a xxxxxx (insert inlet orientation) inlet and xxxxxx (insert outlet orientation) outlet and the ECV being installed to the dimensions provided
|
||||
|
||||
The meter module offered is a xxxx (twin/single) stream supply with only a nominal bypass facility. The bypass is only used during maintenance, and is only sized to maintain gas pressure downstream. Please note that during maintenance it will be necessary to disrupt supplies."
|
||||
"TERM_COND","INSTALL","DIAPHRAGM","MP",6,"It is critical that the module inlet dimensions and orientation are given to the UIP when service works are taken place."
|
||||
"TERM_COND","INSTALL","DIAPHRAGM","MP",7,"The proposed meter module has a Qmin of nnn kWh and is based on the requested Qmax of nnn kWh."
|
||||
"TERM_COND","INSTALL","ROTARY","LP",1,"Please note that all the sizes and dimensions stated are indicative and are based on current practice at the time of quotation. These are subject to change and must be confirmed at placement of order."
|
||||
"TERM_COND","INSTALL","ROTARY","LP",2,"Housings must have a free ventilation area equal to/exceeding 3% floor area. Minimum Housing requirements for this module are: L nnn mm x W nnn mm x H nnn mm . Failure to provide adequate housing will result in the job not being completed."
|
||||
"TERM_COND","INSTALL","ROTARY","LP",3,"Minimum Base dimension requirements for this module are: L nnn mm x W nnn mm x H nnn mm . Failure not to provide accurate base will result in the job not being completed."
|
||||
"TERM_COND","INSTALL","ROTARY","LP",4,"The Supply Point must be suitably sized and positioned to provide a minimum pressure of 25 mbar under Qmax load at the ECV outlet point."
|
||||
"TERM_COND","INSTALL","ROTARY","LP",5,"This quotation is based on a xxxxxx (insert inlet orientation) inlet and xxxxxx (insert outlet orientation) outlet and the ECV being installed to the dimensions provided
|
||||
|
||||
The meter module is a single stream supply with no bypass facility. During maintenance operations on the meter installation it may be necessary to isolate the supply temporarily."
|
||||
"TERM_COND","INSTALL","ROTARY","LP",6,"It is critical that the module inlet dimensions and orientation are given to the UIP when service works are taken place."
|
||||
"TERM_COND","INSTALL","ROTARY","LP",7,"The proposed meter module has a Qmin of nnn kWh and is based on the requested Qmax of nnn kWh."
|
||||
"TERM_COND","INSTALL","ROTARY","MP",1,"Please note that all the sizes and dimensions stated are indicative and are based on current practice at the time of quotation. These are subject to change and must be confirmed at placement of order."
|
||||
"TERM_COND","INSTALL","ROTARY","MP",2,"Housings must have a free ventilation area equal to/exceeding 3% floor area. Minimum Housing requirements for this module are: L nnn mm x W nnn mm x H nnn mm . Failure to provide adequate housing will result in the job not being completed."
|
||||
"TERM_COND","INSTALL","ROTARY","MP",3,"Minimum Base dimension requirements for this module are: L nnn mm x W nnn mm x H nnn mm . Failure not to provide accurate base will result in the job not being completed."
|
||||
"TERM_COND","INSTALL","ROTARY","MP",4,"The Supply Point must be suitably sized and positioned to provide a minimum pressure of nnn (insert design minimum pressure) mbar under Qmax load at the ECV outlet point."
|
||||
"TERM_COND","INSTALL","ROTARY","MP",5,"This quotation is based on a xxxxxx (insert inlet orientation) inlet and xxxxxx (insert outlet orientation) outlet and the ECV being installed to the dimensions provided
|
||||
|
||||
The meter module offered is a xxxx (twin/single) stream supply with only a nominal bypass facility. The bypass is only used during maintenance, and is only sized to maintain gas pressure downstream. Please note that during maintenance it will be necessary to disrupt supplies."
|
||||
"TERM_COND","INSTALL","ROTARY","MP",6,"It is critical that the module inlet dimensions and orientation are given to the UIP when service works are taken place."
|
||||
"TERM_COND","INSTALL","ROTARY","MP",7,"The proposed meter module has a Qmin of nnn kWh and is based on the requested Qmax of nnn kWh."
|
||||
"TERM_COND","INSTALL","TURBINE","LP",1,"Please note that all the sizes and dimensions stated are indicative and are based on current practice at the time of quotation. These are subject to change and must be confirmed at placement of order."
|
||||
"TERM_COND","INSTALL","TURBINE","LP",2,"Housings must have a free ventilation area equal to/exceeding 3% floor area. Minimum Housing requirements for this module are: L nnn mm x W nnn mm x H nnn mm . Failure to provide adequate housing will result in the job not being completed."
|
||||
"TERM_COND","INSTALL","TURBINE","LP",3,"Minimum Base dimension requirements for this module are: L nnn mm x W nnn mm x H nnn mm . Failure not to provide accurate base will result in the job not being completed.
|
||||
"
|
||||
"TERM_COND","INSTALL","TURBINE","LP",4,"The Supply Point must be suitably sized and positioned to provide a minimum pressure of 25 mbar under Qmax load at the ECV outlet point."
|
||||
"TERM_COND","INSTALL","TURBINE","LP",5,"This quotation is based on a xxxxxx (insert inlet orientation) inlet and xxxxxx (insert outlet orientation) outlet and the ECV being installed to the dimensions provided
|
||||
|
||||
The meter module is a single stream supply with no bypass facility. During maintenance operations on the meter installation it may be necessary to isolate the supply temporarily."
|
||||
"TERM_COND","INSTALL","TURBINE","LP",6,"It is critical that the module inlet dimensions and orientation are given to the UIP when service works are taken place."
|
||||
"TERM_COND","INSTALL","TURBINE","LP",7,"The proposed meter module has a Qmin of nnn kWh and is based on the requested Qmax of nnn kWh."
|
||||
"TERM_COND","INSTALL","TURBINE","MP",1,"Please note that all the sizes and dimensions stated are indicative and are based on current practice at the time of quotation. These are subject to change and must be confirmed at placement of order."
|
||||
"TERM_COND","INSTALL","TURBINE","MP",2,"Housings must have a free ventilation area equal to/exceeding 3% floor area. Minimum Housing requirements for this module are: L nnn mm x W nnn mm x H nnn mm . Failure to provide adequate housing will result in the job not being completed."
|
||||
"TERM_COND","INSTALL","TURBINE","MP",3,"Minimum Base dimension requirements for this module are: L nnn mm x W nnn mm x H nnn mm . Failure not to provide accurate base will result in the job not being completed.
|
||||
"
|
||||
"TERM_COND","INSTALL","TURBINE","MP",4,"The Supply Point must be suitably sized and positioned to provide a minimum pressure of nnn (insert design minimum pressure) mbar under Qmax load at the ECV outlet point."
|
||||
"TERM_COND","INSTALL","TURBINE","MP",5,"This quotation is based on a xxxxxx (insert inlet orientation) inlet and xxxxxx (insert outlet orientation) outlet and the ECV being installed to the dimensions provided
|
||||
|
||||
The meter module offered is a xxxx (twin/single) stream supply with only a nominal bypass facility. The bypass is only used during maintenance, and is only sized to maintain gas pressure downstream. Please note that during maintenance it will be necessary to disrupt supplies.
|
||||
"
|
||||
"TERM_COND","INSTALL","TURBINE","MP",6,"It is critical that the module inlet dimensions and orientation are given to the UIP when service works are taken place."
|
||||
"TERM_COND","INSTALL","TURBINE","MP",7,"The proposed meter module has a Qmin of nnn kWh and is based on the requested Qmax of nnn kWh."
|
||||
"TERM_COND","OFMAT","DIAPHRAGM","LP",1,"This charge will only be applicable if the meter accuracy test identifies the meter to be working correctly."
|
||||
"TERM_COND","OFMAT","DIAPHRAGM","MP",1,"This charge will only be applicable if the meter accuracy test identifies the meter to be working correctly."
|
||||
"TERM_COND","OFMAT","ROTARY","LP",1,"This charge will only be applicable if the meter accuracy test identifies the meter to be working correctly."
|
||||
"TERM_COND","OFMAT","ROTARY","MP",1,"This charge will only be applicable if the meter accuracy test identifies the meter to be working correctly."
|
||||
"TERM_COND","OFMAT","TURBINE","LP",1,"This charge will only be applicable if the meter accuracy test identifies the meter to be working correctly."
|
||||
"TERM_COND","OFMAT","TURBINE","MP",1,"This charge will only be applicable if the meter accuracy test identifies the meter to be working correctly."
|
||||
"TERM_COND","REMOVE","DIAPHRAGM","LP",1,"This quotation is based on a low pressure service tier. If the pressure tier if found not to be low pressure, this will be subject to a new quotation or variation and planned meter works will not commence.
|
||||
"
|
||||
"TERM_COND","REMOVE","DIAPHRAGM","LP",2,"Where purging of downstream supplies is necessary but has not been requested as part of the meter removal work, the meter will not be removed until the downstream supplies have been made safe by purging."
|
||||
"TERM_COND","REMOVE","DIAPHRAGM","MP",1,"Where purging of downstream supplies is necessary but has not been requested as part of the meter removal work, the meter will not be removed until the downstream supplies have been made safe by purging."
|
||||
"TERM_COND","REMOVE","ROTARY","LP",1,"This quotation is based on a low pressure service tier. If the pressure tier if found not to be low pressure, this will be subject to a new quotation or variation and planned meter works will not commence."
|
||||
"TERM_COND","REMOVE","ROTARY","LP",2,"Where purging of downstream supplies is necessary but has not been requested as part of the meter removal work, the meter will not be removed until the downstream supplies have been made safe by purging."
|
||||
"TERM_COND","REMOVE","ROTARY","MP",1,"Where purging of downstream supplies is necessary but has not been requested as part of the meter removal work, the meter will not be removed until the downstream supplies have been made safe by purging."
|
||||
"TERM_COND","REMOVE","TURBINE","LP",1,"This quotation is based on a low pressure service tier. If the pressure tier if found not to be low pressure, this will be subject to a new quotation or variation and planned meter works will not commence."
|
||||
"TERM_COND","REMOVE","TURBINE","LP",2,"Where purging of downstream supplies is necessary but has not been requested as part of the meter removal work, the meter will not be removed until the downstream supplies have been made safe by purging."
|
||||
"TERM_COND","REMOVE","TURBINE","LP",2,"Where purging of downstream supplies is necessary but has not been requested as part of the meter removal work, the meter will not be removed until the downstream supplies have been made safe by purging."
|
||||
"TERM_COND","REMOVE","TURBINE","MP",1,"Where purging of downstream supplies is necessary but has not been requested as part of the meter removal work, the meter will not be removed until the downstream supplies have been made safe by purging."
|
||||
"TERM_COND","STD EXCHANGE","DIAPHRAGM","LP",1,"Please note that all the sizes and dimensions stated are indicative and are based on current practice at the time of quotation. These are subject to change and must be confirmed at placement of order."
|
||||
"TERM_COND","STD EXCHANGE","DIAPHRAGM","LP",2,"Housings must have a free ventilation area equal to/exceeding 3% floor area. Minimum Housing requirements for this module are: L nnn mm x W nnn mm x H nnn mm . Failure to provide adequate housing will result in the job not being completed."
|
||||
"TERM_COND","STD EXCHANGE","DIAPHRAGM","LP",3,"Minimum Base dimension requirements for this module are: L nnn mm x W nnn mm x H nnn mm . Failure not to provide accurate base will result in the job not being completed."
|
||||
"TERM_COND","STD EXCHANGE","DIAPHRAGM","LP",4,"The Supply Point must be suitably sized and positioned to provide a minimum pressure of 25 mbar under Qmax load at the ECV outlet point."
|
||||
"TERM_COND","STD EXCHANGE","DIAPHRAGM","LP",5,"This quotation is based on a xxxxxx (insert inlet orientation) inlet and xxxxxx (insert outlet orientation) outlet and the ECV being installed to the dimensions provided.
|
||||
|
||||
The meter module is a single stream supply with no bypass facility. During maintenance operations on the meter installation it may be necessary to isolate the supply temporarily."
|
||||
"TERM_COND","STD EXCHANGE","DIAPHRAGM","LP",6,"It is critical that the module inlet dimensions and orientation are given to the UIP when service works are taken place."
|
||||
"TERM_COND","STD EXCHANGE","DIAPHRAGM","LP",7,"The proposed meter module has a Qmin of nnn kWh and is based on the requested Qmax of nnn kWh."
|
||||
"TERM_COND","STD EXCHANGE","DIAPHRAGM","LP",8,"This quotation is based on the exchange being completed on the same day and the new meter module being attached to the existing ECV."
|
||||
"TERM_COND","STD EXCHANGE","DIAPHRAGM","LP",9,"Please note that this quotation is based on two visits, first visit for the removal and purging of the existing meter module and the second to install a new meter module after the service alteration."
|
||||
"TERM_COND","STD EXCHANGE","DIAPHRAGM","MP",1,"Please note that all the sizes and dimensions stated are indicative and are based on current practice at the time of quotation. These are subject to change and must be confirmed at placement of order."
|
||||
"TERM_COND","STD EXCHANGE","DIAPHRAGM","MP",2,"Housings must have a free ventilation area equal to/exceeding 3% floor area. Minimum Housing requirements for this module are: L nnn mm x W nnn mm x H nnn mm . Failure to provide adequate housing will result in the job not being completed."
|
||||
"TERM_COND","STD EXCHANGE","DIAPHRAGM","MP",3,"Minimum Base dimension requirements for this module are: L nnn mm x W nnn mm x H nnn mm . Failure not to provide accurate base will result in the job not being completed."
|
||||
"TERM_COND","STD EXCHANGE","DIAPHRAGM","MP",4,"The Supply Point must be suitably sized and positioned to provide a minimum pressure of nnn (insert design minimum pressure) mbar under Qmax load at the ECV outlet point."
|
||||
"TERM_COND","STD EXCHANGE","DIAPHRAGM","MP",5,"This quotation is based on a xxxxxx (insert inlet orientation) inlet and xxxxxx (insert outlet orientation) outlet and the ECV being installed to the dimensions provided
|
||||
|
||||
The meter module offered is a singlestream supply with only a nominal bypass facility. The bypass is only used during maintenance, and is only sized to maintain gas pressure downstream. Please note that during maintenance it will be necessary to disrupt supplies.
|
||||
"
|
||||
"TERM_COND","STD EXCHANGE","DIAPHRAGM","MP",6,"It is critical that the module inlet dimensions and orientation are given to the UIP when service works are taken place."
|
||||
"TERM_COND","STD EXCHANGE","DIAPHRAGM","MP",7,"The proposed meter module has a Qmin of nnn kWh and is based on the requested Qmax of nnn kWh."
|
||||
"TERM_COND","STD EXCHANGE","DIAPHRAGM","MP",8,"This quotation is based on the exchange being completed on the same day and the new meter module being attached to the existing ECV."
|
||||
"TERM_COND","STD EXCHANGE","DIAPHRAGM","MP",9,"Please note that this quotation is based on two visits, first visit for the removal and purging of the existing meter module and the second to install a new meter module after the service alteration."
|
||||
"TERM_COND","STD EXCHANGE","ROTARY","LP",1,"Please note that all the sizes and dimensions stated are indicative and are based on current practice at the time of quotation. These are subject to change and must be confirmed at placement of order."
|
||||
"TERM_COND","STD EXCHANGE","ROTARY","LP",2,"Housings must have a free ventilation area equal to/exceeding 3% floor area. Minimum Housing requirements for this module are: L nnn mm x W nnn mm x H nnn mm . Failure to provide adequate housing will result in the job not being completed."
|
||||
"TERM_COND","STD EXCHANGE","ROTARY","LP",3,"Minimum Base dimension requirements for this module are: L nnn mm x W nnn mm x H nnn mm . Failure not to provide accurate base will result in the job not being completed."
|
||||
"TERM_COND","STD EXCHANGE","ROTARY","LP",4,"The Supply Point must be suitably sized and positioned to provide a minimum pressure of 25 mbar under Qmax load at the ECV outlet point."
|
||||
"TERM_COND","STD EXCHANGE","ROTARY","LP",5,"This quotation is based on a xxxxxx (insert inlet orientation) inlet and xxxxxx (insert outlet orientation) outlet and the ECV being installed to the dimensions provided
|
||||
|
||||
The meter module is a single stream supply with no bypass facility. During maintenance operations on the meter installation it may be necessary to isolate the supply temporarily."
|
||||
"TERM_COND","STD EXCHANGE","ROTARY","LP",6,"It is critical that the module inlet dimensions and orientation are given to the UIP when service works are taken place."
|
||||
"TERM_COND","STD EXCHANGE","ROTARY","LP",7,"The proposed meter module has a Qmin of nnn kWh and is based on the requested Qmax of nnn kWh."
|
||||
"TERM_COND","STD EXCHANGE","ROTARY","LP",8,"This quotation is based on the exchange being completed on the same day and the new meter module being attached to the existing ECV."
|
||||
"TERM_COND","STD EXCHANGE","ROTARY","LP",9,"Please note that this quotation is based on two visits, first visit for the removal and purging of the existing meter module and the second to install a new meter module after the service alteration."
|
||||
"TERM_COND","STD EXCHANGE","ROTARY","MP",1,"Please note that all the sizes and dimensions stated are indicative and are based on current practice at the time of quotation. These are subject to change and must be confirmed at placement of order."
|
||||
"TERM_COND","STD EXCHANGE","ROTARY","MP",2,"Housings must have a free ventilation area equal to/exceeding 3% floor area. Minimum Housing requirements for this module are: L nnn mm x W nnn mm x H nnn mm . Failure to provide adequate housing will result in the job not being completed."
|
||||
"TERM_COND","STD EXCHANGE","ROTARY","MP",3,"Minimum Base dimension requirements for this module are: L nnn mm x W nnn mm x H nnn mm . Failure not to provide accurate base will result in the job not being completed."
|
||||
"TERM_COND","STD EXCHANGE","ROTARY","MP",4,"The Supply Point must be suitably sized and positioned to provide a minimum pressure of nnn (insert design minimum pressure) mbar under Qmax load at the ECV outlet point."
|
||||
"TERM_COND","STD EXCHANGE","ROTARY","MP",5,"This quotation is based on a xxxxxx (insert inlet orientation) inlet and xxxxxx (insert outlet orientation) outlet and the ECV being installed to the dimensions provided
|
||||
|
||||
The meter module offered is a single stream supply with only a nominal bypass facility. The bypass is only used during maintenance, and is only sized to maintain gas pressure downstream. Please note that during maintenance it will be necessary to disrupt supplies."
|
||||
"TERM_COND","STD EXCHANGE","ROTARY","MP",6,"It is critical that the module inlet dimensions and orientation are given to the UIP when service works are taken place."
|
||||
"TERM_COND","STD EXCHANGE","ROTARY","MP",7,"The proposed meter module has a Qmin of nnn kWh and is based on the requested Qmax of nnn kWh."
|
||||
"TERM_COND","STD EXCHANGE","ROTARY","MP",8,"This quotation is based on the exchange being completed on the same day and the new meter module being attached to the existing ECV."
|
||||
"TERM_COND","STD EXCHANGE","ROTARY","MP",9,"Please note that this quotation is based on two visits, first visit for the removal and purging of the existing meter module and the second to install a new meter module after the service alteration."
|
||||
"TERM_COND","STD EXCHANGE","TURBINE","LP",1,"Please note that all the sizes and dimensions stated are indicative and are based on current practice at the time of quotation. These are subject to change and must be confirmed at placement of order."
|
||||
"TERM_COND","STD EXCHANGE","TURBINE","LP",2,"Housings must have a free ventilation area equal to/exceeding 3% floor area. Minimum Housing requirements for this module are: L nnn mm x W nnn mm x H nnn mm . Failure to provide adequate housing will result in the job not being completed."
|
||||
"TERM_COND","STD EXCHANGE","TURBINE","LP",3,"Minimum Base dimension requirements for this module are: L nnn mm x W nnn mm x H nnn mm . Failure not to provide accurate base will result in the job not being completed."
|
||||
"TERM_COND","STD EXCHANGE","TURBINE","LP",4,"The Supply Point must be suitably sized and positioned to provide a minimum pressure of 25 mbar under Qmax load at the ECV outlet point."
|
||||
"TERM_COND","STD EXCHANGE","TURBINE","LP",5,"This quotation is based on a xxxxxx (insert inlet orientation) inlet and xxxxxx (insert outlet orientation) outlet and the ECV being installed to the dimensions provided
|
||||
|
||||
The meter module is a single stream supply with no bypass facility. During maintenance operations on the meter installation it may be necessary to isolate the supply temporarily."
|
||||
"TERM_COND","STD EXCHANGE","TURBINE","LP",6,"It is critical that the module inlet dimensions and orientation are given to the UIP when service works are taken place."
|
||||
"TERM_COND","STD EXCHANGE","TURBINE","LP",7,"The proposed meter module has a Qmin of nnn kWh and is based on the requested Qmax of nnn kWh."
|
||||
"TERM_COND","STD EXCHANGE","TURBINE","LP",8,"This quotation is based on the exchange being completed on the same day and the new meter module being attached to the existing ECV."
|
||||
"TERM_COND","STD EXCHANGE","TURBINE","LP",9,"Please note that this quotation is based on two visits, first visit for the removal and purging of the existing meter module and the second to install a new meter module after the service alteration."
|
||||
"TERM_COND","STD EXCHANGE","TURBINE","MP",1,"Please note that all the sizes and dimensions stated are indicative and are based on current practice at the time of quotation. These are subject to change and must be confirmed at placement of order."
|
||||
"TERM_COND","STD EXCHANGE","TURBINE","MP",2,"Housings must have a free ventilation area equal to/exceeding 3% floor area. Minimum Housing requirements for this module are: L nnn mm x W nnn mm x H nnn mm . Failure to provide adequate housing will result in the job not being completed."
|
||||
"TERM_COND","STD EXCHANGE","TURBINE","MP",3,"Minimum Base dimension requirements for this module are: L nnn mm x W nnn mm x H nnn mm . Failure not to provide accurate base will result in the job not being completed
|
||||
"
|
||||
"TERM_COND","STD EXCHANGE","TURBINE","MP",4,"The Supply Point must be suitably sized and positioned to provide a minimum pressure of nnn (insert design minimum pressure) mbar under Qmax load at the ECV outlet point."
|
||||
"TERM_COND","STD EXCHANGE","TURBINE","MP",5,"This quotation is based on a xxxxxx (insert inlet orientation) inlet and xxxxxx (insert outlet orientation) outlet and the ECV being installed to the dimensions provided
|
||||
|
||||
The meter module offered is a single stream supply with only a nominal bypass facility. The bypass is only used during maintenance, and is only sized to maintain gas pressure downstream. Please note that during maintenance it will be necessary to disrupt supplies."
|
||||
"TERM_COND","STD EXCHANGE","TURBINE","MP",6,"It is critical that the module inlet dimensions and orientation are given to the UIP when service works are taken place."
|
||||
"TERM_COND","STD EXCHANGE","TURBINE","MP",7,"The proposed meter module has a Qmin of nnn kWh and is based on the requested Qmax of nnn kWh."
|
||||
"TERM_COND","STD EXCHANGE","TURBINE","MP",8,"This quotation is based on the exchange being completed on the same day and the new meter module being attached to the existing ECV."
|
||||
"TERM_COND","STD EXCHANGE","TURBINE","MP",9,"Please note that this quotation is based on two visits, first visit for the removal and purging of the existing meter module and the second to install a new meter module after the service alteration."
|
||||
"TERM_COND","STD INSTALL","DIAPHRAGM","LP",1,"Please note that all the sizes and dimensions stated are indicative and are based on current practice at the time of quotation. These are subject to change and must be confirmed at placement of order."
|
||||
"TERM_COND","STD INSTALL","DIAPHRAGM","LP",2,"Housings must have a free ventilation area equal to/exceeding 3% floor area. Minimum Housing requirements for this module are: L nnn mm x W nnn mm x H nnn mm . Failure to provide adequate housing will result in the job not being completed."
|
||||
"TERM_COND","STD INSTALL","DIAPHRAGM","LP",3,"Minimum Base dimension requirements for this module are: L nnn mm x W nnn mm x H nnn mm . Failure not to provide accurate base will result in the job not being completed."
|
||||
"TERM_COND","STD INSTALL","DIAPHRAGM","LP",4,"The Supply Point must be suitably sized and positioned to provide a minimum pressure of 25 mbar under Qmax load at the ECV outlet point."
|
||||
"TERM_COND","STD INSTALL","DIAPHRAGM","LP",5,"This quotation is based on a xxxxxx (insert inlet orientation) inlet and xxxxxx (insert outlet orientation) outlet and the ECV being installed to the dimensions provided
|
||||
|
||||
The meter module is a single stream supply with no bypass facility. During maintenance operations on the meter installation it may be necessary to isolate the supply temporarily."
|
||||
"TERM_COND","STD INSTALL","DIAPHRAGM","LP",6,"It is critical that the module inlet dimensions and orientation are given to the UIP when service works are taken place."
|
||||
"TERM_COND","STD INSTALL","DIAPHRAGM","LP",7,"The proposed meter module has a Qmin of nnn kWh and is based on the requested Qmax of nnn kWh.
|
||||
"
|
||||
"TERM_COND","STD INSTALL","DIAPHRAGM","MP",1,"Please note that all the sizes and dimensions stated are indicative and are based on current practice at the time of quotation. These are subject to change and must be confirmed at placement of order."
|
||||
"TERM_COND","STD INSTALL","DIAPHRAGM","MP",2,"Housings must have a free ventilation area equal to/exceeding 3% floor area. Minimum Housing requirements for this module are: L nnn mm x W nnn mm x H nnn mm . Failure to provide adequate housing will result in the job not being completed."
|
||||
"TERM_COND","STD INSTALL","DIAPHRAGM","MP",3,"Minimum Base dimension requirements for this module are: L nnn mm x W nnn mm x H nnn mm . Failure not to provide accurate base will result in the job not being completed."
|
||||
"TERM_COND","STD INSTALL","DIAPHRAGM","MP",4,"The Supply Point must be suitably sized and positioned to provide a minimum pressure of nnn (insert design minimum pressure) mbar under Qmax load at the ECV outlet point."
|
||||
"TERM_COND","STD INSTALL","DIAPHRAGM","MP",5,"This quotation is based on a xxxxxx (insert inlet orientation) inlet and xxxxxx (insert outlet orientation) outlet and the ECV being installed to the dimensions provided
|
||||
|
||||
The meter module offered is a xxxx (twin/single) stream supply with only a nominal bypass facility. The bypass is only used during maintenance, and is only sized to maintain gas pressure downstream. Please note that during maintenance it will be necessary to disrupt supplies."
|
||||
"TERM_COND","STD INSTALL","DIAPHRAGM","MP",6,"It is critical that the module inlet dimensions and orientation are given to the UIP when service works are taken place."
|
||||
"TERM_COND","STD INSTALL","DIAPHRAGM","MP",7,"The proposed meter module has a Qmin of nnn kWh and is based on the requested Qmax of nnn kWh."
|
||||
"TERM_COND","STD INSTALL","ROTARY","LP",1,"Please note that all the sizes and dimensions stated are indicative and are based on current practice at the time of quotation. These are subject to change and must be confirmed at placement of order."
|
||||
"TERM_COND","STD INSTALL","ROTARY","LP",2,"Housings must have a free ventilation area equal to/exceeding 3% floor area. Minimum Housing requirements for this module are: L nnn mm x W nnn mm x H nnn mm . Failure to provide adequate housing will result in the job not being completed."
|
||||
"TERM_COND","STD INSTALL","ROTARY","LP",3,"Minimum Base dimension requirements for this module are: L nnn mm x W nnn mm x H nnn mm . Failure not to provide accurate base will result in the job not being completed."
|
||||
"TERM_COND","STD INSTALL","ROTARY","LP",4,"The Supply Point must be suitably sized and positioned to provide a minimum pressure of 25 mbar under Qmax load at the ECV outlet point."
|
||||
"TERM_COND","STD INSTALL","ROTARY","LP",5,"This quotation is based on a xxxxxx (insert inlet orientation) inlet and xxxxxx (insert outlet orientation) outlet and the ECV being installed to the dimensions provided
|
||||
|
||||
The meter module is a single stream supply with no bypass facility. During maintenance operations on the meter installation it may be necessary to isolate the supply temporarily."
|
||||
"TERM_COND","STD INSTALL","ROTARY","LP",6,"It is critical that the module inlet dimensions and orientation are given to the UIP when service works are taken place."
|
||||
"TERM_COND","STD INSTALL","ROTARY","LP",7,"The proposed meter module has a Qmin of nnn kWh and is based on the requested Qmax of nnn kWh."
|
||||
"TERM_COND","STD INSTALL","ROTARY","MP",1,"Please note that all the sizes and dimensions stated are indicative and are based on current practice at the time of quotation. These are subject to change and must be confirmed at placement of order."
|
||||
"TERM_COND","STD INSTALL","ROTARY","MP",2,"Housings must have a free ventilation area equal to/exceeding 3% floor area. Minimum Housing requirements for this module are: L nnn mm x W nnn mm x H nnn mm . Failure to provide adequate housing will result in the job not being completed."
|
||||
"TERM_COND","STD INSTALL","ROTARY","MP",3,"Minimum Base dimension requirements for this module are: L nnn mm x W nnn mm x H nnn mm . Failure not to provide accurate base will result in the job not being completed."
|
||||
"TERM_COND","STD INSTALL","ROTARY","MP",4,"The Supply Point must be suitably sized and positioned to provide a minimum pressure of nnn (insert design minimum pressure) mbar under Qmax load at the ECV outlet point."
|
||||
"TERM_COND","STD INSTALL","ROTARY","MP",5,"This quotation is based on a xxxxxx (insert inlet orientation) inlet and xxxxxx (insert outlet orientation) outlet and the ECV being installed to the dimensions provided
|
||||
|
||||
The meter module offered is a xxxx (twin/single) stream supply with only a nominal bypass facility. The bypass is only used during maintenance, and is only sized to maintain gas pressure downstream. Please note that during maintenance it will be necessary to disrupt supplies."
|
||||
"TERM_COND","STD INSTALL","ROTARY","MP",6,"It is critical that the module inlet dimensions and orientation are given to the UIP when service works are taken place."
|
||||
"TERM_COND","STD INSTALL","ROTARY","MP",7,"The proposed meter module has a Qmin of nnn kWh and is based on the requested Qmax of nnn kWh."
|
||||
"TERM_COND","STD INSTALL","TURBINE","LP",1,"Please note that all the sizes and dimensions stated are indicative and are based on current practice at the time of quotation. These are subject to change and must be confirmed at placement of order."
|
||||
"TERM_COND","STD INSTALL","TURBINE","LP",2,"Housings must have a free ventilation area equal to/exceeding 3% floor area. Minimum Housing requirements for this module are: L nnn mm x W nnn mm x H nnn mm . Failure to provide adequate housing will result in the job not being completed."
|
||||
"TERM_COND","STD INSTALL","TURBINE","LP",3,"Minimum Base dimension requirements for this module are: L nnn mm x W nnn mm x H nnn mm . Failure not to provide accurate base will result in the job not being completed.
|
||||
"
|
||||
"TERM_COND","STD INSTALL","TURBINE","LP",4,"The Supply Point must be suitably sized and positioned to provide a minimum pressure of 25 mbar under Qmax load at the ECV outlet point."
|
||||
"TERM_COND","STD INSTALL","TURBINE","LP",5,"This quotation is based on a xxxxxx (insert inlet orientation) inlet and xxxxxx (insert outlet orientation) outlet and the ECV being installed to the dimensions provided
|
||||
|
||||
The meter module is a single stream supply with no bypass facility. During maintenance operations on the meter installation it may be necessary to isolate the supply temporarily."
|
||||
"TERM_COND","STD INSTALL","TURBINE","LP",6,"It is critical that the module inlet dimensions and orientation are given to the UIP when service works are taken place."
|
||||
"TERM_COND","STD INSTALL","TURBINE","LP",7,"The proposed meter module has a Qmin of nnn kWh and is based on the requested Qmax of nnn kWh."
|
||||
"TERM_COND","STD INSTALL","TURBINE","MP",1,"Please note that all the sizes and dimensions stated are indicative and are based on current practice at the time of quotation. These are subject to change and must be confirmed at placement of order."
|
||||
"TERM_COND","STD INSTALL","TURBINE","MP",2,"Housings must have a free ventilation area equal to/exceeding 3% floor area. Minimum Housing requirements for this module are: L nnn mm x W nnn mm x H nnn mm . Failure to provide adequate housing will result in the job not being completed."
|
||||
"TERM_COND","STD INSTALL","TURBINE","MP",3,"Minimum Base dimension requirements for this module are: L nnn mm x W nnn mm x H nnn mm . Failure not to provide accurate base will result in the job not being completed.
|
||||
"
|
||||
"TERM_COND","STD INSTALL","TURBINE","MP",4,"The Supply Point must be suitably sized and positioned to provide a minimum pressure of nnn (insert design minimum pressure) mbar under Qmax load at the ECV outlet point."
|
||||
"TERM_COND","STD INSTALL","TURBINE","MP",5,"This quotation is based on a xxxxxx (insert inlet orientation) inlet and xxxxxx (insert outlet orientation) outlet and the ECV being installed to the dimensions provided
|
||||
|
||||
The meter module offered is a xxxx (twin/single) stream supply with only a nominal bypass facility. The bypass is only used during maintenance, and is only sized to maintain gas pressure downstream. Please note that during maintenance it will be necessary to disrupt supplies.
|
||||
"
|
||||
"TERM_COND","STD INSTALL","TURBINE","MP",6,"It is critical that the module inlet dimensions and orientation are given to the UIP when service works are taken place."
|
||||
"TERM_COND","STD INSTALL","TURBINE","MP",7,"The proposed meter module has a Qmin of nnn kWh and is based on the requested Qmax of nnn kWh."
|
||||
"TERM_COND","STD REMOVE","DIAPHRAGM","LP",1,"This quotation is based on a low pressure service tier. If the pressure tier if found not to be low pressure, this will be subject to a new quotation or variation and planned meter works will not commence."
|
||||
"TERM_COND","STD REMOVE","DIAPHRAGM","LP",2,"Where purging of downstream supplies is necessary but has not been requested as part of the meter removal work, the meter will not be removed until the downstream supplies have been made safe by purging."
|
||||
|
295
Data/BulkLoad/COSTS.csv
Normal file
295
Data/BulkLoad/COSTS.csv
Normal file
@@ -0,0 +1,295 @@
|
||||
"REGI_CODE","SELLING_PRICE","COST_PRICE","DELIVERY_COST","VALID_FROM","VALID_TO","COST_TYPE","ENTY_CODE","MESC_CODE","SVCPT_CODE","METY_CODE","MODU_CODE","METR_CODE","HOU_CODE","BAS_CODE","ADIT_CODE"
|
||||
,43.1,,0,,,"MOCO",,,,,"AD016S",,,,
|
||||
,43.1,,0,,,"MOCO",,,,,"AD016SW",,,,
|
||||
,67.65,,0,,,"MOCO",,,,,"AD025S",,,,
|
||||
,67.65,,0,,,"MOCO",,,,,"AD025SW",,,,
|
||||
,86.32,,0,,,"MOCO",,,,,"AD040S",,,,
|
||||
,370.57,,0,,,"MOCO",,,,,"AD065S",,,,
|
||||
,419.27,,0,,,"MOCO",,,,,"AD100S",,,,
|
||||
,501.35,,0,,,"MOCO",,,,,"AD160S",,,,
|
||||
,207.94,,25,,,"MOCO",,,,,"ARCMVV0025A",,,,
|
||||
,207.94,,25,,,"MOCO",,,,,"ARCMVV0025AW",,,,
|
||||
,275.43,,25,,,"MOCO",,,,,"ARCMVV0040AW",,,,
|
||||
,275.43,,25,,,"MOCO",,,,,"ARCMVV0040A",,,,
|
||||
,629.9,,55,,,"MOCO",,,,,"ARCMHH0065A",,,,
|
||||
,629.9,,55,,,"MOCO",,,,,"ARCMVV0065A",,,,
|
||||
,629.9,,55,,,"MOCO",,,,,"ARCMVH0065A",,,,
|
||||
,629.9,,55,,,"MOCO",,,,,"ARCMHV0065A",,,,
|
||||
,629.9,,55,,,"MOCO",,,,,"ARCMHH0100A",,,,
|
||||
,629.9,,55,,,"MOCO",,,,,"ARCMVV0100A",,,,
|
||||
,629.9,,55,,,"MOCO",,,,,"ARCMVH0100A",,,,
|
||||
,629.9,,55,,,"MOCO",,,,,"ARCMHV0100A",,,,
|
||||
,868.74,,55,,,"MOCO",,,,,"ARCMVV0160A",,,,
|
||||
,868.74,,55,,,"MOCO",,,,,"ARCMHH0160A",,,,
|
||||
,868.74,,55,,,"MOCO",,,,,"ARCMVH0160A",,,,
|
||||
,868.74,,55,,,"MOCO",,,,,"ARCMHV0160A",,,,
|
||||
,868.74,,55,,,"MOCO",,,,,"ARCMVV0200A",,,,
|
||||
,868.74,,55,,,"MOCO",,,,,"ARCMHH0200A",,,,
|
||||
,868.74,,55,,,"MOCO",,,,,"ARCMVH0200A",,,,
|
||||
,868.74,,55,,,"MOCO",,,,,"ARCMHV0200A",,,,
|
||||
,868.74,,55,,,"MOCO",,,,,"ARCMVV0250A",,,,
|
||||
,868.74,,55,,,"MOCO",,,,,"ARCMHH0250A",,,,
|
||||
,868.74,,55,,,"MOCO",,,,,"ARCMVH0250A",,,,
|
||||
,868.74,,55,,,"MOCO",,,,,"ARCMHV0250A",,,,
|
||||
,1707.52,,55,,,"MOCO",,,,,"ARVV0250AP",,,,
|
||||
,1707.52,,55,,,"MOCO",,,,,"ARHH0250AP",,,,
|
||||
,1707.52,,55,,,"MOCO",,,,,"ARVH0250AP",,,,
|
||||
,1707.52,,55,,,"MOCO",,,,,"ARHV0250AP",,,,
|
||||
,1120.79,,55,,,"MOCO",,,,,"ARVV0300A",,,,
|
||||
,1120.79,,55,,,"MOCO",,,,,"ARHH0300A",,,,
|
||||
,1120.79,,55,,,"MOCO",,,,,"ARVH0300A",,,,
|
||||
,1120.79,,55,,,"MOCO",,,,,"ARHV0300A",,,,
|
||||
,2589.43,,90,,,"MOCO",,,,,"ARVV0300AP",,,,
|
||||
,2589.43,,90,,,"MOCO",,,,,"ARHH0300AP",,,,
|
||||
,2589.43,,90,,,"MOCO",,,,,"ARVH0300AP",,,,
|
||||
,2589.43,,90,,,"MOCO",,,,,"ARHV0300AP",,,,
|
||||
,1512.26,,55,,,"MOCO",,,,,"ARVV0400A",,,,
|
||||
,1512.26,,55,,,"MOCO",,,,,"ARHH0400A",,,,
|
||||
,1512.26,,55,,,"MOCO",,,,,"ARVH0400A",,,,
|
||||
,1512.26,,55,,,"MOCO",,,,,"ARHV0400A",,,,
|
||||
,1738.05,,90,,,"MOCO",,,,,"ARVV0650A",,,,
|
||||
,1738.05,,90,,,"MOCO",,,,,"ARHH0650A",,,,
|
||||
,1738.05,,90,,,"MOCO",,,,,"ARVH0650A",,,,
|
||||
,1738.05,,90,,,"MOCO",,,,,"ARHV0650A",,,,
|
||||
,3848.8,,500,,,"MOCO",,,,,"ARVV0650AP",,,,
|
||||
,3848.8,,500,,,"MOCO",,,,,"ARHH0650AP",,,,
|
||||
,3848.8,,500,,,"MOCO",,,,,"ARVH0650AP",,,,
|
||||
,3848.8,,500,,,"MOCO",,,,,"ARHV0650AP",,,,
|
||||
,1759.89,,90,,,"MOCO",,,,,"ARVV1000A",,,,
|
||||
,1759.89,,90,,,"MOCO",,,,,"ARHH1000A",,,,
|
||||
,1759.89,,90,,,"MOCO",,,,,"ARVH1000A",,,,
|
||||
,1759.89,,90,,,"MOCO",,,,,"ARHV1000A",,,,
|
||||
,4357.59,,500,,,"MOCO",,,,,"ARVV1000AP",,,,
|
||||
,4357.59,,500,,,"MOCO",,,,,"ARHH1000AP",,,,
|
||||
,4357.59,,500,,,"MOCO",,,,,"ARVH1000AP",,,,
|
||||
,4357.59,,500,,,"MOCO",,,,,"ARHV1000AP",,,,
|
||||
,323.14,,84,,,"MOCO",,,,,"ASD016A",,,,
|
||||
,376.64,,84,,,"MOCO",,,,,"ASD025A",,,,
|
||||
,531.62,,84,,,"MOCO",,,,,"ASD040A",,,,
|
||||
,1009.01,,84,,,"MOCO",,,,,"ASD065A",,,,
|
||||
,1437.89,,84,,,"MOCO",,,,,"ASD100A",,,,
|
||||
,1459.65,,84,,,"MOCO",,,,,"ASD160A",,,,
|
||||
,508.25,,84,,,"MOCO",,,,,"ASR0025A",,,,
|
||||
,519.16,,84,,,"MOCO",,,,,"ASR0040A",,,,
|
||||
,1455.88,,84,,,"MOCO",,,,,"ASR0100A",,,,
|
||||
,1631.75,,84,,,"MOCO",,,,,"ASR0160A",,,,
|
||||
,1872.86,,84,,,"MOCO",,,,,"ASR0200A",,,,
|
||||
,2722.36,,84,,,"MOCO",,,,,"ASR0250A",,,,
|
||||
,2958.96,,84,,,"MOCO",,,,,"ASR0300A",,,,
|
||||
,3291.32,,84,,,"MOCO",,,,,"ASR0400A",,,,
|
||||
,3504.74,,500,,,"MOCO",,,,,"ASR0650A",,,,
|
||||
,4111.42,,500,,,"MOCO",,,,,"ASR1000A",,,,
|
||||
,938.47,,70,,,"MOCO",,,,,"ASR0025D",,,,
|
||||
,938.47,,70,,,"MOCO",,,,,"ASR0040D",,,,
|
||||
,938.47,,70,,,"MOCO",,,,,"ASR0065D",,,,
|
||||
,2383.9,,70,,,"MOCO",,,,,"ASR0100D",,,,
|
||||
,2498.4,,70,,,"MOCO",,,,,"ASR0160D",,,,
|
||||
,2800,,90,,,"MOCO",,,,,"ASR0250D",,,,
|
||||
,2949.7,,90,,,"MOCO",,,,,"ASR0310D",,,,
|
||||
,3170.8,,150,,,"MOCO",,,,,"ASR0450D",,,,
|
||||
,3170.8,,150,,,"MOCO",,,,,"ASR0450DP",,,,
|
||||
,4753.7,,190,,,"MOCO",,,,,"ASR0650D",,,,
|
||||
,6263.9,,190,,,"MOCO",,,,,"ASR1075D",,,,
|
||||
,7463.9,,250,,,"MOCO",,,,,"ASR1600D",,,,
|
||||
,11450.4,,450,,,"MOCO",,,,,"ASR2885D",,,,
|
||||
,,,0,,,"MOCO",,,,,"Meter Only (Notes)",,,,
|
||||
,323.14,,84,,,"MOCO",,,,,"ASD016AW",,,,
|
||||
,441.57,,,,,"MECO",,,,,,"MRA25A",,,
|
||||
,490.19,,,,,"MECO",,,,,,"MRA40A",,,
|
||||
,635.51,,,,,"MECO",,,,,,"MRA65B",,,
|
||||
,635.51,,,,,"MECO",,,,,,"MRA100B",,,
|
||||
,786.11,,,,,"MECO",,,,,,"MRA160C",,,
|
||||
,1062.35,,,,,"MECO",,,,,,"MRA200C",,,
|
||||
,1117.65,,,,,"MECO",,,,,,"MRA250C",,,
|
||||
,1177.37,,,,,"MECO",,,,,,"MRA300D",,,
|
||||
,1258.72,,,,,"MECO",,,,,,"MRA400D",,,
|
||||
,3216.29,,,,,"MECO",,,,,,"MRA650E",,,
|
||||
,3788.23,,,,,"MECO",,,,,,"MRA1000E",,,
|
||||
,0,,0,,,"MECO",,,,,,"MRD0025B4B",,,
|
||||
,0,,0,,,"MECO",,,,,,"MRD0040B4B",,,
|
||||
,0,,0,,,"MECO",,,,,,"MRD0065B4B",,,
|
||||
,0,,0,,,"MECO",,,,,,"MRD0100B4B",,,
|
||||
,0,,0,,,"MECO",,,,,,"MRD0160B4C",,,
|
||||
,0,,0,,,"MECO",,,,,,"MRD0250B4D",,,
|
||||
,0,,0,,,"MECO",,,,,,"MRD0310B4D",,,
|
||||
,0,,0,,,"MECO",,,,,,"MRD0450B4D",,,
|
||||
,0,,0,,,"MECO",,,,,,"MRD0650B4E",,,
|
||||
,0,,0,,,"MECO",,,,,,"MRD1075B4E",,,
|
||||
,0,,0,,,"MECO",,,,,,"MRD2885A",,,
|
||||
,0,,0,,,"MECO",,,,,,"MDA16",,,
|
||||
,0,,0,,,"MECO",,,,,,"MDA25",,,
|
||||
,0,,0,,,"MECO",,,,,,"MDA40",,,
|
||||
,0,,0,,,"MECO",,,,,,"MDA65",,,
|
||||
,0,,0,,,"MECO",,,,,,"MDA100",,,
|
||||
,0,,0,,,"MECO",,,,,,"MDA160",,,
|
||||
,0,,0,,,"MECO",,,,,,"MRD1600B4F",,,
|
||||
,0,,0,,,"MECO",,,,,,"MRA1000SE",,,
|
||||
,0,,0,,,"MECO",,,,,,"MRA1000+",,,
|
||||
,0,,0,,,"MECO",,,,,,"MRA650SE",,,
|
||||
,0,,0,,,"MECO",,,,,,"MRD2885A10",,,
|
||||
,199.5,185,14.5,,,"HOCO",,,,,,,"GC2",,
|
||||
,244.5,220,15.5,,,"HOCO",,,,,,,"GC2FS",,
|
||||
,251.75,235,14.5,,,"HOCO",,,,,,,"GC2MP",,
|
||||
,301.36,270,14.5,,,"HOCO",,,,,,,"GC3",,
|
||||
,316.5,295,21.5,,,"HOCO",,,,,,,"GC4",,
|
||||
,532,495,37,,,"HOCO",,,,,,,"GC4+",,
|
||||
,627,585,42,,,"HOCO",,,,,,,"GC5",,
|
||||
,713.46,665,58,,,"HOCO",,,,,,,"GC6",,
|
||||
,903,830,73,,,"HOCO",,,,,,,"GC7",,
|
||||
,1040.5,965,75.5,,,"HOCO",,,,,,,"GC7+",,
|
||||
,2185,1990,195,,,"HOCO",,,,,,,"GC8",,
|
||||
,244.5,254,0,,,"HOCO",,,,,,,"Gas Cab No 2 (Multi)",,
|
||||
,301.36,299,0,,,"HOCO",,,,,,,"Gas Cab No 4",,
|
||||
,713.46,699,0,,,"HOCO",,,,,,,"Gas Cab No 6",,
|
||||
,0,2760,0,,,"HOCO",,,,,,,"Custom1",,
|
||||
,0,3071,0,,,"HOCO",,,,,,,"Custom2",,
|
||||
,0,3191,0,,,"HOCO",,,,,,,"Custom3",,
|
||||
,0,2959,0,,,"HOCO",,,,,,,"Custom4",,
|
||||
,0,3268,0,,,"HOCO",,,,,,,"Custom5",,
|
||||
,0,3850,0,,,"HOCO",,,,,,,"Custom6",,
|
||||
,0,0,0,,,"HOCO",,,,,,,"CustomK",,
|
||||
,2519,2519,0,,,"HOCO",,,,,,,"KP1",,
|
||||
,2725,2725,0,,,"HOCO",,,,,,,"KP2",,
|
||||
,2879,2879,0,,,"HOCO",,,,,,,"KP3",,
|
||||
,3416,3416,0,,,"HOCO",,,,,,,"KP4",,
|
||||
,3503,3503,0,,,"HOCO",,,,,,,"KP5",,
|
||||
,188.91,254,0,,,"HOCO",,,,,,,"Gas Cab No 2BB",,
|
||||
,301.36,299,0,,,"HOCO",,,,,,,"Gas Cab No 4BB25",,
|
||||
,310.99,299,0,,,"HOCO",,,,,,,"Gas Cab No 4BB40",,
|
||||
,713.46,699,0,,,"HOCO",,,,,,,"Gas Cab No 6BB",,
|
||||
,188.91,220,15.5,,,"HOCO",,,,,,,"GC2FSBB",,
|
||||
,301.36,270,14.5,,,"HOCO",,,,,,,"GC3BB",,
|
||||
,301.36,295,21.5,,,"HOCO",,,,,,,"GC4BB25",,
|
||||
,310.99,295,21.5,,,"HOCO",,,,,,,"GC4BB40",,
|
||||
,689.19,585,42,,,"HOCO",,,,,,,"GC5BB",,
|
||||
,713.46,665,58,,,"HOCO",,,,,,,"GC6BB",,
|
||||
,188.91,185,14.5,,,"HOCO",,,,,,,"GC2BB",,
|
||||
,251.75,254,0,,,"HOCO",,,,,,,"Gas Cab No 2MP",,
|
||||
,0,,,,,"BACO",,,,,,,,"0",
|
||||
,0,,,,,"BACO",,,,,,,,"CustomB",
|
||||
,625,,,,,"BACO",,,,,,,,"RA0025LPB",
|
||||
,625,,,,,"BACO",,,,,,,,"RA0025MPB",
|
||||
,625,,,,,"BACO",,,,,,,,"RA0040LPB",
|
||||
,625,,,,,"BACO",,,,,,,,"RA0040MPB",
|
||||
,1025,,,,,"BACO",,,,,,,,"RA0065LPB",
|
||||
,1025,,,,,"BACO",,,,,,,,"RA0100LPB",
|
||||
,625,,,,,"BACO",,,,,,,,"RA0100MPB",
|
||||
,1025,,,,,"BACO",,,,,,,,"RA0160LPB",
|
||||
,625,,,,,"BACO",,,,,,,,"RA0160MPB",
|
||||
,1025,,,,,"BACO",,,,,,,,"RA0200LPB",
|
||||
,625,,,,,"BACO",,,,,,,,"RA0200MPB",
|
||||
,1025,,,,,"BACO",,,,,,,,"RA0250+LPB",
|
||||
,1025,,,,,"BACO",,,,,,,,"RA0250LPB",
|
||||
,1025,,,,,"BACO",,,,,,,,"RA0250MPB",
|
||||
,1275,,,,,"BACO",,,,,,,,"RA0300+LPB",
|
||||
,1025,,,,,"BACO",,,,,,,,"RA0300LPB",
|
||||
,1025,,,,,"BACO",,,,,,,,"RA0300MPB",
|
||||
,1275,,,,,"BACO",,,,,,,,"RA0400LPB",
|
||||
,1025,,,,,"BACO",,,,,,,,"RA0400MPB",
|
||||
,1425,,,,,"BACO",,,,,,,,"RA0650+LPB",
|
||||
,1275,,,,,"BACO",,,,,,,,"RA0650LPB",
|
||||
,1275,,,,,"BACO",,,,,,,,"RA0650MPB",
|
||||
,1425,,,,,"BACO",,,,,,,,"RA1000+LPB",
|
||||
,1275,,,,,"BACO",,,,,,,,"RA1000LPB",
|
||||
,1275,,,,,"BACO",,,,,,,,"RA1000MPB",
|
||||
,625,,,,,"BACO",,,,,,,,"RD0025MPB",
|
||||
,625,,,,,"BACO",,,,,,,,"RD0040MPB",
|
||||
,625,,,,,"BACO",,,,,,,,"RD0065MPB",
|
||||
,625,,,,,"BACO",,,,,,,,"RD0100MPB",
|
||||
,0,,,,,"BACO",,,,,,,,"RD0160MPB",
|
||||
,1025,,,,,"BACO",,,,,,,,"RD0250MPB",
|
||||
,1025,,,,,"BACO",,,,,,,,"RD0310MPB",
|
||||
,1025,,,,,"BACO",,,,,,,,"RD0450+MPB",
|
||||
,1025,,,,,"BACO",,,,,,,,"RD0450MPB",
|
||||
,1275,,,,,"BACO",,,,,,,,"RD0650MPB",
|
||||
,1275,,,,,"BACO",,,,,,,,"RD1075MPB",
|
||||
,1275,,,,,"BACO",,,,,,,,"RD1600MPB",
|
||||
,0,,,,,"BACO",,,,,,,,"RD2885MPB",
|
||||
,625,,,,,"BACO",,,,,,,,"U016LPB",
|
||||
,625,,,,,"BACO",,,,,,,,"U016MPB",
|
||||
,625,,,,,"BACO",,,,,,,,"U025LPB",
|
||||
,625,,,,,"BACO",,,,,,,,"U025MPB",
|
||||
,625,,,,,"BACO",,,,,,,,"U040LPB",
|
||||
,625,,,,,"BACO",,,,,,,,"U040MPB",
|
||||
,625,,,,,"BACO",,,,,,,,"U065LPB",
|
||||
,1025,,,,,"BACO",,,,,,,,"U065MPB",
|
||||
,1025,,,,,"BACO",,,,,,,,"U100LPB",
|
||||
,1025,,,,,"BACO",,,,,,,,"U100MPB",
|
||||
,1025,,,,,"BACO",,,,,,,,"U160LPB",
|
||||
,1025,,,,,"BACO",,,,,,,,"U160MPB",
|
||||
,999,,,,,"AICO",,,,,,,,,"AMR"
|
||||
,999,,,,,"AICO",,,,,,,,,"EMS"
|
||||
,220,,,,,"AICO",,,,,,,,,"LIFTING GEAR"
|
||||
,0,,,,,"AICO",,,,,,,,,"PURGING"
|
||||
,999.01,,,,,"LACO","ADDON",,"LP","DIAPHRAGM",,,,,
|
||||
,999.02,,,,,"LACO","ADVERSARIAL",,"LP","DIAPHRAGM",,,,,
|
||||
,999.03,,,,,"LACO","CHANGE CAPACITY",,"LP","DIAPHRAGM",,,,,
|
||||
,999.04,,,,,"LACO","EXCHANGE",,"LP","DIAPHRAGM",,,,,
|
||||
,999.05,,,,,"LACO","INSTALL",,"LP","DIAPHRAGM",,,,,
|
||||
,999.06,,,,,"LACO","OFMAT",,"LP","DIAPHRAGM",,,,,
|
||||
,999.07,,,,,"LACO","OTHER",,"LP","DIAPHRAGM",,,,,
|
||||
,999.08,,,,,"LACO","ALTERATION",,"LP","DIAPHRAGM",,,,,
|
||||
,999.09,,,,,"LACO","REMOVE",,"LP","DIAPHRAGM",,,,,
|
||||
,999.1,,,,,"LACO","STD EXCHANGE",,"LP","DIAPHRAGM",,,,,
|
||||
,999.11,,,,,"LACO","STD INSTALL",,"LP","DIAPHRAGM",,,,,
|
||||
,999.12,,,,,"LACO","STD REMOVE",,"LP","DIAPHRAGM",,,,,
|
||||
,999.01,,,,,"LACO","ADDON",,"MP","DIAPHRAGM",,,,,
|
||||
,999.02,,,,,"LACO","ADVERSARIAL",,"MP","DIAPHRAGM",,,,,
|
||||
,999.03,,,,,"LACO","CHANGE CAPACITY",,"MP","DIAPHRAGM",,,,,
|
||||
,999.04,,,,,"LACO","EXCHANGE",,"MP","DIAPHRAGM",,,,,
|
||||
,999.05,,,,,"LACO","INSTALL",,"MP","DIAPHRAGM",,,,,
|
||||
,999.06,,,,,"LACO","OFMAT",,"MP","DIAPHRAGM",,,,,
|
||||
,999.07,,,,,"LACO","OTHER",,"MP","DIAPHRAGM",,,,,
|
||||
,999.08,,,,,"LACO","ALTERATION",,"MP","DIAPHRAGM",,,,,
|
||||
,999.09,,,,,"LACO","REMOVE",,"MP","DIAPHRAGM",,,,,
|
||||
,999.1,,,,,"LACO","STD EXCHANGE",,"MP","DIAPHRAGM",,,,,
|
||||
,999.11,,,,,"LACO","STD INSTALL",,"MP","DIAPHRAGM",,,,,
|
||||
,999.12,,,,,"LACO","STD REMOVE",,"MP","DIAPHRAGM",,,,,
|
||||
,999.01,,,,,"LACO","ADDON",,"HP","DIAPHRAGM",,,,,
|
||||
,999.02,,,,,"LACO","ADVERSARIAL",,"HP","DIAPHRAGM",,,,,
|
||||
,999.03,,,,,"LACO","CHANGE CAPACITY",,"HP","DIAPHRAGM",,,,,
|
||||
,999.04,,,,,"LACO","EXCHANGE",,"HP","DIAPHRAGM",,,,,
|
||||
,999.05,,,,,"LACO","INSTALL",,"HP","DIAPHRAGM",,,,,
|
||||
,999.06,,,,,"LACO","OFMAT",,"HP","DIAPHRAGM",,,,,
|
||||
,999.07,,,,,"LACO","OTHER",,"HP","DIAPHRAGM",,,,,
|
||||
,999.08,,,,,"LACO","ALTERATION",,"HP","DIAPHRAGM",,,,,
|
||||
,999.09,,,,,"LACO","REMOVE",,"HP","DIAPHRAGM",,,,,
|
||||
,999.1,,,,,"LACO","STD EXCHANGE",,"HP","DIAPHRAGM",,,,,
|
||||
,999.11,,,,,"LACO","STD INSTALL",,"HP","DIAPHRAGM",,,,,
|
||||
,999.12,,,,,"LACO","STD REMOVE",,"HP","DIAPHRAGM",,,,,
|
||||
,999.01,,,,,"LACO","ADDON",,"LP","ROTARY",,,,,
|
||||
,999.02,,,,,"LACO","ADVERSARIAL",,"LP","ROTARY",,,,,
|
||||
,999.03,,,,,"LACO","CHANGE CAPACITY",,"LP","ROTARY",,,,,
|
||||
,999.04,,,,,"LACO","EXCHANGE",,"LP","ROTARY",,,,,
|
||||
,999.05,,,,,"LACO","INSTALL",,"LP","ROTARY",,,,,
|
||||
,999.06,,,,,"LACO","OFMAT",,"LP","ROTARY",,,,,
|
||||
,999.07,,,,,"LACO","OTHER",,"LP","ROTARY",,,,,
|
||||
,999.08,,,,,"LACO","ALTERATION",,"LP","ROTARY",,,,,
|
||||
,999.09,,,,,"LACO","REMOVE",,"LP","ROTARY",,,,,
|
||||
,999.1,,,,,"LACO","STD EXCHANGE",,"LP","ROTARY",,,,,
|
||||
,999.11,,,,,"LACO","STD INSTALL",,"LP","ROTARY",,,,,
|
||||
,999.12,,,,,"LACO","STD REMOVE",,"LP","ROTARY",,,,,
|
||||
,999.01,,,,,"LACO","ADDON",,"MP","ROTARY",,,,,
|
||||
,999.02,,,,,"LACO","ADVERSARIAL",,"MP","ROTARY",,,,,
|
||||
,999.03,,,,,"LACO","CHANGE CAPACITY",,"MP","ROTARY",,,,,
|
||||
,999.04,,,,,"LACO","EXCHANGE",,"MP","ROTARY",,,,,
|
||||
,999.05,,,,,"LACO","INSTALL",,"MP","ROTARY",,,,,
|
||||
,999.06,,,,,"LACO","OFMAT",,"MP","ROTARY",,,,,
|
||||
,999.07,,,,,"LACO","OTHER",,"MP","ROTARY",,,,,
|
||||
,999.08,,,,,"LACO","ALTERATION",,"MP","ROTARY",,,,,
|
||||
,999.09,,,,,"LACO","REMOVE",,"MP","ROTARY",,,,,
|
||||
,999.1,,,,,"LACO","STD EXCHANGE",,"MP","ROTARY",,,,,
|
||||
,999.11,,,,,"LACO","STD INSTALL",,"MP","ROTARY",,,,,
|
||||
,999.12,,,,,"LACO","STD REMOVE",,"MP","ROTARY",,,,,
|
||||
,999.01,,,,,"LACO","ADDON",,"HP","ROTARY",,,,,
|
||||
,999.02,,,,,"LACO","ADVERSARIAL",,"HP","ROTARY",,,,,
|
||||
,999.03,,,,,"LACO","CHANGE CAPACITY",,"HP","ROTARY",,,,,
|
||||
,999.04,,,,,"LACO","EXCHANGE",,"HP","ROTARY",,,,,
|
||||
,999.05,,,,,"LACO","INSTALL",,"HP","ROTARY",,,,,
|
||||
,999.06,,,,,"LACO","OFMAT",,"HP","ROTARY",,,,,
|
||||
,999.07,,,,,"LACO","OTHER",,"HP","ROTARY",,,,,
|
||||
,999.08,,,,,"LACO","ALTERATION",,"HP","ROTARY",,,,,
|
||||
,999.09,,,,,"LACO","REMOVE",,"HP","ROTARY",,,,,
|
||||
,999.1,,,,,"LACO","STD EXCHANGE",,"HP","ROTARY",,,,,
|
||||
,999.11,,,,,"LACO","STD INSTALL",,"HP","ROTARY",,,,,
|
||||
,999.12,,,,,"LACO","STD REMOVE",,"HP","ROTARY",,,,,
|
||||
|
39
Data/BulkLoad/HOUSINGS.csv
Normal file
39
Data/BulkLoad/HOUSINGS.csv
Normal file
@@ -0,0 +1,39 @@
|
||||
"CODE","MANU_REF","DRWG_CODE","HOTY_CODE","DESCRIPTION","DIM_W","DIM_H","DIM_L","WEIGHT"
|
||||
"GC2","Gas Care","LO","Lift Off",,400,650,650,16
|
||||
"GC2FS","Gas Care","LO","Lift Off",,425,830,730,17
|
||||
"GC2MP","Gas Care","LO","Lift Off",,360,850,700,19
|
||||
"GC3","Gas Care","LO","Lift Off",,360,850,900,22
|
||||
"GC4","Gas Care","LO","Lift Off",,540,960,1000,30
|
||||
"GC4+","Gas Care","LO","Lift Off",,750,1200,1200,48
|
||||
"GC5","Gas Care","LO","Lift Off",,750,1350,1475,60
|
||||
"GC6","Gas Care","LO","Lift Off",,850,1450,1600,74
|
||||
"GC7","Gas Care","LO","Lift Off",,850,1595,1600,86
|
||||
"GC7+","Gas Care","LO","Lift Off",,850,1750,1600,0
|
||||
"GC8","Gas Care","LO","Lift Off",,1200,1800,2400,225
|
||||
"Gas Cab No 2 (Multi)","Kingsley","LO","Lift Off",,425,835,730,12
|
||||
"Gas Cab No 4","Kingsley","LO","Lift Off",,540,960,1000,25
|
||||
"Gas Cab No 6","Kingsley","LO","Lift Off",,855,1456,1610,52
|
||||
"Custom1","Kingsley","WT","Walk Thru",,1750,2250,3000,561
|
||||
"Custom2","Kingsley","WT","Walk Thru",,2000,2500,3000,664
|
||||
"Custom3","Kingsley","WT","Walk Thru",,2000,2750,3000,710
|
||||
"Custom4","Kingsley","WT","Walk Thru",,1750,2250,3500,626
|
||||
"Custom5","Kingsley","WT","Walk Thru",,2000,2250,4000,731
|
||||
"Custom6","Kingsley","WT","Walk Thru",,2750,2250,4500,925
|
||||
"CustomK","Kingsley","WT","Walk Thru",,0,0,0,0
|
||||
"KP1","Kingsley","WT","Walk Thru",,1600,2250,2500,529
|
||||
"KP2","Kingsley","WT","Walk Thru",,1600,2250,3000,599
|
||||
"KP3","Kingsley","WT","Walk Thru",,1600,2250,3500,664
|
||||
"KP4","Kingsley","WT","Walk Thru",,2500,2250,3750,856
|
||||
"KP5","Kingsley","WT","Walk Thru",,2500,2250,4000,894
|
||||
"Gas Cab No 2BB","Kingsley","LO","Lift Off",,425,835,730,12
|
||||
"Gas Cab No 4BB25","Kingsley","LO","Lift Off",,540,960,1000,25
|
||||
"Gas Cab No 4BB40","Kingsley","LO","Lift Off",,540,960,1000,25
|
||||
"Gas Cab No 6BB","Kingsley","LO","Lift Off",,855,1456,1610,52
|
||||
"GC2FSBB","Gas Care","LO","Lift Off",,425,830,730,17
|
||||
"GC3BB","Gas Care","LO","Lift Off",,360,850,900,22
|
||||
"GC4BB25","Gas Care","LO","Lift Off",,540,960,1000,30
|
||||
"GC4BB40","Gas Care","LO","Lift Off",,540,960,1000,30
|
||||
"GC5BB","Gas Care","LO","Lift Off",,750,1350,1475,60
|
||||
"GC6BB","Gas Care","LO","Lift Off",,850,1450,1600,74
|
||||
"GC2BB","Gas Care","LO","Lift Off",,400,650,650,16
|
||||
"Gas Cab No 2MP","Kingsley","LO","Lift Off",,425,835,730,12
|
||||
|
@@ -1,30 +1,34 @@
|
||||
"CODE","DRWG_CODE","METY_CODE","PRTY_ID","DIM_A","DIM_B","CENTRES","DIM_C","WEIGHT","QMAX","VALID_FROM","VALID_TO","QNOM","QMIN"
|
||||
"MRA25A",,"ROTARY",100,121,96,0,159,2.7,25,13/02/2007,,25,1.3
|
||||
"MRA40A",,"ROTARY",100,121,96,0,189,3.4,40,13/02/2007,,40,2
|
||||
"MRA65B",,"ROTARY",100,171,96,0,307,3.4,65,13/02/2007,,65,2
|
||||
"MRA100B",,"ROTARY",100,171,182,0,307,11,100,13/02/2007,,92.53,5
|
||||
"MRA160C",,"ROTARY",100,171,182,0,382,15,160,13/02/2007,,160,8
|
||||
"MRA200C",,"ROTARY",100,171,182,0,428,17,200,13/02/2007,,187.79,10
|
||||
"MRA250C",,"ROTARY",100,241,235,0,409,29,250,13/02/2007,,201.91,12.5
|
||||
"MRA300D",,"ROTARY",100,241,235,0,479,34,300,13/02/2007,,264.69,15
|
||||
"MRA400D",,"ROTARY",100,241,235,0,615,43,400,13/02/2007,,329.15,20
|
||||
"MRA650E",,"ROTARY",100,450,308,0,665,104,650,13/02/2007,,534.87,32.5
|
||||
"MRA1000E",,"ROTARY",100,500,400,0,820,197,1000,13/02/2007,,666.4,50
|
||||
"MRD0025B4B",,"ROTARY",101,171,152,0,316,8,25,13/02/2007,,25,1.25
|
||||
"MRD0040B4B",,"ROTARY",101,171,152,0,353,10,40,13/02/2007,,40,2
|
||||
"MRD0065B4B",,"ROTARY",101,171,177,0,357,12,65,13/02/2007,,57,3.25
|
||||
"MRD0100B4B",,"ROTARY",101,171,177,0,388,14,100,13/02/2007,,81,5
|
||||
"MRD0160B4C",,"ROTARY",101,171,177,0,460,17,160,13/02/2007,,130,8
|
||||
"MRD0250B4D",,"ROTARY",101,241,226,0,485,28,250,13/02/2007,,230,12.5
|
||||
"MRD0310B4D",,"ROTARY",101,241,226,0,502,29,310,13/02/2007,,285,15.5
|
||||
"MRD0450B4D",,"ROTARY",101,241,226,0,620,38,450,13/02/2007,,362,22.5
|
||||
"MRD0650B4E",,"ROTARY",101,406,457,0,684,94,650,13/02/2007,,547,32.5
|
||||
"MRD1075B4E",,"ROTARY",101,533,457,0,822,116,1075,13/02/2007,,710,54
|
||||
"MRD2885B4F",,"ROTARY",101,711,754,0,1295,1055,2885,13/02/2007,,2137,144
|
||||
"MDA16",,"DIAPHRAGM",100,0,0,0,0,0,16,13/02/2007,,16,0.8
|
||||
"MDA25",,"DIAPHRAGM",100,0,0,0,0,0,25,13/02/2007,,25,1.25
|
||||
"MDA40",,"DIAPHRAGM",100,0,0,0,0,0,40,13/02/2007,,40,2
|
||||
"MDA65",,"DIAPHRAGM",100,0,0,0,0,0,65,13/02/2007,,65,3.25
|
||||
"MDA100",,"DIAPHRAGM",100,0,0,0,0,0,100,13/02/2007,,99,5
|
||||
"MDA160",,"DIAPHRAGM",100,0,0,0,0,0,160,13/02/2007,,136,8
|
||||
"MRD1600B4F",,"ROTARY",101,533,457,0,922,284,1600,13/02/2007,,1181,80
|
||||
"CODE","DRWG_CODE","METY_CODE","MANU_REF","DIM_A","DIM_B","CENTRES","DIM_C","WEIGHT","QMAX","VALID_FROM","VALID_TO","QNOM","QMIN"
|
||||
"MRA25A",,"ROTARY","ACTARIS",121,96,0,159,2.7,25,,,25,1.3
|
||||
"MRA40A",,"ROTARY","ACTARIS",121,96,0,189,3.4,40,,,40,2
|
||||
"MRA65B",,"ROTARY","ACTARIS",171,96,0,307,3.4,65,,,65,2
|
||||
"MRA100B",,"ROTARY","ACTARIS",171,182,0,307,11,100,,,92.53,5
|
||||
"MRA160C",,"ROTARY","ACTARIS",171,182,0,382,15,160,,,160,8
|
||||
"MRA200C",,"ROTARY","ACTARIS",171,182,0,428,17,200,,,187.79,10
|
||||
"MRA250C",,"ROTARY","ACTARIS",241,235,0,409,29,250,,,201.91,12.5
|
||||
"MRA300D",,"ROTARY","ACTARIS",241,235,0,479,34,300,,,264.69,15
|
||||
"MRA400D",,"ROTARY","ACTARIS",241,235,0,615,43,400,,,329.15,20
|
||||
"MRA650E",,"ROTARY","ACTARIS",450,308,0,665,104,650,,,534.87,32.5
|
||||
"MRA1000E",,"ROTARY","ACTARIS",500,400,0,820,197,1000,,,666.4,50
|
||||
"MRD0025B4B",,"ROTARY","DRESSER",171,152,0,316,8,25,,,25,1.25
|
||||
"MRD0040B4B",,"ROTARY","DRESSER",171,152,0,353,10,40,,,40,2
|
||||
"MRD0065B4B",,"ROTARY","DRESSER",171,177,0,357,12,65,,,57,3.25
|
||||
"MRD0100B4B",,"ROTARY","DRESSER",171,177,0,388,14,100,,,81,5
|
||||
"MRD0160B4C",,"ROTARY","DRESSER",171,177,0,460,17,160,,,130,8
|
||||
"MRD0250B4D",,"ROTARY","DRESSER",241,226,0,485,28,250,,,230,12.5
|
||||
"MRD0310B4D",,"ROTARY","DRESSER",241,226,0,502,29,310,,,285,15.5
|
||||
"MRD0450B4D",,"ROTARY","DRESSER",241,226,0,620,38,450,,,362,22.5
|
||||
"MRD0650B4E",,"ROTARY","DRESSER",406,457,0,684,94,650,,,547,32.5
|
||||
"MRD1075B4E",,"ROTARY","DRESSER",533,457,0,822,116,1075,,,710,54
|
||||
"MRD2885A",,"ROTARY","DRESSER",711,754,0,1295,1055,2885,,,2137,144
|
||||
"MDA16",,"DIAPHRAGM","ACTARIS",0,0,0,0,0,16,,,16,0.8
|
||||
"MDA25",,"DIAPHRAGM","ACTARIS",0,0,0,0,0,25,,,25,1.25
|
||||
"MDA40",,"DIAPHRAGM","ACTARIS",0,0,0,0,0,40,,,40,2
|
||||
"MDA65",,"DIAPHRAGM","ACTARIS",0,0,0,0,0,65,,,65,3.25
|
||||
"MDA100",,"DIAPHRAGM","ACTARIS",0,0,0,0,0,100,,,99,5
|
||||
"MDA160",,"DIAPHRAGM","ACTARIS",0,0,0,0,0,160,,,136,8
|
||||
"MRD1600B4F",,"ROTARY","DRESSER",533,457,0,922,284,1600,,,1181,80
|
||||
"MRA1000SE",,"ROTARY","ACTARIS",0,0,0,0,0,1000,,,517,50
|
||||
"MRA1000+",,"ROTARY","ACTARIS",0,0,0,0,0,1000,,,663,50
|
||||
"MRA650SE",,"ROTARY","ACTARIS",0,0,0,0,0,650,,,450,23.5
|
||||
"MRD2885A10",,"ROTARY","DRESSER",0,0,0,0,0,2885,,,2137,144
|
||||
|
||||
|
@@ -1,141 +1,96 @@
|
||||
"CODE","OUTLET_CNTY_CODE","INLET_CNTY_CODE","DRWG_CODE","METR_CODE","REVA_CODE","SLVA_CODE","SVCP_CODE","WEIGHT","INLET_HEIGHT","INLET_SIZE","OUTLET_PRESSURE","OUTLET_HEIGHT","OUTLET_SIZE","BAS_CODE","HOU_CODE","DIM_A","DIM_B","DIM_C","DIM_D","DIM_E","DIM_H","VALID_FROM","VALID_TO","REGU_CODE","FLTR_CODE","INLET_CNOR_CODE","OUTLET_CNOR_CODE","LEAD_TIME","MANU_REF"
|
||||
"ARILHH300A","(MM) PN16","(MM) PN16","lphhstd","MRA300D","BADDATA","BADDATA","LP",300,570,100,21,570,150,"3316HH1",3316,0,1677,287,300,331,1180,15/11/2007,,"J48-100","LOW LOSS STRAINER-100","HORIZONTAL LEFT","HORIZONTAL RIGHT",25,"ACTARIS"
|
||||
"ARILHH400A","(MM) PN16","(MM) PN16","lphhstd","MRA400D","BADDATA","BADDATA","LP",400,700,150,21,700,150,"3516HH1",3516,0,2001,287,350,350,1400,15/11/2007,,"J48-150","LOW LOSS STRAINER-150","HORIZONTAL LEFT","HORIZONTAL RIGHT",25,"ACTARIS"
|
||||
"ARILHH650A","(MM) PN16","(MM) PN16","lphhstd","MRA650E","BADDATA","BADDATA","LP",470,700,150,21,700,150,"3816HH1",3816,0,2199,287,350,376,1400,15/11/2007,,"DONKIN 226-150","LOW LOSS STRAINER-150","HORIZONTAL LEFT","HORIZONTAL RIGHT",25,"ACTARIS"
|
||||
"ARILHH1000A","(MM) PN16","(MM) PN16","lphhstd","MRA1000E","BADDATA","BADDATA","LP",620,700,150,21,700,150,"3816HH1",3816,0,2249,287,350,475,1513,15/11/2007,,"DONKIN 226-150","LOW LOSS STRAINER-150","HORIZONTAL LEFT","HORIZONTAL RIGHT",25,"ACTARIS"
|
||||
"ARCMHH100A","(MM) PN16","(MM) PN16","lphhcompac","MRA100B","BADDATA","BADDATA","LP",125,985,80,21,250,80,"A4EHH1","A4E",0,755,235,325,325,1350,15/11/2007,,"J90 ANGLED-80","LOW LOSS STRAINER-80","HORIZONTAL LEFT","HORIZONTAL RIGHT",25,"ACTARIS"
|
||||
"ARCMHH160A","(MM) PN16","(MM) PN16","lphhcompac","MRA160C","BADDATA","BADDATA","LP",140,945,80,21,250,100,"A4EHH1","A4E",0,800,225,325,325,1315,15/11/2007,,"J90 ANGLED-80","LOW LOSS STRAINER-80","HORIZONTAL LEFT","HORIZONTAL RIGHT",25,"ACTARIS"
|
||||
"ARCMHH200A","(MM) PN16","(MM) PN16","lphhcompac","MRA200C","BADDATA","BADDATA","LP",140,945,80,21,250,100,"A4EHH1","A4E",0,800,225,325,325,1315,15/11/2007,,"J90 ANGLED-80","LOW LOSS STRAINER-80","HORIZONTAL LEFT","HORIZONTAL RIGHT",25,"ACTARIS"
|
||||
"ARCMHH250A","(MM) PN16","(MM) PN16","lphhcompac","MRA250C","BADDATA","BADDATA","LP",140,1015,80,21,250,100,"A4EHH1","A4E",0,785,240,325,325,1388,15/11/2007,,"J90 ANGLED-80","LOW LOSS STRAINER-80","HORIZONTAL LEFT","HORIZONTAL RIGHT",25,"ACTARIS"
|
||||
"ARCMHH300A","(MM) PN16","(MM) PN16","lphhcompac","MRA300D","BADDATA","BADDATA","LP",175,1150,100,21,250,100,"A4EHH1","A4E",0,1000,230,327,328,1523,15/11/2007,,"J90 ANGLED-80","LOW LOSS STRAINER-100","HORIZONTAL LEFT","HORIZONTAL RIGHT",25,"ACTARIS"
|
||||
"ARCMVV25A","(MM) BSPT","(MM) BSPT","lpvvcom25","MRA25A","BADDATA","BADDATA","LP",25,105,40,21,0,40,"A1C","A1",37,310,48,80,125,410,15/11/2007,,"DONKIN 226-40","FIXED IN UNION-40","VERTICAL DOWN","VERTICAL DOWN",25,"ACTARIS"
|
||||
"ARCMVV40A","(MM) BSPT","(MM) BSPT","lpvvcom40","MRA40A","BADDATA","BADDATA","LP",40,238,50,21,0,40,"A1H","A1",46,356,48,128,127,545,15/11/2007,,"DONKIN 226-50","FIXED IN UNION-40","VERTICAL DOWN","VERTICAL DOWN",25,"ACTARIS"
|
||||
"ARCMVV100A","(MM) PN16","(MM) PN16","lpvvcompac","MRA100B","BADDATA","BADDATA","LP",105,350,80,21,100,80,"A4EC1","A4E",100,485,350,245,245,1411,15/11/2007,,"J90 ANGLED-80","LOW LOSS STRAINER-80","VERTICAL DOWN","VERTICAL DOWN",25,"ACTARIS"
|
||||
"ARCMVV160A","(MM) PN16","(MM) PN16","lpvvcompac","MRA160C","BADDATA","BADDATA","LP",115,350,80,21,100,100,"A4EC1","A4E",100,485,350,245,245,1411,15/11/2007,,"J90 ANGLED-80","LOW LOSS STRAINER-80","VERTICAL DOWN","VERTICAL DOWN",25,"ACTARIS"
|
||||
"ARCMVV200A","(MM) PN16","(MM) PN16","lpvvcompac","MRA200C","BADDATA","BADDATA","LP",115,350,80,21,100,100,"A4EC1","A4E",100,485,350,245,245,1411,15/11/2007,,"J90 ANGLED-80","LOW LOSS STRAINER-80","VERTICAL DOWN","VERTICAL DOWN",25,"ACTARIS"
|
||||
"ARCMVV250A","(MM) PN16","(MM) PN16","lpvvcompac","MRA250C","BADDATA","BADDATA","LP",125,350,80,21,50,100,"A4EC1","A4E",100,485,350,245,245,1382,15/11/2007,,"J90 ANGLED-80","LOW LOSS STRAINER-80","VERTICAL DOWN","VERTICAL DOWN",25,"ACTARIS"
|
||||
"ARCMVV300A","(MM) PN16","(MM) PN16","lpvvcompac","MRA300D","BADDATA","BADDATA","LP",145,400,100,21,100,100,"A4EC2","A4E",115,635,300,245,245,1342,15/11/2007,,"J90 ANGLED-100","LOW LOSS STRAINER-100","VERTICAL DOWN","VERTICAL DOWN",25,"ACTARIS"
|
||||
"ARCMVH100A","(MM) PN16","(MM) PN16","lpvhcompac","MRA100B","BADDATA","BADDATA","LP",95,350,80,21,250,80,"A4EVH1","A4E",100,845,225,245,245,1315,15/11/2007,,"J90 ANGLED-80","LOW LOSS STRAINER-80","VERTICAL DOWN","HORIZONTAL RIGHT",25,"ACTARIS"
|
||||
"ARCMVH160A","(MM) PN16","(MM) PN16","lpvhcompac","MRA160C","BADDATA","BADDATA","LP",140,350,80,21,250,100,"A4EVH1","A4E",100,885,225,245,245,1315,15/11/2007,,"J90 ANGLED-80","LOW LOSS STRAINER-80","VERTICAL DOWN","HORIZONTAL RIGHT",25,"ACTARIS"
|
||||
"ARCMVH200A","(MM) PN16","(MM) PN16","lpvhcompac","MRA200C","BADDATA","BADDATA","LP",140,350,80,21,250,100,"A4EVH1","A4E",100,885,225,325,325,1315,15/11/2007,,"J90 ANGLED-80","LOW LOSS STRAINER-80","VERTICAL DOWN","HORIZONTAL RIGHT",25,"ACTARIS"
|
||||
"ARCMVH250A","(MM) PN16","(MM) PN16","lpvhcompac","MRA250C","BADDATA","BADDATA","LP",145,350,80,21,250,100,"A4EVH1","A4E",100,885,225,325,325,1315,15/11/2007,,"J90 ANGLED-80","LOW LOSS STRAINER-80","VERTICAL DOWN","HORIZONTAL RIGHT",25,"ACTARIS"
|
||||
"ARCMVH300A","(MM) PN16","(MM) PN16","lpvhcompac","MRA300D","BADDATA","BADDATA","LP",145,400,100,21,250,100,"A4EVH1","A4E",115,1160,225,322,322,1356,15/11/2007,,"J90 ANGLED-80","LOW LOSS STRAINER-100","VERTICAL DOWN","HORIZONTAL RIGHT",25,"ACTARIS"
|
||||
"ASD16VV35A","BADDATA","BADDATA","BADDATA","MDA16","BADDATA","BADDATA","MP35",45,0,0,21,0,0,,"A2",0,0,0,0,0,0,15/11/2007,,"BADDATA","BADDATA","VERTICAL DOWN","VERTICAL UP",25,"ACTARIS"
|
||||
"ASD25VV35A","BADDATA","BADDATA","BADDATA","MDA25","BADDATA","BADDATA","MP35",45,0,0,21,0,0,,"A2",0,0,0,0,0,0,15/11/2007,,"BADDATA","BADDATA","VERTICAL DOWN","VERTICAL UP",25,"ACTARIS"
|
||||
"ASD40VV35A","BADDATA","BADDATA","BADDATA","MDA40","BADDATA","BADDATA","MP35",130,0,0,21,0,0,,"A2",0,0,0,0,0,0,15/11/2007,,"BADDATA","BADDATA","VERTICAL DOWN","VERTICAL UP",25,"ACTARIS"
|
||||
"ASD65VV35A","BADDATA","BADDATA","BADDATA","MDA65","BADDATA","BADDATA","MP35",137,0,0,21,0,0,,"A3",0,0,0,0,0,0,15/11/2007,,"BADDATA","BADDATA","VERTICAL DOWN","VERTICAL UP",25,"ACTARIS"
|
||||
"ASD100VV35","BADDATA","BADDATA","BADDATA","MDA100","BADDATA","BADDATA","MP35",145,0,0,21,0,0,,"A4E",0,0,0,0,0,0,15/11/2007,,"BADDATA","BADDATA","VERTICAL DOWN","VERTICAL UP",25,"ACTARIS"
|
||||
"ASD160VV35A","BADDATA","BADDATA","BADDATA","MDA160","BADDATA","BADDATA","MP35",205,0,0,21,0,0,,"A4E",0,0,0,0,0,0,15/11/2007,,"BADDATA","BADDATA","VERTICAL DOWN","VERTICAL UP",25,"ACTARIS"
|
||||
"ASR25VV35A","(MM) PN16","(MM) PN16","BADDATA","MRA25A","BADDATA","BADDATA","MP35",70,0,0,21,0,0,"A2","A2",0,0,0,0,0,0,15/11/2007,,"BADDATA","BADDATA","VERTICAL DOWN","VERTICAL DOWN",25,"ACTARIS"
|
||||
"ARILHH100A","(MM) PN16","(MM) PN16","lphhstd","MRA100B","BADDATA","BADDATA","LP",100,540,80,21,540,80,"2016HH1",2016,0,1390,172,200,200,915,15/11/2007,,"J48-80","LOW LOSS STRAINER-80","HORIZONTAL LEFT","HORIZONTAL RIGHT",25,"ACTARIS"
|
||||
"ARILHH160A","(MM) PN16","(MM) PN16","lphhstd","MRA160C","BADDATA","BADDATA","LP",125,540,80,21,540,100,"2016HH1",2016,0,1376,204,250,250,915,15/11/2007,,"J48-80","LOW LOSS STRAINER-80","HORIZONTAL LEFT","HORIZONTAL RIGHT",25,"ACTARIS"
|
||||
"ASR40VV35A","(MM) PN16","(MM) PN16","BADDATA","MRA40A","BADDATA","BADDATA","MP35",75,0,0,21,0,0,"A2","A2",0,0,0,0,0,0,15/11/2007,,"BADDATA","BADDATA","VERTICAL DOWN","VERTICAL DOWN",25,"ACTARIS"
|
||||
"ARILHH200A","(MM) PN16","(MM) PN16","lphhstd","MRA200C","BADDATA","BADDATA","LP",125,540,80,21,540,100,"2516HH1",2516,0,1376,204,250,250,915,15/11/2007,,"J48-80","LOW LOSS STRAINER-80","HORIZONTAL LEFT","HORIZONTAL RIGHT",25,"ACTARIS"
|
||||
"ARILHH250A","(MM) PN16","(MM) PN16","lphhstd","MRA250C","BADDATA","BADDATA","LP",125,540,80,21,540,100,"2816HH1",2816,0,1446,204,250,250,915,15/11/2007,,"J48-80","LOW LOSS STRAINER-80","HORIZONTAL LEFT","HORIZONTAL RIGHT",25,"ACTARIS"
|
||||
"ASR200VV180A","(MM) PN16","(MM) PN16","BADDATA","MRA200C","BADDATA","BADDATA","MP180",100,0,0,21,0,0,,"A3",0,0,0,0,0,0,15/11/2007,,"BADDATA","BADDATA","VERTICAL DOWN","VERTICAL DOWN",25,"ACTARIS"
|
||||
"ASR250VV180A","(MM) PN16","(MM) PN16","BADDATA","MRA250C","BADDATA","BADDATA","MP180",160,0,0,21,0,0,,"A3",0,0,0,0,0,0,15/11/2007,,"BADDATA","BADDATA","VERTICAL DOWN","VERTICAL DOWN",25,"ACTARIS"
|
||||
"ASR300VV180A","(MM) PN16","(MM) PN16","BADDATA","MRA300D","BADDATA","BADDATA","MP180",350,0,0,21,0,0,,"A4E",0,0,0,0,0,0,15/11/2007,,"BADDATA","BADDATA","VERTICAL DOWN","VERTICAL DOWN",25,"ACTARIS"
|
||||
"ASR400VV180A","(MM) PN16","(MM) PN16","BADDATA","MRA400D","BADDATA","BADDATA","MP180",375,0,0,21,0,0,,"A4E",0,0,0,0,0,0,15/11/2007,,"BADDATA","BADDATA","VERTICAL DOWN","VERTICAL DOWN",25,"ACTARIS"
|
||||
"ASR650VV180A","(MM) PN16","(MM) PN16","BADDATA","MRA650E","BADDATA","BADDATA","MP180",500,0,0,21,0,0,,2516,0,0,0,0,0,0,15/11/2007,,"BADDATA","BADDATA","VERTICAL DOWN","VERTICAL DOWN",25,"ACTARIS"
|
||||
"ASR1000VV180A","(MM) PN16","(MM) PN16","BADDATA","MRA1000E","BADDATA","BADDATA","MP180",750,0,0,21,0,0,,3016,0,0,0,0,0,0,15/11/2007,,"BADDATA","BADDATA","VERTICAL DOWN","VERTICAL DOWN",25,"ACTARIS"
|
||||
"ASD16VV270A","BADDATA","BADDATA","BADDATA","MDA16","BADDATA","BADDATA","MP270",30,0,0,21,0,0,,"A2",0,0,0,0,0,0,15/11/2007,,"BADDATA","BADDATA","VERTICAL DOWN","VERTICAL UP",25,"ACTARIS"
|
||||
"ASD25VV270A","BADDATA","BADDATA","BADDATA","MDA25","BADDATA","BADDATA","MP270",40,0,0,21,0,0,,"A2",0,0,0,0,0,0,15/11/2007,,"BADDATA","BADDATA","VERTICAL DOWN","VERTICAL UP",25,"ACTARIS"
|
||||
"ASD40VV270A","BADDATA","BADDATA","BADDATA","MDA40","BADDATA","BADDATA","MP270",60,0,0,21,0,0,,"A2",0,0,0,0,0,0,15/11/2007,,"BADDATA","BADDATA","VERTICAL DOWN","VERTICAL UP",25,"ACTARIS"
|
||||
"ASD65VV270A","BADDATA","BADDATA","BADDATA","MDA65","BADDATA","BADDATA","MP270",98,0,0,21,0,0,,"A3",0,0,0,0,0,0,15/11/2007,,"BADDATA","BADDATA","VERTICAL DOWN","VERTICAL UP",25,"ACTARIS"
|
||||
"ASD100VV270A","BADDATA","BADDATA","BADDATA","MDA100","BADDATA","BADDATA","MP270",137,0,0,21,0,0,,"A4E",0,0,0,0,0,0,15/11/2007,,"BADDATA","BADDATA","VERTICAL DOWN","VERTICAL UP",25,"ACTARIS"
|
||||
"ASD160VV270A","BADDATA","BADDATA","BADDATA","MDA160","BADDATA","BADDATA","MP270",193,0,0,21,0,0,,"A4E",0,0,0,0,0,0,15/11/2007,,"BADDATA","BADDATA","VERTICAL DOWN","VERTICAL UP",25,"ACTARIS"
|
||||
"ASR25VV270A","(MM) PN16","(MM) PN16","BADDATA","MRA25A","BADDATA","BADDATA","MP270",50,0,0,21,0,0,,"A1",0,0,0,0,0,0,15/11/2007,,"BADDATA","BADDATA","VERTICAL DOWN","VERTICAL DOWN",25,"ACTARIS"
|
||||
"ASR40VV270A","(MM) PN16","(MM) PN16","BADDATA","MRA40A","BADDATA","BADDATA","MP270",55,0,0,21,0,0,,"A1",0,0,0,0,0,0,15/11/2007,,"BADDATA","BADDATA","VERTICAL DOWN","VERTICAL DOWN",25,"ACTARIS"
|
||||
"ASR100VV270A","(MM) PN16","(MM) PN16","BADDATA","MRA100B","BADDATA","BADDATA","MP270",70,0,0,21,0,0,,"A2",0,0,0,0,0,0,15/11/2007,,"BADDATA","BADDATA","VERTICAL DOWN","VERTICAL DOWN",25,"ACTARIS"
|
||||
"ASR160VV270A","(MM) PN16","(MM) PN16","BADDATA","MRA160C","BADDATA","BADDATA","MP270",100,0,0,21,0,0,,"A3",0,0,0,0,0,0,15/11/2007,,"BADDATA","BADDATA","VERTICAL DOWN","VERTICAL DOWN",25,"ACTARIS"
|
||||
"ASR200VV270A","(MM) PN16","(MM) PN16","BADDATA","MRA200C","BADDATA","BADDATA","MP270",100,0,0,21,0,0,,"A3",0,0,0,0,0,0,15/11/2007,,"BADDATA","BADDATA","VERTICAL DOWN","VERTICAL DOWN",25,"ACTARIS"
|
||||
"ASR250VV270A","(MM) PN16","(MM) PN16","BADDATA","MRA250C","BADDATA","BADDATA","MP270",160,0,0,21,0,0,,"A3",0,0,0,0,0,0,15/11/2007,,"BADDATA","BADDATA","VERTICAL DOWN","VERTICAL DOWN",25,"ACTARIS"
|
||||
"ASR300VV270A","(MM) PN16","(MM) PN16","BADDATA","MRA300D","BADDATA","BADDATA","MP270",350,0,0,21,0,0,,"A4E",0,0,0,0,0,0,15/11/2007,,"BADDATA","BADDATA","VERTICAL DOWN","VERTICAL DOWN",25,"ACTARIS"
|
||||
"ASR400VV270A","(MM) PN16","(MM) PN16","BADDATA","MRA400D","BADDATA","BADDATA","MP270",375,0,0,21,0,0,,"A4E",0,0,0,0,0,0,15/11/2007,,"BADDATA","BADDATA","VERTICAL DOWN","VERTICAL DOWN",25,"ACTARIS"
|
||||
"ASR650VV270A","(MM) PN16","(MM) PN16","BADDATA","MRA650E","BADDATA","BADDATA","MP270",500,0,0,21,0,0,,2516,0,0,0,0,0,0,15/11/2007,,"BADDATA","BADDATA","VERTICAL DOWN","VERTICAL DOWN",25,"ACTARIS"
|
||||
"ASR1000VV270A","(MM) PN16","(MM) PN16","BADDATA","MRA1000E","BADDATA","BADDATA","MP270",750,0,0,21,0,0,,3016,0,0,0,0,0,0,15/11/2007,,"BADDATA","BADDATA","VERTICAL DOWN","VERTICAL DOWN",25,"ACTARIS"
|
||||
"ASR25D","(MM) BSPT","(MM) BSPT","mpvvstdrot","MRD0025B4B","INTEGRAL-15","INTEGRAL-40","MP270",17,74,40,21,65,50,"A2VV2","A2",186,500,76,119,197,955,15/11/2007,,"DONKIN FIG 270R-40","Y TYPE-40","VERTICAL DOWN","VERTICAL DOWN",25,"DRESSER"
|
||||
"ASR40D","(MM) BSPT","(MM) BSPT","mpvvstdrot","MRD0040B4B","INTEGRAL-15","INTEGRAL-40","MP270",19,74,40,21,65,50,"A2VV2","A2",186,500,76,137,216,955,15/11/2007,,"DONKIN FIG 270R-40","Y TYPE-40","VERTICAL DOWN","VERTICAL DOWN",25,"DRESSER"
|
||||
"ASR65D","(MM) BSPT","(MM) BSPT","mpvvstdrot","MRD0065B4B","INTEGRAL-15","INTEGRAL-40","MP270",21,74,40,21,65,50,"A2VV2","A2",186,500,78,200,230,925,15/11/2007,,"DONKIN FIG 270R-40","Y TYPE-40","VERTICAL DOWN","VERTICAL DOWN",25,"DRESSER"
|
||||
"ASR100D","(MM) PN16","(MM) PN16","mpvvstdrot","MRD0100B4B","INTEGRAL-15","INTEGRAL-50","MP270",82,150,50,21,150,50,"A3VV4","A3",200,640,80,200,420,1250,15/11/2007,,"DONKIN FIG 270R-50","Y TYPE-50","VERTICAL DOWN","VERTICAL DOWN",25,"DRESSER"
|
||||
"ASR160D","(MM) PN16","(MM) PN16","mpvvstdrot","MRD0160B4C","INTEGRAL-15","INTEGRAL-50","MP270",84,150,50,21,150,80,"A3VV4","A3",160,640,120,200,420,1250,15/11/2007,,"DONKIN FIG 270R-50","Y TYPE-50","VERTICAL DOWN","VERTICAL DOWN",25,"DRESSER"
|
||||
"ASR450D","(MM) PN16","(MM) PN16","mpvvlooprot","MRD0450B4D","10L-25","DONKIN FIG 305-50","MP270",246,365,100,21,300,100,"3215VV1",3215,166,400,1700,310,385,1400,15/11/2007,,"DONKIN FIG 280-50","ANGLE PATTERN-100","VERTICAL DOWN","VERTICAL DOWN",25,"DRESSER"
|
||||
"ASR650D","(MM) PN16","(MM) PN16","mpvvlooprot","MRD0650B4E","10L-25","DONKIN FIG 305-80","MP270",322,365,100,21,200,150,"3416VV1",3416,206,400,1830,350,350,1300,15/11/2007,,"DONKIN FIG 280-80","ANGLE PATTERN-100","VERTICAL DOWN","VERTICAL DOWN",25,"DRESSER"
|
||||
"ASR1075D","(MM) PN16","(MM) PN16","mpvvlooprot","MRD1075B4E","10L-25","DONKIN FIG 305-80","MP270",376,250,150,21,200,150,"3416VV2",3416,165,400,1815,381,442,1300,15/11/2007,,"DONKIN FIG 280-80","ANGLE PATTERN-150","VERTICAL DOWN","VERTICAL DOWN",25,"DRESSER"
|
||||
"ASR1600D","(MM) PN16","(MM) PN16","mpvvlooprot","MRD1600B4F","10L-25","DONKIN FIG 305-100","MP270",611,416,150,21,158,200,"3820VV1",3820,210,450,2150,428,527,1795,15/11/2007,,"DONKIN FIG 280-100","ANGLE PATTERN-150","VERTICAL DOWN","VERTICAL DOWN",25,"DRESSER"
|
||||
"AR25D","(MM) BSPT","(MM) BSPT","BADDATA","MRD0025B4B","BADDATA","BADDATA","LP",500,130,50,21,50,50,,,999,330,999,999,999,752,15/11/2007,,"BADDATA","BADDATA","VERTICAL DOWN","VERTICAL DOWN",25,"DRESSER"
|
||||
"AR40D","(MM) BSPT","(MM) BSPT","BADDATA","MRD0040B4B","BADDATA","BADDATA","LP",500,130,50,21,50,50,,,999,330,999,999,999,752,15/11/2007,,"BADDATA","BADDATA","VERTICAL DOWN","VERTICAL DOWN",25,"DRESSER"
|
||||
"AR50D","(MM) BSPT","(MM) BSPT","BADDATA","MRD0065B4B","BADDATA","BADDATA","LP",500,130,50,21,50,50,,,999,330,999,999,999,752,15/11/2007,,"BADDATA","BADDATA","VERTICAL DOWN","VERTICAL DOWN",25,"DRESSER"
|
||||
"AR81D","(MM) PN16","(MM) PN16","BADDATA","MRD0100B4B","BADDATA","BADDATA","LP",950,175,80,21,150,80,,,999,450,999,999,999,1400,15/11/2007,,"BADDATA","BADDATA","VERTICAL DOWN","VERTICAL DOWN",25,"DRESSER"
|
||||
"AR130D","(MM) PN16","(MM) PN16","BADDATA","MRD0160B4C","BADDATA","BADDATA","LP",950,175,80,21,150,80,,,999,450,999,999,999,1350,15/11/2007,,"BADDATA","BADDATA","VERTICAL DOWN","VERTICAL DOWN",25,"DRESSER"
|
||||
"AR229D","(MM) PN16","(MM) PN16","BADDATA","MRD0250B4D","BADDATA","BADDATA","LP",950,410,100,21,150,100,,,999,500,999,999,999,1420,15/11/2007,,"BADDATA","BADDATA","VERTICAL DOWN","VERTICAL DOWN",25,"DRESSER"
|
||||
"AR283D","(MM) PN16","(MM) PN16","BADDATA","MRD0310B4D","BADDATA","BADDATA","LP",1000,385,100,21,341,150,,,999,1991,999,999,999,1180,15/11/2007,,"BADDATA","BADDATA","VERTICAL DOWN","VERTICAL DOWN",25,"DRESSER"
|
||||
"AR362D","(MM) PN16","(MM) PN16","BADDATA","MRD0450B4D","BADDATA","BADDATA","LP",2630,435,150,21,341,150,,,999,1930,999,999,999,1515,15/11/2007,,"BADDATA","BADDATA","VERTICAL DOWN","VERTICAL DOWN",25,"DRESSER"
|
||||
"AR538D","(MM) PN16","(MM) PN16","BADDATA","MRD0650B4E","BADDATA","BADDATA","LP",2765,538,150,21,382,150,,,999,2025,999,999,999,1515,15/11/2007,,"BADDATA","BADDATA","VERTICAL DOWN","VERTICAL DOWN",25,"DRESSER"
|
||||
"AR708D","(MM) PN16","(MM) PN16","BADDATA","MRD1075B4E","BADDATA","BADDATA","LP",3070,547,150,21,461,150,,,999,2780,999,999,999,1510,15/11/2007,,"BADDATA","BADDATA","VERTICAL DOWN","VERTICAL DOWN",25,"DRESSER"
|
||||
"AR1076D","(MM) PN16","(MM) PN16","BADDATA","MRD1600B4F","BADDATA","BADDATA","LP",3615,520,150,21,300,150,,,999,3407,999,999,999,1490,15/11/2007,,"BADDATA","BADDATA","VERTICAL DOWN","VERTICAL DOWN",25,"DRESSER"
|
||||
"ASR25A","(MM) BSPT","(MM) BSPT","mpvvstdrot","MRA25A","INTEGRAL-15","INTEGRAL-25","MP270",50,110,20,21,86,40,"A1VV1","A1",25,399,47,86,103,575,15/11/2007,,"RBI 2111-25","Y TYPE-20","VERTICAL DOWN","VERTICAL DOWN",25,"ACTARIS"
|
||||
"ASR40A","(MM) BSPT","(MM) BSPT","mpvvstdrot","MRA40A","INTEGRAL-15","INTEGRAL-25","MP270",55,98,25,21,81,40,"A1VV2","A1",30,479,47,86,103,573,15/11/2007,,"RBI 2611-25","Y TYPE-20","VERTICAL DOWN","VERTICAL DOWN",25,"ACTARIS"
|
||||
"ASR100A","(MM) BSPT","(MM) BSPT","mpvvstdrot","MRA100B","VS811-25","INTEGRAL-25","MP270",70,80,40,21,125,50,"A2VV1","A2",180,680,90,128,272,1072,15/11/2007,,"RBE 4011-25","Y TYPE-40","VERTICAL DOWN","VERTICAL DOWN",25,"ACTARIS"
|
||||
"ASR160A","(MM) PN16","(MM) BSPT","mpvvstdrot","MRA160C","VS811-25","INTEGRAL-40","MP270",100,460,50,21,80,80,"A3VV1","A3",90,1280,101,200,250,1189,15/11/2007,,"RBE 1711-40","ANGLE PATTERN-50","VERTICAL DOWN","VERTICAL DOWN",25,"ACTARIS"
|
||||
"ASR200A","(MM) PN16","(MM) BSPT","mpvvstdrot","MRA200C","VS811-25","INTEGRAL-40","MP270",100,450,50,21,80,80,"A3VV2","A3",90,1223,100,210,286,1177,15/11/2007,,"RBE 1711-40","ANGLE PATTERN-50","VERTICAL DOWN","VERTICAL DOWN",25,"ACTARIS"
|
||||
"ASR250A","(MM) PN16","(MM) PN16","mpvvstdrot","MRA250C","VS811-25","INTEGRAL-40","MP270",160,355,80,21,80,80,"A3VV3","A3",113,1240,93,210,286,1270,15/11/2007,,"RBE 1711-40","ANGLE PATTERN-80","VERTICAL DOWN","VERTICAL DOWN",25,"ACTARIS"
|
||||
"ASR300A","(MM) PN16","(MM) PN16","mpvvstdrot","MRA300D","VS811-25","INTEGRAL-40","MP270",350,355,80,21,80,100,"A4EVV1","A4E",109,1310,111,240,335,1395,15/11/2007,,"RBE 4011-40","ANGLE PATTERN-80","VERTICAL DOWN","VERTICAL DOWN",25,"ACTARIS"
|
||||
"ASR400A","(MM) PN16","(MM) PN16","mpvvstdrot","MRA400D","VS811-25","INTEGRAL-40","MP270",375,355,80,21,80,100,"A4EVV2","A4E",104,1310,106,290,460,1400,15/11/2007,,"RBE 4011-40","ANGLE PATTERN-80","VERTICAL DOWN","VERTICAL DOWN",25,"ACTARIS"
|
||||
"ASR650A","(MM) PN16","(MM) PN16","mpvvstdrot","MRA650E","VS811-25","INTEGRAL-50","MP270",500,381,100,21,150,150,"2516VV1",2516,150,1467,250,300,465,1918,15/11/2007,,"RBE 4011-50","ANGLE PATTERN-100","VERTICAL DOWN","VERTICAL DOWN",25,"ACTARIS"
|
||||
"ASR1000A","(MM) PN16","(MM) PN16","mpvvstdrot","MRA1000E","VS811-25","INTEGRAL-80","MP270",750,419,150,21,150,150,"3016VV1",3016,157,1515,230,310,590,1967,15/11/2007,,"RBE 4011-80","ANGLE PATTERN-150","VERTICAL DOWN","VERTICAL DOWN",25,"ACTARIS"
|
||||
"ASD16A","(MM) BSPT","(MM) BSPT","mpvvstddia","MDA16","INTEGRAL-15","INTEGRAL-25","MP270",30,213,20,21,326,40,"A1HVO2","A1",25,363,95,170,180,682,15/11/2007,,"RBI 2011-25","Y TYPE-20","VERTICAL DOWN","VERTICAL UP",25,"ACTARIS"
|
||||
"ASD25A","(MM) BSPT","(MM) BSPT","mpvvstddia","MDA25","INTEGRAL-15","INTEGRAL-25","MP270",40,102,25,21,485,50,"A2HVO3","A2",140,529,76,143,165,691,15/11/2007,,"RBI 2111-25","Y TYPE-25","VERTICAL DOWN","VERTICAL UP",25,"ACTARIS"
|
||||
"ASD40A","(MM) BSPT","(MM) BSPT","mpvvstddia","MDA40","INTEGRAL-15","INTEGRAL-25","MP270",60,175,25,21,634,50,"A2HVO4","A2",60,678,137,178,203,914,15/11/2007,,"RBI 2611-25","Y TYPE-25","VERTICAL DOWN","VERTICAL UP",25,"ACTARIS"
|
||||
"ASD65A","(MM) PN16","(MM) BSPT","mpvvstddia","MDA65","INTEGRAL-15","INTEGRAL-40","MP270",98,151,40,21,797,80,"A3HVO4","A3",60,762,250,190,195,1006,15/11/2007,,"RBI 3211-40","Y TYPE-40","VERTICAL DOWN","VERTICAL UP",25,"ACTARIS"
|
||||
"ASD100A","(MM) PN16","(MM) BSPT","mpvvstddia","MDA100","VS811-25","INTEGRAL-25","MP270",137,134,40,21,937,80,"A3HVO5","A3",180,828,172,271,330,1319,15/11/2007,,"RBE 4011-25","Y TYPE-40","VERTICAL DOWN","VERTICAL UP",25,"ACTARIS"
|
||||
"ASR650VV35A","(MM) PN16","(MM) PN16","BADDATA","MRA650E","BADDATA","BADDATA","MP35",633,0,0,21,0,0,4516,4516,0,0,0,0,0,0,15/11/2007,,"BADDATA","BADDATA","VERTICAL DOWN","VERTICAL DOWN",25,"ACTARIS"
|
||||
"ASR1000VV35A","(MM) PN16","(MM) PN16","BADDATA","MRA1000E","BADDATA","BADDATA","MP35",883,0,0,21,0,0,4520,4520,0,0,0,0,0,0,15/11/2007,,"BADDATA","BADDATA","VERTICAL DOWN","VERTICAL DOWN",25,"ACTARIS"
|
||||
"ASD16VV65A","BADDATA","BADDATA","BADDATA","MDA16","BADDATA","BADDATA","MP65",35,0,0,21,0,0,,"A2",0,0,0,0,0,0,15/11/2007,,"BADDATA","BADDATA","VERTICAL DOWN","VERTICAL UP",25,"ACTARIS"
|
||||
"ASD25VV65A","BADDATA","BADDATA","BADDATA","MDA25","BADDATA","BADDATA","MP65",45,0,0,21,0,0,,"A2",0,0,0,0,0,0,15/11/2007,,"BADDATA","BADDATA","VERTICAL DOWN","VERTICAL UP",25,"ACTARIS"
|
||||
"ASD40VV65A","BADDATA","BADDATA","BADDATA","MDA40","BADDATA","BADDATA","MP65",130,0,0,21,0,0,,"A2",0,0,0,0,0,0,15/11/2007,,"BADDATA","BADDATA","VERTICAL DOWN","VERTICAL UP",25,"ACTARIS"
|
||||
"ASD65VV65A","BADDATA","BADDATA","BADDATA","MDA65","BADDATA","BADDATA","MP65",137,0,0,21,0,0,,"A3",0,0,0,0,0,0,15/11/2007,,"BADDATA","BADDATA","VERTICAL DOWN","VERTICAL UP",25,"ACTARIS"
|
||||
"ASD100VV65A","BADDATA","BADDATA","BADDATA","MDA100","BADDATA","BADDATA","MP65",145,0,0,21,0,0,,"A3",0,0,0,0,0,0,15/11/2007,,"BADDATA","BADDATA","VERTICAL DOWN","VERTICAL UP",25,"ACTARIS"
|
||||
"ASD160VV65A","BADDATA","BADDATA","BADDATA","MDA160","BADDATA","BADDATA","MP65",205,0,0,21,0,0,,"A3",0,0,0,0,0,0,15/11/2007,,"BADDATA","BADDATA","VERTICAL DOWN","VERTICAL UP",25,"ACTARIS"
|
||||
"ASR25VV65A","(MM) PN16","(MM) PN16","BADDATA","MRA25A","BADDATA","BADDATA","MP65",70,0,0,21,0,0,,"A2",0,0,0,0,0,0,15/11/2007,,"BADDATA","BADDATA","VERTICAL DOWN","VERTICAL DOWN",25,"ACTARIS"
|
||||
"ASR40VV65A","(MM) PN16","(MM) PN16","BADDATA","MRA40A","BADDATA","BADDATA","MP65",75,0,0,21,0,0,,"A2",0,0,0,0,0,0,15/11/2007,,"BADDATA","BADDATA","VERTICAL DOWN","VERTICAL DOWN",25,"ACTARIS"
|
||||
"ASR100VV65A","(MM) PN16","(MM) PN16","BADDATA","MRA100B","BADDATA","BADDATA","MP65",90,0,0,21,0,0,,"A3",0,0,0,0,0,0,15/11/2007,,"BADDATA","BADDATA","VERTICAL DOWN","VERTICAL DOWN",25,"ACTARIS"
|
||||
"ASR160VV65A","(MM) PN16","(MM) PN16","BADDATA","MRA160C","BADDATA","BADDATA","MP65",120,0,0,21,0,0,,"A4E",0,0,0,0,0,0,15/11/2007,,"BADDATA","BADDATA","VERTICAL DOWN","VERTICAL DOWN",25,"ACTARIS"
|
||||
"ASR200VV65A","(MM) PN16","(MM) PN16","BADDATA","MRA200C","BADDATA","BADDATA","MP65",120,0,0,21,0,0,,"A4E",0,0,0,0,0,0,15/11/2007,,"BADDATA","BADDATA","VERTICAL DOWN","VERTICAL DOWN",25,"ACTARIS"
|
||||
"ASR250VV65A","(MM) PN16","(MM) PN16","BADDATA","MRA250C","BADDATA","BADDATA","MP65",210,0,0,21,0,0,,2516,0,0,0,0,0,0,15/11/2007,,"BADDATA","BADDATA","VERTICAL DOWN","VERTICAL DOWN",25,"ACTARIS"
|
||||
"ASR300VV65A","(MM) PN16","(MM) PN16","BADDATA","MRA300D","BADDATA","BADDATA","MP65",380,0,0,21,0,0,,2516,0,0,0,0,0,0,15/11/2007,,"BADDATA","BADDATA","VERTICAL DOWN","VERTICAL DOWN",25,"ACTARIS"
|
||||
"ASR400VV65A","(MM) PN16","(MM) PN16","BADDATA","MRA400D","BADDATA","BADDATA","MP65",500,0,0,21,0,0,,3316,0,0,0,0,0,0,15/11/2007,,"BADDATA","BADDATA","VERTICAL DOWN","VERTICAL DOWN",25,"ACTARIS"
|
||||
"ASR650VV65A","(MM) PN16","(MM) PN16","BADDATA","MRA650E","BADDATA","BADDATA","MP65",625,0,0,21,0,0,,3516,0,0,0,0,0,0,15/11/2007,,"BADDATA","BADDATA","VERTICAL DOWN","VERTICAL DOWN",25,"ACTARIS"
|
||||
"ASR1000VV65A","(MM) PN16","(MM) PN16","BADDATA","MRA1000E","BADDATA","BADDATA","MP65",875,0,0,21,0,0,,3516,0,0,0,0,0,0,15/11/2007,,"BADDATA","BADDATA","VERTICAL DOWN","VERTICAL DOWN",25,"ACTARIS"
|
||||
"ASD16VV105A","BADDATA","BADDATA","BADDATA","MDA16","BADDATA","BADDATA","MP105",30,0,0,21,0,0,,"A2",0,0,0,0,0,0,15/11/2007,,"BADDATA","BADDATA","VERTICAL DOWN","VERTICAL UP",25,"ACTARIS"
|
||||
"ASD25VV105A","BADDATA","BADDATA","BADDATA","MDA25","BADDATA","BADDATA","MP105",40,0,0,21,0,0,,"A2",0,0,0,0,0,0,15/11/2007,,"BADDATA","BADDATA","VERTICAL DOWN","VERTICAL UP",25,"ACTARIS"
|
||||
"ASD40VV105A","BADDATA","BADDATA","BADDATA","MDA40","BADDATA","BADDATA","MP105",60,0,0,21,0,0,,"A2",0,0,0,0,0,0,15/11/2007,,"BADDATA","BADDATA","VERTICAL DOWN","VERTICAL UP",25,"ACTARIS"
|
||||
"ASD65VV105A","BADDATA","BADDATA","BADDATA","MDA65","BADDATA","BADDATA","MP105",98,0,0,21,0,0,,"A3",0,0,0,0,0,0,15/11/2007,,"BADDATA","BADDATA","VERTICAL DOWN","VERTICAL UP",25,"ACTARIS"
|
||||
"ASD100Vv105A","BADDATA","BADDATA","BADDATA","MDA100","BADDATA","BADDATA","MP105",137,0,0,21,0,0,,"A3",0,0,0,0,0,0,15/11/2007,,"BADDATA","BADDATA","VERTICAL DOWN","VERTICAL UP",25,"ACTARIS"
|
||||
"ASD160VV105A","BADDATA","BADDATA","BADDATA","MDA160","BADDATA","BADDATA","MP105",193,0,0,21,0,0,,"A3",0,0,0,0,0,0,15/11/2007,,"BADDATA","BADDATA","VERTICAL DOWN","VERTICAL UP",25,"ACTARIS"
|
||||
"ASR25VV105A","(MM) PN16","(MM) PN16","BADDATA","MRA25A","BADDATA","BADDATA","MP105",50,0,0,21,0,0,,"A1",0,0,0,0,0,0,15/11/2007,,"BADDATA","BADDATA","VERTICAL DOWN","VERTICAL DOWN",25,"ACTARIS"
|
||||
"ASR40VV105A","(MM) PN16","(MM) PN16","BADDATA","MRA40A","BADDATA","BADDATA","MP105",55,0,0,21,0,0,,"A1",0,0,0,0,0,0,15/11/2007,,"BADDATA","BADDATA","VERTICAL DOWN","VERTICAL DOWN",25,"ACTARIS"
|
||||
"ASR100VV105A","(MM) PN16","(MM) PN16","BADDATA","MRA100B","BADDATA","BADDATA","MP105",70,0,0,21,0,0,,"A2",0,0,0,0,0,0,15/11/2007,,"BADDATA","BADDATA","VERTICAL DOWN","VERTICAL DOWN",25,"ACTARIS"
|
||||
"ASR160VV105A","(MM) PN16","(MM) PN16","BADDATA","MRA160C","BADDATA","BADDATA","MP105",100,0,0,21,0,0,,"A3",0,0,0,0,0,0,15/11/2007,,"BADDATA","BADDATA","VERTICAL DOWN","VERTICAL DOWN",25,"ACTARIS"
|
||||
"ASR200VV105A","(MM) PN16","(MM) PN16","BADDATA","MRA200C","BADDATA","BADDATA","MP105",100,0,0,21,0,0,,"A3",0,0,0,0,0,0,15/11/2007,,"BADDATA","BADDATA","VERTICAL DOWN","VERTICAL DOWN",25,"ACTARIS"
|
||||
"ASR250VV105A","(MM) PN16","(MM) PN16","BADDATA","MRA250C","BADDATA","BADDATA","MP105",160,0,0,21,0,0,,"A3",0,0,0,0,0,0,15/11/2007,,"BADDATA","BADDATA","VERTICAL DOWN","VERTICAL DOWN",25,"ACTARIS"
|
||||
"ASR300VV105A","(MM) PN16","(MM) PN16","BADDATA","MRA300D","BADDATA","BADDATA","MP105",350,0,0,21,0,0,,"A4E",0,0,0,0,0,0,15/11/2007,,"BADDATA","BADDATA","VERTICAL DOWN","VERTICAL DOWN",25,"ACTARIS"
|
||||
"ASR400VV105A","(MM) PN16","(MM) PN16","BADDATA","MRA400D","BADDATA","BADDATA","MP105",375,0,0,21,0,0,,"A4E",0,0,0,0,0,0,15/11/2007,,"BADDATA","BADDATA","VERTICAL DOWN","VERTICAL DOWN",25,"ACTARIS"
|
||||
"ASR650VV105A","(MM) PN16","(MM) PN16","BADDATA","MRA650E","BADDATA","BADDATA","MP105",750,0,0,21,0,0,,3016,0,0,0,0,0,0,15/11/2007,,"BADDATA","BADDATA","VERTICAL DOWN","VERTICAL DOWN",25,"ACTARIS"
|
||||
"ASR1000VV105A","(MM) PN16","(MM) PN16","BADDATA","MRA1000E","BADDATA","BADDATA","MP105",750,0,0,21,0,0,,3516,0,0,0,0,0,0,15/11/2007,,"BADDATA","BADDATA","VERTICAL DOWN","VERTICAL DOWN",25,"ACTARIS"
|
||||
"ASD16VV180A","BADDATA","BADDATA","BADDATA","MDA16","BADDATA","BADDATA","MP180",30,0,0,21,0,0,,"A1",0,0,0,0,0,0,15/11/2007,,"BADDATA","BADDATA","VERTICAL DOWN","VERTICAL UP",25,"ACTARIS"
|
||||
"ASD25VV180A","BADDATA","BADDATA","BADDATA","MDA25","BADDATA","BADDATA","MP180",40,0,0,21,0,0,,"A2",0,0,0,0,0,0,15/11/2007,,"BADDATA","BADDATA","VERTICAL DOWN","VERTICAL UP",25,"ACTARIS"
|
||||
"ASD40VV180A","BADDATA","BADDATA","BADDATA","MDA40","BADDATA","BADDATA","MP180",60,0,0,21,0,0,,"A2",0,0,0,0,0,0,15/11/2007,,"BADDATA","BADDATA","VERTICAL DOWN","VERTICAL UP",25,"ACTARIS"
|
||||
"ASD65VV180A","BADDATA","BADDATA","BADDATA","MDA65","BADDATA","BADDATA","MP180",98,0,0,21,0,0,,"A3",0,0,0,0,0,0,15/11/2007,,"BADDATA","BADDATA","VERTICAL DOWN","VERTICAL UP",25,"ACTARIS"
|
||||
"ASD100Vv180A","BADDATA","BADDATA","BADDATA","MDA100","BADDATA","BADDATA","MP180",137,0,0,21,0,0,,"A3",0,0,0,0,0,0,15/11/2007,,"BADDATA","BADDATA","VERTICAL DOWN","VERTICAL UP",25,"ACTARIS"
|
||||
"ASD160VV180A","BADDATA","BADDATA","BADDATA","MDA160","BADDATA","BADDATA","MP180",193,0,0,21,0,0,,"A3",0,0,0,0,0,0,15/11/2007,,"BADDATA","BADDATA","VERTICAL DOWN","VERTICAL UP",25,"ACTARIS"
|
||||
"ASR25VV180A","(MM) PN16","(MM) PN16","BADDATA","MRA25A","BADDATA","BADDATA","MP180",50,0,0,21,0,0,,"A1",0,0,0,0,0,0,15/11/2007,,"BADDATA","BADDATA","VERTICAL DOWN","VERTICAL DOWN",25,"ACTARIS"
|
||||
"ASR40VV180A","(MM) PN16","(MM) PN16","BADDATA","MRA40A","BADDATA","BADDATA","MP180",55,0,0,21,0,0,,"A1",0,0,0,0,0,0,15/11/2007,,"BADDATA","BADDATA","VERTICAL DOWN","VERTICAL DOWN",25,"ACTARIS"
|
||||
"ASR100VV180A","(MM) PN16","(MM) PN16","BADDATA","MRA100B","BADDATA","BADDATA","MP180",70,0,0,21,0,0,,"A2",0,0,0,0,0,0,15/11/2007,,"BADDATA","BADDATA","VERTICAL DOWN","VERTICAL DOWN",25,"ACTARIS"
|
||||
"ASR160VV180A","(MM) PN16","(MM) PN16","BADDATA","MRA160C","BADDATA","BADDATA","MP180",100,0,0,21,0,0,,"A3",0,0,0,0,0,0,15/11/2007,,"BADDATA","BADDATA","VERTICAL DOWN","VERTICAL DOWN",25,"ACTARIS"
|
||||
"AR10265H","BADDATA","BADDATA","BADDATA","MRD1600B4F","BADDATA","BADDATA","LP",3615,520,150,21,300,150,"2016HH1","1765H",999,3407,999,999,999,1490,04/12/2007,03/12/08,"J48-100","BADDATA","VERTICAL DOWN","VERTICAL DOWN",25,"DRESSER"
|
||||
"ASD160A","(MM) PN16","(MM) BSPT","mpvvstddia","MDA160","VS811-25","INTEGRAL-40","MP270",193,122,50,21,904,100,"A3HVO6","A3",180,840,250,305,340,1329,15/11/2007,,"RBE 1711-40","Y TYPE-50","VERTICAL DOWN","VERTICAL UP",25,"ACTARIS"
|
||||
"ARILHH65A","(MM) PN16","(MM) PN16","lphhstd","MRA65B","BADDATA","BADDATA","LP",100,540,80,21,540,80,"2016HH1",2016,0,1390,172,200,200,915,15/11/2007,,"J48-80","LOW LOSS STRAINER-80","HORIZONTAL LEFT","HORIZONTAL RIGHT",25,"ACTARIS"
|
||||
"ARCMHH65A","(MM) PN16","(MM) PN16","lphhcompac","MRA65B","BADDATA","BADDATA","LP",125,985,80,21,250,80,"A4EHH1","A4E",0,755,235,325,325,1350,15/11/2007,,"J90 ANGLED-80","LOW LOSS STRAINER-80","HORIZONTAL LEFT","HORIZONTAL RIGHT",25,"ACTARIS"
|
||||
"ARCMVV65A","(MM) PN16","(MM) PN16","lpvvcompac","MRA65B","BADDATA","BADDATA","LP",105,350,80,21,100,80,"A4EC1","A4E",100,485,350,245,245,1411,15/11/2007,,"J90 ANGLED-80","LOW LOSS STRAINER-80","VERTICAL DOWN","VERTICAL DOWN",25,"ACTARIS"
|
||||
"ARCMVH65A","(MM) PN16","(MM) PN16","lpvhcompac","MRA65B","BADDATA","BADDATA","LP",95,350,80,21,250,80,"A4EVH1","A4E",100,845,225,245,245,1315,15/11/2007,,"J90 ANGLED-80","LOW LOSS STRAINER-80","VERTICAL DOWN","HORIZONTAL RIGHT",25,"ACTARIS"
|
||||
"AD016S","(mm) BSPT","(mm) BS 746","lpvvstddia","MDA16",,,"LP",0,265,25,15,356,40,"U016LPB","GC2FSBB",550,320,95,170,180,556,,,"Speryn G1000","Gause","Vertical Down","Vertical Up",,"Actaris"
|
||||
"AD016SW","(mm) BSPT","(mm) BS 746","lpvvstddia","MDA16",,,"LP",0,265,25,15,356,40,"0","Gas Cab No 2BB",550,320,95,170,180,556,,,"Speryn G1000","Gause","Vertical Down","Vertical Up",,"Actaris"
|
||||
"AD025S","(mm) BSPT","(mm) BS 746","lpvvstddia","MDA25",,,"LP",0,265,50,15,475,50,"U025LPB","GC4BB25",637,270,78,143,165,675,,,"Speryn G1000","Gause","Vertical Down","Vertical Up",,"Actaris"
|
||||
"AD025SW","(mm) BSPT","(mm) BS 746","lpvvstddia","MDA25",,,"LP",0,265,50,15,475,50,"0","GC3BB",637,270,78,143,165,675,,,"Speryn G1000","Gause","Vertical Down","Vertical Up",,"Actaris"
|
||||
"AD040S","(mm) BSPT","(mm) BS 746","lpvvstddia","MDA40",,,"LP",0,265,50,15,675,50,"U040LPB","GC4BB40",750,350,137,178,203,765,,,"Speryn G1000","Gause","Vertical Down","Vertical Up",,"Actaris"
|
||||
"AD065S","(mm) PN16","(mm) BS 746","lpvvstddia","MDA65",,,"LP",0,265,80,15,800,80,"U065LPB","GC5BB",835,400,145,190,195,1065,,,"Speryn G1000","Gause","Vertical Down","Vertical Up",,"Actaris"
|
||||
"AD100S","(mm) PN16","(mm) PN16","lpvvstddia","MDA100",,,"LP",0,500,80,15,873,80,"U100LPB","Gas Cab No 6BB",1061,510,172,271,172,1140,,,"Speryn G1000","Gause","Vertical Down","Vertical Up",,"Actaris"
|
||||
"AD160S","(mm) PN16","(mm) PN16","lpvvstddia","MDA160",,,"LP",0,500,100,15,939,100,"U160LPB","Gas Cab No 6BB",1115,530,172,305,250,1175,,,"Speryn G1000","Gause","Vertical Down","Vertical Up",,"Actaris"
|
||||
"ARCMVV0025A","(mm) BSPT","(mm) BSPT","lpcompact4","MRA25A","0","0","LP",125,200,40,15,95,40,"RA0025LPB","Gas Cab No 2 (Multi)",395,205,310,0,0,565,,,"Fig 226","Flat Strainer","Vertical Down","Vertical Down",,"Actaris"
|
||||
"ARCMVV0025AW","(mm) BSPT","(mm) BSPT","lpcompact4","MRA25A","0","0","LP",125,200,40,15,95,40,"0","GC2",395,205,310,0,0,500,,,"Fig 226","Flat Strainer","Vertical Down","Vertical Down",,"Actaris"
|
||||
"ARCMVV0040AW","(mm) BSPT","(mm) BSPT","lpcompact4","MRA40A","0","0","LP",125,288,50,15,50,40,"0","GC2",450,225,356,0,0,595,,,"Fig 226","Flat Strainer","Vertical Down","Vertical Down",,"Actaris"
|
||||
"ARCMVV0040A","(mm) BSPT","(mm) BSPT","lpcompact4","MRA40A","0","0","LP",125,288,50,15,50,40,"RA0040LPB","Gas Cab No 2 (Multi)",450,225,356,0,0,595,,,"Fig 226","Flat Strainer","Vertical Down","Vertical Down",,"Actaris"
|
||||
"ARCMHH0065A","(mm) BSPT","(mm) PN16","lpvvhhcompact2","MRA65B","0","0","LP",105,800,80,15,105,50,"RA0065LPB","Gas Cab No 6",960,490,486,800,105,1424,,,"J90 ANGLED","Witches Hat Strainer","Horizontal Left","Horizontal Right",,"Actaris"
|
||||
"ARCMVV0065A","(mm) BSPT","(mm) PN16","lpvvhhcompact2","MRA65B","0","0","LP",105,500,80,15,163,50,"RA0065LPB","Gas Cab No 6",960,490,486,0,0,1424,,,"J90 ANGLED","Witches Hat Strainer","Vertical Down","Vertical Down",,"Actaris"
|
||||
"ARCMVH0065A","(mm) BSPT","(mm) PN16","lpvvhhcompact2","MRA65B","0","0","LP",105,500,80,15,105,50,"RA0065LPB","Gas Cab No 6",960,490,486,0,105,1424,,,"J90 ANGLED","Witches Hat Strainer","Vertical Down","Horizontal Right",,"Actaris"
|
||||
"ARCMHV0065A","(mm) BSPT","(mm) PN16","lpvvhhcompact2","MRA65B","0","0","LP",105,800,80,15,163,50,"RA0065LPB","Gas Cab No 6",960,490,486,800,0,1424,,,"J90 ANGLED","Witches Hat Strainer","Horizontal Left","Vertical Down",,"Actaris"
|
||||
"ARCMHH0100A","(mm) BSPT","(mm) PN16","lpvvhhcompact2","MRA100B","0","0","LP",105,800,80,15,105,50,"RA0100LPB","Gas Cab No 6",960,490,486,800,105,1424,,,"J90 ANGLED","Witches Hat Strainer","Horizontal Left","Horizontal Right",,"Actaris"
|
||||
"ARCMVV0100A","(mm) BSPT","(mm) PN16","lpvvhhcompact2","MRA100B","0","0","LP",105,500,80,15,163,50,"RA0100LPB","Gas Cab No 6",960,490,486,0,0,1424,,,"J90 ANGLED","Witches Hat Strainer","Vertical Down","Vertical Down",,"Actaris"
|
||||
"ARCMVH0100A","(mm) BSPT","(mm) PN16","lpvvhhcompact2","MRA100B","0","0","LP",105,500,80,15,105,50,"RA0100LPB","Gas Cab No 6",960,490,486,0,105,1424,,,"J90 ANGLED","Witches Hat Strainer","Vertical Down","Horizontal Right",,"Actaris"
|
||||
"ARCMHV0100A","(mm) BSPT","(mm) PN16","lpvvhhcompact2","MRA100B","0","0","LP",105,800,80,15,163,50,"RA0100LPB","Gas Cab No 6",960,490,486,800,0,1424,,,"J90 ANGLED","Witches Hat Strainer","Horizontal Left","Vertical Down",,"Actaris"
|
||||
"ARCMVV0160A","(mm) PN16","(mm) PN16","lpvvhhcompact1","MRA160C","0","0","LP",115,500,80,15,250,80,"RA0160LPB","Gas Cab No 6",960,490,486,0,0,1424,,,"J90 ANGLED","LOW LOSS STRAINER","Vertical Down","Vertical Down",,"Actaris"
|
||||
"ARCMHH0160A","(mm) PN16","(mm) PN16","lpvvhhcompact1","MRA160C","0","0","LP",115,800,80,15,124,80,"RA0160LPB","Gas Cab No 6",960,490,486,800,124,1424,,,"J90 ANGLED","LOW LOSS STRAINER","Horizontal Left","Horizontal Right",,"Actaris"
|
||||
"ARCMVH0160A","(mm) PN16","(mm) PN16","lpvvhhcompact1","MRA160C","0","0","LP",115,500,80,15,124,80,"RA0160LPB","Gas Cab No 6",960,490,486,0,124,1424,,,"J90 ANGLED","LOW LOSS STRAINER","Vertical Down","Horizontal Right",,"Actaris"
|
||||
"ARCMHV0160A","(mm) PN16","(mm) PN16","lpvvhhcompact1","MRA160C","0","0","LP",115,800,80,15,250,80,"RA0160LPB","Gas Cab No 6",960,490,486,800,0,1424,,,"J90 ANGLED","LOW LOSS STRAINER","Horizontal Left","Vertical Down",,"Actaris"
|
||||
"ARCMVV0200A","(mm) PN16","(mm) PN16","lpvvhhcompact1","MRA200C","0","0","LP",115,500,80,15,250,80,"RA0200LPB","Gas Cab No 6",960,490,486,0,0,1424,,,"J90 ANGLED","LOW LOSS STRAINER","Vertical Down","Vertical Down",,"Actaris"
|
||||
"ARCMHH0200A","(mm) PN16","(mm) PN16","lpvvhhcompact1","MRA200C","0","0","LP",115,800,80,15,124,80,"RA0200LPB","Gas Cab No 6",960,490,486,800,124,1424,,,"J90 ANGLED","LOW LOSS STRAINER","Horizontal Left","Horizontal Right",,"Actaris"
|
||||
"ARCMVH0200A","(mm) PN16","(mm) PN16","lpvvhhcompact1","MRA200C","0","0","LP",115,500,80,15,124,80,"RA0200LPB","Gas Cab No 6",960,490,486,0,124,1424,,,"J90 ANGLED","LOW LOSS STRAINER","Vertical Down","Horizontal Right",,"Actaris"
|
||||
"ARCMHV0200A","(mm) PN16","(mm) PN16","lpvvhhcompact1","MRA200C","0","0","LP",115,800,80,15,250,80,"RA0200LPB","Gas Cab No 6",960,490,486,800,0,1424,,,"J90 ANGLED","LOW LOSS STRAINER","Horizontal Left","Vertical Down",,"Actaris"
|
||||
"ARCMVV0250A","(mm) PN16","(mm) PN16","lpvvhhcompact1","MRA250C","0","0","LP",115,500,80,15,250,80,"RA0250LPB","GC7",960,490,486,0,0,1544,,,"J90 ANGLED","LOW LOSS STRAINER","Vertical Down","Vertical Down",,"Actaris"
|
||||
"ARCMHH0250A","(mm) PN16","(mm) PN16","lpvvhhcompact1","MRA250C","0","0","LP",115,800,80,15,124,80,"RA0250LPB","GC7",960,490,486,800,124,1544,,,"J90 ANGLED","LOW LOSS STRAINER","Horizontal Left","Horizontal Right",,"Actaris"
|
||||
"ARCMVH0250A","(mm) PN16","(mm) PN16","lpvvhhcompact1","MRA250C","0","0","LP",115,500,80,15,124,80,"RA0250LPB","GC7",960,490,486,0,124,1544,,,"J90 ANGLED","LOW LOSS STRAINER","Vertical Down","Horizontal Right",,"Actaris"
|
||||
"ARCMHV0250A","(mm) PN16","(mm) PN16","lpvvhhcompact1","MRA250C","0","0","LP",115,800,80,15,250,80,"RA0250LPB","GC7",960,490,486,800,0,1544,,,"J90 ANGLED","LOW LOSS STRAINER","Horizontal Left","Vertical Down",,"Actaris"
|
||||
"ARVV0250AP","(mm) PN16","(mm) PN16","lpvvhhcompact3","MRA250C","0","0","LP",175,500,100,15,277,80,"RA0250+LPB","GC8",1391,500,1082,0,0,1560,,,"Fig 226","LOW LOSS STRAINER","Vertical Down","Vertical Down",,"Actaris"
|
||||
"ARHH0250AP","(mm) PN16","(mm) PN16","lpvvhhcompact3","MRA250C","0","0","LP",175,800,100,15,152,80,"RA0250+LPB","GC8",1391,500,1082,800,152,1560,,,"Fig 226","LOW LOSS STRAINER","Horizontal Left","Horizontal Right",,"Actaris"
|
||||
"ARVH0250AP","(mm) PN16","(mm) PN16","lpvvhhcompact3","MRA250C","0","0","LP",175,500,100,15,152,80,"RA0250+LPB","GC8",1391,500,1082,0,152,1560,,,"Fig 226","LOW LOSS STRAINER","Vertical Down","Horizontal Right",,"Actaris"
|
||||
"ARHV0250AP","(mm) PN16","(mm) PN16","lpvvhhcompact3","MRA250C","0","0","LP",175,800,100,15,277,80,"RA0250+LPB","GC8",1391,500,1082,800,0,1560,,,"Fig 226","LOW LOSS STRAINER","Horizontal Left","Vertical Down",,"Actaris"
|
||||
"ARVV0300A","(mm) PN16","(mm) PN16","lplmvvhh1","MRA300D","0","0","LP",300,500,100,15,638,100,"RA0300LPB","GC8",2058,600,1838,0,0,1410,,,"Fig 226","LOW LOSS STRAINER","Vertical Down","Vertical Down",,"Actaris"
|
||||
"ARHH0300A","(mm) PN16","(mm) PN16","lplmvvhh1","MRA300D","0","0","LP",300,800,100,15,800,100,"RA0300LPB","GC8",2058,600,1838,800,800,1410,,,"Fig 226","LOW LOSS STRAINER","Horizontal Left","Horizontal Right",,"Actaris"
|
||||
"ARVH0300A","(mm) PN16","(mm) PN16","lplmvvhh1","MRA300D","0","0","LP",300,500,100,15,800,100,"RA0300LPB","GC8",2058,600,1838,0,800,1410,,,"Fig 226","LOW LOSS STRAINER","Vertical Down","Horizontal Right",,"Actaris"
|
||||
"ARHV0300A","(mm) PN16","(mm) PN16","lplmvvhh1","MRA300D","0","0","LP",300,800,100,15,638,100,"RA0300LPB","GC8",2058,600,1838,800,0,1410,,,"Fig 226","LOW LOSS STRAINER","Horizontal Left","Vertical Down",,"Actaris"
|
||||
"ARVV0300AP","(mm) PN16","(mm) PN16","lplmvvhh1","MRA300D","0","0","LP",400,500,150,15,638,100,"RA0300+LPB","Custom4",2342,700,2089,0,0,1492,,,"J48B","LOW LOSS STRAINER","Vertical Down","Vertical Down",,"Actaris"
|
||||
"ARHH0300AP","(mm) PN16","(mm) PN16","lplmvvhh1","MRA300D","0","0","LP",400,800,150,15,800,100,"RA0300+LPB","Custom4",2342,700,2089,800,800,1492,,,"J48B","LOW LOSS STRAINER","Horizontal Left","Horizontal Right",,"Actaris"
|
||||
"ARVH0300AP","(mm) PN16","(mm) PN16","lplmvvhh1","MRA300D","0","0","LP",400,500,150,15,800,100,"RA0300+LPB","Custom4",2342,700,2089,0,800,1492,,,"J48B","LOW LOSS STRAINER","Vertical Down","Horizontal Right",,"Actaris"
|
||||
"ARHV0300AP","(mm) PN16","(mm) PN16","lplmvvhh1","MRA300D","0","0","LP",400,800,150,15,638,100,"RA0300+LPB","Custom4",2342,700,2089,800,0,1492,,,"J48B","LOW LOSS STRAINER","Horizontal Left","Vertical Down",,"Actaris"
|
||||
"ARVV0400A","(mm) PN16","(mm) PN16","lplmvvhh1","MRA400D","0","0","LP",400,500,150,15,638,100,"RA0400LPB","Custom4",2324,700,1907,0,0,1613,,,"Fig 226","LOW LOSS STRAINER","Vertical Down","Vertical Down",,"Actaris"
|
||||
"ARHH0400A","(mm) PN16","(mm) PN16","lplmvvhh1","MRA400D","0","0","LP",400,800,150,15,800,100,"RA0400LPB","Custom4",2324,700,1907,800,800,1613,,,"Fig 226","LOW LOSS STRAINER","Horizontal Left","Horizontal Right",,"Actaris"
|
||||
"ARVH0400A","(mm) PN16","(mm) PN16","lplmvvhh1","MRA400D","0","0","LP",400,500,150,15,800,100,"RA0400LPB","Custom4",2324,700,1907,0,800,1613,,,"Fig 226","LOW LOSS STRAINER","Vertical Down","Horizontal Right",,"Actaris"
|
||||
"ARHV0400A","(mm) PN16","(mm) PN16","lplmvvhh1","MRA400D","0","0","LP",400,800,150,15,638,100,"RA0400LPB","Custom4",2324,700,1907,800,0,1613,,,"Fig 226","LOW LOSS STRAINER","Horizontal Left","Vertical Down",,"Actaris"
|
||||
"ARVV0650A","(mm) PN16","(mm) PN16","lplmvvhh1","MRA650E","0","0","LP",470,500,150,15,562,150,"RA0650LPB","Custom5",2861,726,2576,0,0,1492,,,"J48","LOW LOSS STRAINER","Vertical Down","Vertical Down",,"Actaris"
|
||||
"ARHH0650A","(mm) PN16","(mm) PN16","lplmvvhh1","MRA650E","0","0","LP",470,800,150,15,800,150,"RA0650LPB","Custom5",2861,726,2576,800,800,1492,,,"J48","LOW LOSS STRAINER","Horizontal Left","Horizontal Right",,"Actaris"
|
||||
"ARVH0650A","(mm) PN16","(mm) PN16","lplmvvhh1","MRA650E","0","0","LP",470,500,150,15,800,150,"RA0650LPB","Custom5",2861,726,2576,0,800,1492,,,"J48","LOW LOSS STRAINER","Vertical Down","Horizontal Right",,"Actaris"
|
||||
"ARHV0650A","(mm) PN16","(mm) PN16","lplmvvhh1","MRA650E","0","0","LP",470,800,150,15,562,150,"RA0650LPB","Custom5",2861,726,2576,800,0,1492,,,"J48","LOW LOSS STRAINER","Horizontal Left","Vertical Down",,"Actaris"
|
||||
"ARVV0650AP","(mm) PN16","(mm) PN16","lplmvvhh1","MRA650E","0","0","LP",800,500,150,15,561,150,"RA0650+LPB","Custom6",3219,1322,2776,0,0,1492,,,"J48B","LOW LOSS STRAINER","Vertical Down","Vertical Down",,"Actaris"
|
||||
"ARHH0650AP","(mm) PN16","(mm) PN16","lplmvvhh1","MRA650E","0","0","LP",800,800,150,15,800,150,"RA0650+LPB","Custom6",3219,1322,2776,800,800,1492,,,"J48B","LOW LOSS STRAINER","Horizontal Left","Horizontal Right",,"Actaris"
|
||||
"ARVH0650AP","(mm) PN16","(mm) PN16","lplmvvhh1","MRA650E","0","0","LP",800,500,150,15,800,150,"RA0650+LPB","Custom6",3219,1322,2776,0,800,1492,,,"J48B","LOW LOSS STRAINER","Vertical Down","Horizontal Right",,"Actaris"
|
||||
"ARHV0650AP","(mm) PN16","(mm) PN16","lplmvvhh1","MRA650E","0","0","LP",800,800,150,15,561,150,"RA0650+LPB","Custom6",3219,1322,2776,800,0,1492,,,"J48B","LOW LOSS STRAINER","Horizontal Left","Vertical Down",,"Actaris"
|
||||
"ARVV1000A","(mm) PN16","(mm) PN16","lplmvvhh1","MRA1000SE","0","0","LP",620,500,150,15,562,150,"RA1000LPB","Custom5",2800,825,2515,0,0,1613,,,"Fig 226","LOW LOSS STRAINER","Vertical Down","Vertical Down",,"Actaris"
|
||||
"ARHH1000A","(mm) PN16","(mm) PN16","lplmvvhh1","MRA1000SE","0","0","LP",620,800,150,15,800,150,"RA1000LPB","Custom5",2800,825,2515,800,800,1613,,,"Fig 226","LOW LOSS STRAINER","Horizontal Left","Horizontal Right",,"Actaris"
|
||||
"ARVH1000A","(mm) PN16","(mm) PN16","lplmvvhh1","MRA1000SE","0","0","LP",620,500,150,15,800,150,"RA1000LPB","Custom5",2800,825,2515,0,800,1613,,,"Fig 226","LOW LOSS STRAINER","Vertical Down","Horizontal Right",,"Actaris"
|
||||
"ARHV1000A","(mm) PN16","(mm) PN16","lplmvvhh1","MRA1000SE","0","0","LP",620,800,150,15,562,150,"RA1000LPB","Custom5",2800,825,2515,800,0,1613,,,"Fig 226","LOW LOSS STRAINER","Horizontal Left","Vertical Down",,"Actaris"
|
||||
"ARVV1000AP","(mm) PN16","(mm) PN16","lplmvvhh1","MRA1000+","0","0","LP",1000,500,150,15,561,150,"RA1000+LPB","Custom6",3245,1345,2801,0,0,1613,,,"Fig 226","LOW LOSS STRAINER","Vertical Down","Vertical Down",,"Actaris"
|
||||
"ARHH1000AP","(mm) PN16","(mm) PN16","lplmvvhh1","MRA1000+","0","0","LP",1000,800,150,15,800,150,"RA1000+LPB","Custom6",3245,1345,2801,800,800,1613,,,"Fig 226","LOW LOSS STRAINER","Horizontal Left","Horizontal Right",,"Actaris"
|
||||
"ARVH1000AP","(mm) PN16","(mm) PN16","lplmvvhh1","MRA1000+","0","0","LP",1000,500,150,15,800,150,"RA1000+LPB","Custom6",3245,1345,2801,0,800,1613,,,"Fig 226","LOW LOSS STRAINER","Vertical Down","Horizontal Right",,"Actaris"
|
||||
"ARHV1000AP","(mm) PN16","(mm) PN16","lplmvvhh1","MRA1000+","0","0","MP270",1000,800,150,15,561,150,"RA1000+LPB","Custom6",3245,1345,2801,800,0,1613,,,"Fig 226","LOW LOSS STRAINER","Horizontal Left","Vertical Down",,"Actaris"
|
||||
"ASD016A","(mm) BSPT","(mm) BSPT","mpvvstddia","MDA16","Integral","Integral","MP270",30,265,20,21,337,40,"U016MPB","Gas Cab No 2MP",483,346,363,0,0,653,,,"RBI 2011","Y Type","Vertical Down","Vertical Up",,"Actaris"
|
||||
"ASD025A","(mm) BSPT","(mm) BSPT","mpvvstddia","MDA25","Integral","Integral","MP270",40,265,25,21,471,50,"U025MPB","GC4+",797,308,579,0,0,854,,,"RBI 2111","Y Type","Vertical Down","Vertical Up",,"Actaris"
|
||||
"ASD040A","(mm) BSPT","(mm) BSPT","mpvvstddia","MDA40","Integral","Integral","MP270",60,265,25,21,649,50,"U040MPB","GC4+",875,381,678,0,0,954,,,"RBE2611","Y Type","Vertical Down","Vertical Up",,"Actaris"
|
||||
"ASD065A","(mm) PN16","(mm) BSPT","mpvvstddia","MDA65","Integral","Integral","MP270",98,265,50,21,1106,80,"U065MPB","Gas Cab No 6",1072,385,762,0,0,1117,,,"RBI 3211","Y Type","Vertical Down","Vertical Up",,"Actaris"
|
||||
"ASD100A","(mm) PN16","(mm) BSPT","mpvvstddia","MDA100","VS811","Integral","MP270",137,265,50,21,957,80,"U100MPB","Gas Cab No 6",1180,601,828,0,0,1341,,,"RBE 4011","Y Type","Vertical Down","Vertical Up",,"Actaris"
|
||||
"ASD160A","(mm) PN16","(mm) BSPT","mpvvstddia","MDA160","VS811","Integral","MP270",193,265,50,21,1000,100,"U160MPB","Gas Cab No 6",1301,645,816,0,0,1324,,,"RBE1811","Y Type","Vertical Down","Vertical Up",,"Actaris"
|
||||
"ASR0025A","(mm) BSPT","(mm) BSPT","actmp1","MRA25A","Integral","Integral","MP270",50,265,25,21,225,40,"RA0025MPB","Gas Cab No 2 (Multi)",627,260,400,0,0,711,,,"RBI 2111","Y Type","Vertical Down","Vertical Down",,"Actaris"
|
||||
"ASR0040A","(mm) BSPT","(mm) BSPT","actmp1","MRA40A","Integral","Integral","MP270",55,265,25,21,303,40,"RA0040MPB","GC4+",861,260,686,0,0,672,,,"RBI 2611","Y Type","Vertical Down","Vertical Down",,"Actaris"
|
||||
"ASR0100A","(mm) BSPT","(mm) BSPT","actmp2","MRA100B","VS811","Integral","MP270",70,265,50,21,316,50,"RA0100MPB","GC5",1070,484,800,0,0,1268,,,"RBE 4011","Y Type","Vertical Down","Vertical Down",,"Actaris"
|
||||
"ASR0160A","(mm) PN16","(mm) BSPT","actmp3","MRA160C","VS811","Integral","MP270",100,265,50,21,101,80,"RA0160MPB","GC8",1470,450,1280,0,0,1210,,,"RBE1811","Angle Pattern","Vertical Down","Vertical Down",,"Actaris"
|
||||
"ASR0200A","(mm) PN16","(mm) BSPT","actmp4","MRA200C","VS811","Integral","MP270",100,265,50,21,102,80,"RA0200MPB","GC8",1413,496,1223,0,0,1198,,,"RBE1811","Angle Pattern","Vertical Down","Vertical Down",,"Actaris"
|
||||
"ASR0250A","(mm) PN16","(mm) PN16","actmp4","MRA250C","VS811","Integral","MP270",160,500,80,21,222,80,"RA0250MPB","GC8",1446,495,1240,0,0,1392,,,"RBE1811","Angle Pattern","Vertical Down","Vertical Down",,"Actaris"
|
||||
"ASR0300A","(mm) PN16","(mm) PN16","actmp4","MRA300D","VS811","Integral","MP270",350,500,80,21,200,100,"RA0300MPB","GC8",1537,585,1310,0,0,1365,,,"RBE 4011","Angle Pattern","Vertical Down","Vertical Down",,"Actaris"
|
||||
"ASR0400A","(mm) PN16","(mm) PN16","actmp5","MRA400D","VS811","Integral","MP270",375,500,80,21,104,100,"RA0400MPB","GC8",1537,749,1310,0,0,1400,,,"RBE 4011","Angle Pattern","Vertical Down","Vertical Down",,"Actaris"
|
||||
"ASR0650A","(mm) PN16","(mm) PN16","actmp6","MRA650SE","VS811","Integral","MP270",500,500,100,21,151,150,"RA0650MPB","Custom2",1832,765,1467,0,0,1918,,,"RBE 4011","Angle Pattern","Vertical Down","Vertical Down",,"Actaris"
|
||||
"ASR1000A","(mm) PN16","(mm) PN16","actmp7","MRA1000SE","VS811","Integral","MP270",750,500,150,21,85,150,"RA1000MPB","Custom3",1843,848,1515,0,0,2067,,,"RBE 4011","Angle Pattern","Vertical Down","Vertical Down",,"Actaris"
|
||||
"ASR0025D"," 2"" BSPT","1.5"" BSPT","dremp1","MRD0025B4B","Integral","Integral","MP270",65,265,40,21,200,50,"RD0025MPB","GC4+",760,375,500,0,0,1130,,,"Donkin Fig 270R/309LP","Y Type","Vertical Down","Vertical Down",,"Dresser"
|
||||
"ASR0040D","(mm) BSPT","(mm) BSPT","dremp1","MRD0040B4B","Integral","Integral","MP270",65,265,40,21,340,50,"RD0040MPB","GC4+",825,550,550,0,0,1122,,,"Donkin Fig 270R/309LP","Y Type","Vertical Down","Vertical Down",,"Dresser"
|
||||
"ASR0065D","(mm) BSPT","(mm) BSPT","dremp1","MRD0065B4B","Integral","Integral","MP270",65,265,40,21,340,50,"RD0065MPB","GC4+",825,550,550,0,0,1125,,,"Donkin Fig 270R/309LP","Y Type","Vertical Down","Vertical Down",,"Dresser"
|
||||
"ASR0100D","(mm) BSPT","(mm) BSPT","dremp1","MRD0100B4B","Integral","Integral","MP270",65,265,40,21,340,50,"RD0100MPB","GC4+",825,550,550,0,0,1125,,,"Donkin Fig 270R/309LP","Y Type","Vertical Down","Vertical Down",,"Dresser"
|
||||
"ASR0160D","(mm) PN16","(mm) PN16","nodraw1","MRD0160B4C","Integral","Integral","MP270",84,150,50,21,150,80,"RD0160MPB",,160,640,120,200,420,1250,,,"Donkin Fig 270R","Y Type","Vertical Down","Vertical Down",,"Dresser"
|
||||
"ASR0250D","(mm) PN16","(mm) PN16","dremp2","MRD0250B4D","10L","Integral","MP270",270,500,80,21,250,80,"RD0250MPB","GC8",1490,600,1192,0,0,1550,,,"Donkin Fig 280/309","Angle Pattern","Vertical Down","Vertical Down",,"Dresser"
|
||||
"ASR0310D","(mm) PN16","(mm) PN16","dremp2","MRD0310B4D","10L","Integral","MP270",280,500,80,21,250,100,"RD0310MPB","GC8",1490,600,1205,0,0,1550,,,"Donkin Fig 280/309","Angle Pattern","Vertical Down","Vertical Down",,"Dresser"
|
||||
"ASR0450D","(mm) PN16","(mm) PN16","dremp3","MRD0450B4D","10L","Donkin Fig 305","MP270",410,500,80,21,340,100,"RD0450MPB","Custom1",2035,750,400,0,0,1450,,,"Donkin Fig 280","Angle Pattern","Vertical Down","Vertical Down",,"Dresser"
|
||||
"ASR0450DP","(mm) PN16","(mm) PN16","dremp3","MRD0450B4D","10L","Donkin Fig 305","MP270",425,500,100,21,435,100,"RD0450+MPB","Custom1",2070,750,400,0,0,1545,,,"Donkin Fig 280","Angle Pattern","Vertical Down","Vertical Down",,"Dresser"
|
||||
"ASR0650D","(mm) PN16","(mm) PN16","dremp3","MRD0650B4E","10L","Donkin Fig 305","MP270",600,500,100,21,215,150,"RD0650MPB","Custom4",2450,800,400,0,0,1590,,,"Donkin Fig 280","Angle Pattern","Vertical Down","Vertical Down",,"Dresser"
|
||||
"ASR1075D","(mm) PN16","(mm) PN16","dremp4","MRD1075B4E","10L","Donkin Fig 305","MP270",750,500,150,21,200,150,"RD1075MPB","Custom5",2720,796,400,0,0,1725,,,"Donkin Fig 280","Angle Pattern","Vertical Down","Vertical Down",,"Dresser"
|
||||
"ASR1600D","(mm) PN16","(mm) PN16","dremp3","MRD1600B4F","10L","Donkin Fig 305","MP270",1000,500,150,21,200,200,"RD1600MPB","Custom5",2970,925,450,0,0,1900,,,"Donkin Fig 280","Angle Pattern","Vertical Down","Vertical Down",,"Dresser"
|
||||
"ASR2885D","(mm) PN16","(mm) PN16","nodraw1","MRD2885A10","10L","Donkin Fig 305","MP270",1680,463,200,21,160,250,"RD2885MPB",,275,550,2625,750,750,1895,,,"Donkin Fig 280","Angle Pattern","Vertical Down","Vertical Down",,"Dresser"
|
||||
"Meter Only (Notes)",,,"nodraw1",,,,"MP270",,,,,,,,,,,,,,,,,,,,,,
|
||||
"ASD016AW","(mm) BSPT","(mm) BSPT","mpvvstddia","MDA16","Integral","Integral",,30,265,20,21,337,40,"U016MPB","GC2MP",483,346,363,0,0,653,,,"RBI 2011","Y Type","Vertical Down","Vertical Up",,"Actaris"
|
||||
|
||||
|
15170
Data/BulkLoad/POSTCODES.csv
Normal file
15170
Data/BulkLoad/POSTCODES.csv
Normal file
File diff suppressed because it is too large
Load Diff
@@ -14,43 +14,41 @@ SECOND_CONTACT_FAX,Contact Address.Fax,O,O,O,O,O,O,O,O,O,O,O,O
|
||||
FIRST_ALT_POSTCODE,Contact Address.Post Code,O,O,O,O,O,O,O,O,O,O,O,O
|
||||
SECOND_CONTACT_NAME,Contact Address.Second Contact Name,O,O,O,O,O,O,O,O,O,O,O,O
|
||||
FIRST_ALT_STREET,Contact Address.Street,O,O,O,O,O,O,O,O,O,O,O,O
|
||||
FIRST_ALT_SUB_BUILDING,Contact Address.Sub Building,O,O,O,O,O,O,O,O,O,O,O,O
|
||||
FIRST_CONTACT_TELEPHONE_1,Contact Address.Telephone1,M,M,M,M,M,M,M,M,M,M,M,M
|
||||
SECOND_CONTACT_TELEPHONE_1,Contact Address.Telephone1,O,O,O,O,O,O,O,O,O,O,O,O
|
||||
FIRST_CONTACT_TELEPHONE_2,Contact Address.Telephone2,O,O,O,O,O,O,O,O,O,O,O,O
|
||||
SECOND_CONTACT_TELEPHONE_2,Contact Address.Telephone2,O,O,O,O,O,O,O,O,O,O,O,O
|
||||
AMR_REQUIRED,Job Information.Additional Services.AMR,M,M,M,M,M,M,M,M,M,M,M,M
|
||||
BASE_REQUIRED,Job Information.Additional Services.Base,M,M,M,M,M,M,M,M,M,M,M,M
|
||||
BYPASS_REQUIRED,Job Information.Additional Services.By-pass,M,M,M,M,M,M,M,M,M,M,M,M
|
||||
CONVERTOR_REQUIRED,Job Information.Additional Services.Convertor,M,M,M,M,M,M,M,M,M,M,M,M
|
||||
EMS_REQUIRED,Job Information.Additional Services.EMS,M,M,M,M,M,M,M,M,M,M,M,M
|
||||
HOUSING_REQUIRED,Job Information.Additional Services.Housing,M,M,M,M,M,M,M,M,M,M,M,M
|
||||
LOGGER_REQUIRED,Job Information.Additional Services.Logger,M,M,M,M,M,M,M,M,M,M,M,M
|
||||
TWIN_STREAM_REQUIRED,Job Information.Additional Services.Twin Stream,O,O,O,O,O,O,O,O,O,O,O,O
|
||||
ANNUAL_QUANTITY,Job Information.Annual Quantity,M,M,M,M,M,M,M,M,M,M,M,M
|
||||
INDICATIVE_TIME,Job Information.Appointment Preference,O,O,O,O,O,O,O,O,O,O,O,O
|
||||
DOWNSTREAM_BOOSTER_OR_COMPRESS,Job Information.Booster/Compressor,M,O,M,M,O,M,O,M,M,M,M,M
|
||||
EXISTING_METER_SERIAL_NO,Job Information.Existing Asset Serial Number,NA,NA,M,M,M,M,M,O,M,O,M,O
|
||||
EXISTING_MESC_CODE,Job Information.Existing Meter Size,NA,NA,M,M,M,M,M,M,M,M,O,O
|
||||
METY_CODE,Job Information.Meter Type Existing ,NA,NA,M,M,M,M,M,M,M,M,O,O
|
||||
EXISTING_SVCP_CODE,Job Information.Existing Pressure Category,NA,NA,M,M,M,M,M,M,M,M,O,O
|
||||
EXISTING_METER_OWNER,Job Information.Gas Act Owner,O,O,O,M,M,M,M,O,O,O,O,O
|
||||
INDICATIVE_DATE,Job Information.Indicative Substantial Completion Date,O,O,O,O,O,O,O,O,O,O,O,O
|
||||
REQUIRED_IP_DETAILS,Job Information.IP Details,M3,NA,O3,O3,NA,O3,NA,O3,M3,M3,O3,O3
|
||||
REQUIRED_IP_MBAR,Job Information.IP Mbar,O3,NA,O3,O3,NA,O3,NA,O3,O3,O3,O3,O3
|
||||
JOB_DESCRIPTION,Job Information.Job Description,O,O,O,O,O,O,O,O,O,O,O,O
|
||||
ENTY_CODE,Job Information.Job Type,M,M,M,M,M,M,M,M,M,M,M,M
|
||||
LOAD_CONTROL_TYPE,Job Information.Load Control Type,M,M,O,M,M,O,O,O,O,O,O,O
|
||||
MARKET_SECTOR_CODE,Job Information.Market Sector Code,O,O,O,O,O,O,O,O,O,O,O,O
|
||||
QMAX,Job Information.Measuring Capacity Qmax,M,M2,M,M,M,M,M,M,M,M,M,M
|
||||
QMIN,Job Information.Measuring Capacity Qmin,O,O,O,O,O,O,O,O,O,O,O,O
|
||||
REQUIRED_MESC_CODE,Job Information.Meter Size,NA,OM2,NA,NA,NA,NA,NA,NA,NA,NA,NA,NA
|
||||
EXISTING_METER_MODEL,Job Information.Model Code,NA,NA,O,O,O,O,O,O,O,O,O,O
|
||||
OTHER_INFORMATION,Job Information.Other Information,O,O,O,O,O,O,O,O,O,O,O,O
|
||||
OTHER_PROJECT_REFERENCE,Job Information.Other Related Projects,O,O,O,O,O,O,O,O,O,O,O,O
|
||||
REQUIRED_METERING_PRESSURE,Job Information.Required Meter Pressure,M,M,M,M,M,M,M,M,M,M,M,M
|
||||
REQUIRED_SVCP_CODE,Job Information.Service Pressure,M3,M,O3,O3,M,O3,M,O3,M3,M3,O3,O3
|
||||
EXISTING_METER_ASSET_PROVIDER,Job Information.Supplier / Job Information.Consumer,O,O,O,M,M,M,M,O,M,O,O,O
|
||||
FIRST_ALT_SUB_BUILDING,Contact Address.Sub Building,O,O,O,O,O,O,O,O,O,O,O,O,
|
||||
FIRST_CONTACT_TELEPHONE_1,Contact Address.Telephone1,M,M,M,M,M,M,M,M,M,M,M,M,
|
||||
SECOND_CONTACT_TELEPHONE_1,Contact Address.Telephone1,O,O,O,O,O,O,O,O,O,O,O,O,
|
||||
FIRST_CONTACT_TELEPHONE_2,Contact Address.Telephone2,O,O,O,O,O,O,O,O,O,O,O,O,
|
||||
SECOND_CONTACT_TELEPHONE_2,Contact Address.Telephone2,O,O,O,O,O,O,O,O,O,O,O,O,
|
||||
AMR_REQUIRED,Job Information.Additional Services.AMR,M,M,H,M,M,H,H,H,M,M,M,M,"The AMR may only be available for the Tripartite suppliers or BG, GW to confirm!"
|
||||
BASE_REQUIRED,Job Information.Additional Services.Base,M,M,H,M,M,H,H,H,M,M,H,M,
|
||||
BYPASS_REQUIRED,Job Information.Additional Services.By-pass,O,O,H,O,O,H,H,H,O,O,O,O,"If yes, warn user if twin stream is no"
|
||||
CONVERTOR_REQUIRED,Job Information.Additional Services.Convertor,M,M,H,M,M,M,M,M,M,M,M,M,this can be an add-on for removals
|
||||
EMS_REQUIRED,Job Information.Additional Services.EMS,M,M,H,M,M,H,H,H,M,M,M,M,
|
||||
HOUSING_REQUIRED,Job Information.Additional Services.Housing,M,M,H,M,M,H,H,H,M,M,H,M,
|
||||
TWIN_STREAM_REQUIRED,Job Information.Additional Services.Twin Stream,M,M,H,M,M,H,H,H,M,M,H,M,
|
||||
ANNUAL_QUANTITY,Job Information.Annual Quantity,O,O,O,O,O,H,H,H,O,O,O,O,if > 732 mwh go bespoke
|
||||
INDICATIVE_TIME,Job Information.Appointment Preference,O,O,O,O,O,O,O,O,O,O,O,O,
|
||||
DOWNSTREAM_BOOSTER_OR_COMPRESS,Job Information.Booster/Compressor,M,M,M,M,M,H,H,H,M,M,M,M,
|
||||
EXISTING_METER_SERIAL_NO,Job Information.Existing Asset Serial Number,H,H,M,M,M,M,M,M,M,M,M,O,
|
||||
EXISTING_MESC_CODE,Job Information.Existing Meter Size,H,H,M,M,M,M,M,M,M,M,O,O,
|
||||
METY_CODE,Job Information.Meter Type Existing ,H,H,M,M,M,M,M,M,M,M,O,O,
|
||||
EXISTING_METER_OWNER,Job Information.Gas Act Owner,O,O,M,M,M,M,M,M,M,M,M,O,
|
||||
INDICATIVE_DATE,Job Information.Indicative Substantial Completion Date,O,O,O,O,O,O,O,O,O,O,O,O,
|
||||
REQUIRED_IP_DETAILS,Job Information.IP Details,O3,H,O3,O3,H,O3,H,O3,M3,M3,O3,O3,if service pressure is IP
|
||||
REQUIRED_IP_MBAR,Job Information.IP Mbar,M3,H,O3,M3,H,O3,H,O3,O3,M3,O3,O3,if service pressure is IP
|
||||
JOB_DESCRIPTION,Job Information.Job Description,O,O,O,O,O,O,O,O,O,O,O,O,
|
||||
ENTY_CODE,Job Information.Job Type,M,M,M,M,M,M,M,M,M,M,M,M,
|
||||
LOAD_CONTROL_TYPE,Job Information.Load Control Type,M,M,H,M,M,H,H,H,O,M,O,O,
|
||||
MARKET_SECTOR_CODE,Job Information.Market Sector Code,O,O,O,O,O,O,O,O,O,O,O,O,
|
||||
QMAX,Job Information.Measuring Capacity Qmax,M,M2,O,M,M2,O,O,O,O,M,O,O,
|
||||
QMIN,Job Information.Measuring Capacity Qmin,O,O,O,O,O,O,O,O,O,O,O,O,
|
||||
REQUIRED_MESC_CODE,Job Information.Meter Size,H,OM2,H,H,OM2,H,H,H,H,O,H,O,
|
||||
EXISTING_METER_MODEL,Job Information.Model Code,H,H,O,O,O,O,O,O,O,O,O,O,
|
||||
OTHER_INFORMATION,Job Information.Other Information,O,O,O,O,O,O,O,O,O,O,O,O,
|
||||
OTHER_PROJECT_REFERENCE,Job Information.Other Related Projects,O,O,O,O,O,O,O,O,O,O,O,O,
|
||||
REQUIRED_METERING_PRESSURE,Job Information.Required Meter Pressure,M,M,M,M,M,M,M,M,M,M,O,O
|
||||
REQUIRED_SVCP_CODE,Job Information.Service Pressure,M3,M,M3,M3,M,M3,M,M3,M3,M3,O3,O3
|
||||
EXISTING_METER_ASSET_PROVIDER,Job Information.Supplier / Job Information.Consumer(Meter Asset Manager),O,O,O,O,O,O,O,O,O,O,O,O
|
||||
TRANSACTION_REFERENCE,Job Site Details.Transaction Reference,O,O,O,O,O,O,O,O,O,O,O,O
|
||||
SECOND_ALT_BUILDING,Second Contact Address.Building,O,O,O,O,O,O,O,O,O,O,O,O
|
||||
SECOND_ALT_CITY,Second Contact Address.City,O,O,O,O,O,O,O,O,O,O,O,O
|
||||
@@ -59,15 +57,18 @@ SECOND_ALT_STREET,Second Contact Address.Street,O,O,O,O,O,O,O,O,O,O,O,O
|
||||
SECOND_ALT_SUB_BUILDING,Second Contact Address.Sub Building,O,O,O,O,O,O,O,O,O,O,O,O
|
||||
ACCESS_ADDITIONAL,Site Detail.Access Instructions,O,O,O,O,O,O,O,O,O,O,O,O
|
||||
ACCESS_PASSWORD,Site Detail.Access Password,O,O,O,O,O,O,O,O,O,O,O,O
|
||||
MPRN_ALT,Site Detail.Additional Information,M4,M4,M4,M4,M4,M4,M4,M4,M4,M4,M4,M4
|
||||
MPRN_ALT,Site Detail.Additional Information,M4,M4,O,O,O,O,O,O,O,O,O,O
|
||||
ALTY_CODE,Site Detail.Asset Location Code,M,M,M,M,M,M,M,M,M,M,M,M
|
||||
ASSET_LOCATION_NOTES,Site Detail.Asset Location Notes,O,O,O,O,O,O,O,O,O,O,O,O
|
||||
CACA_CODE,Site Detail.Care Category,O,O,O,O,O,O,O,O,O,O,O,O
|
||||
MPRN,Site Detail.MPRN,M4,M4,M4,M4,M4,M4,M4,M4,M4,M4,M4,M4
|
||||
MPRN,Site Detail.MPRN,OM4,OM4,M,M,M,M,M,M,M,M,M,O
|
||||
AGENT_COMT_CODE,Supplier Agent.Telephone1/Telephone2/Fax/Email,M,M,M,M,M,M,M,M,M,M,M,M
|
||||
AGENT_CONTACT_VALUE,Supplier Agent.Telephone1/Telephone2/Fax/Email,M,M,M,M,M,M,M,M,M,M,M,M
|
||||
ID,Enquiry Reference (not in spec appendix),M,M,M,M,M,M,M,M,M,M,M,M
|
||||
CREATED_BY,,,,,,,,,,,,,
|
||||
CREATED_ON,,,,,,,,,,,,,
|
||||
UPDATED_BY,,,,,,,,,,,,,
|
||||
UPDATED_ON,,,,,,,,,,,,,
|
||||
LOGGER_REQUIRED,Job Information.Logger,H,H,H,O,O,O,O,O,O,O,O,O
|
||||
,,,,,,,,,,,,,
|
||||
,,,,,,,,,,,,,
|
||||
,,,,,,,,,,,,,
|
||||
,,,,,,,,,,,,,
|
||||
,Tripartite,Y,Y,Y,Y,Y,Y,Y,Y,Don't care,Don't care,Y,Don't care
|
||||
,Non-Tripartite,N,N,Y,N,N,Y,Y,Y,Don't care,Don't care,Y,Don't care
|
||||
|
||||
|
@@ -26,32 +26,18 @@ sqlldr %1 control=enst
|
||||
|
||||
sqlldr %1 control=enty
|
||||
|
||||
sqlldr %1 control=fity
|
||||
|
||||
sqlldr %1 control=hoty
|
||||
|
||||
sqlldr %1 control=mety
|
||||
|
||||
sqlldr %1 control=prtp
|
||||
|
||||
sqlldr %1 control=qust
|
||||
|
||||
sqlldr %1 control=rety
|
||||
|
||||
sqlldr %1 control=rvty
|
||||
|
||||
sqlldr %1 control=svcpt
|
||||
|
||||
sqlldr %1 control=svcp
|
||||
|
||||
sqlldr %1 control=slty
|
||||
|
||||
sqlldr %1 control=cnty
|
||||
|
||||
sqlldr %1 control=cnor
|
||||
|
||||
sqlldr %1 control=slva
|
||||
|
||||
sqlldr %1 control=caca
|
||||
|
||||
sqlldr %1 control=mesc
|
||||
@@ -62,13 +48,12 @@ sqlldr %1 control=dir_import
|
||||
|
||||
sqlldr %1 control=regi
|
||||
|
||||
sqlldr %1 control=poco
|
||||
|
||||
sqlldr %1 control=syco
|
||||
|
||||
sqlldr %1 control=adit
|
||||
|
||||
sqlplus %1 @enable_constraints
|
||||
|
||||
sqlplus %1 @create_passwords
|
||||
|
||||
goto :done
|
||||
|
||||
|
||||
@@ -5,19 +5,20 @@ REPLACE
|
||||
FIELDS TERMINATED BY '|'
|
||||
(
|
||||
code
|
||||
,description
|
||||
,qmax
|
||||
,valid_for_new_meter
|
||||
,valid_for_existing_meter
|
||||
,valid_for_new_meter
|
||||
)
|
||||
BEGINDATA
|
||||
U16|12.8|YES|YES
|
||||
U25|20|YES|YES
|
||||
U40|32|YES|YES
|
||||
U65|52|YES|YES
|
||||
U100|80|YES|YES
|
||||
U160|128|YES|YES
|
||||
Rotary/Turbine 2"|999|NO|YES
|
||||
Rotary/Turbine 3"|9999|NO|YES
|
||||
Rotary/Turbine 4"|99999|NO|YES
|
||||
Rotary/Turbine 6"|999999|NO|YES
|
||||
Other|9999999|NO|YES
|
||||
U16|U16|12.8|YES|YES
|
||||
U25|U25|20|YES|YES
|
||||
U40|U40|32|YES|YES
|
||||
U65|U65|52|YES|YES
|
||||
U100|U100|80|YES|YES
|
||||
U160|U160|128|YES|YES
|
||||
Rotary/Turbine 2"|Rotary/Turbine 2"|999|YES|NO
|
||||
Rotary/Turbine 3"|Rotary/Turbine 3"|9999|YES|NO
|
||||
Rotary/Turbine 4"|Rotary/Turbine 4"|99999|YES|NO
|
||||
Rotary/Turbine 6"|Rotary/Turbine 6"|999999|YES|NO
|
||||
Other|Other|9999999|YES|YES
|
||||
|
||||
17
Data/Seed/adit.ctl
Normal file
17
Data/Seed/adit.ctl
Normal file
@@ -0,0 +1,17 @@
|
||||
LOAD DATA
|
||||
INFILE *
|
||||
INTO TABLE additional_items
|
||||
REPLACE
|
||||
FIELDS TERMINATED BY '|'
|
||||
(
|
||||
code
|
||||
,description
|
||||
,lead_time
|
||||
)
|
||||
BEGINDATA
|
||||
BYPASS|Bypass|9999
|
||||
LOGGER|Data Logger|15
|
||||
AMR|Automatic Meter Reading|15
|
||||
EMS|Energy Management System|15
|
||||
PURGING|Purging (if required) (On Time and Materials Basis)|0
|
||||
LIFTING GEAR|Lifting Gear (if required) (Per Day)|0
|
||||
@@ -10,9 +10,17 @@ rt_code
|
||||
,privilege
|
||||
)
|
||||
BEGINDATA
|
||||
MIPADMIN|adminmenu|C|A
|
||||
SUPPADMIN|adminmenu|C|A
|
||||
MIPADMIN|10|P|A
|
||||
MIPADMIN|32|P|A
|
||||
MIPADMIN|21|P|A
|
||||
MIPADMIN|20|P|A
|
||||
MIPADMIN|13|P|A
|
||||
AGENT|11|P|A
|
||||
CS|11|P|A
|
||||
MIPADMIN|11|P|A
|
||||
MIPADMIN|13|P|A
|
||||
MIPADMIN|20|P|A
|
||||
MIPADMIN|21|P|A
|
||||
AGENT|32|P|A
|
||||
CS|32|P|A
|
||||
ICU|32|P|A
|
||||
MIPADMIN|32|P|A
|
||||
CS|32|P|R
|
||||
|
||||
@@ -1,13 +0,0 @@
|
||||
LOAD DATA
|
||||
INFILE *
|
||||
INTO TABLE connection_types
|
||||
REPLACE
|
||||
FIELDS TERMINATED BY '|'
|
||||
(
|
||||
description
|
||||
,code
|
||||
)
|
||||
BEGINDATA
|
||||
(mm) BSPT|MMBSTP
|
||||
(mm) PN16|MMPN16
|
||||
INCH BS 746|INCHBS
|
||||
@@ -14,7 +14,7 @@ OFMAT|Request for OFGEM Meter Accuracy Test (OFMAT)
|
||||
EXCHANGE|Exchange of non-Standard meter
|
||||
REMOVE|Removal of non-Standard meter
|
||||
STD REMOVE|Removal of a Standard meter
|
||||
RELOCATE|Relocation of a meter
|
||||
ALTERATION|Alteration (relocation or reposition) of an existing meter
|
||||
ADDON|Purchase of standard add-ons for an existing meter module
|
||||
OTHER|Other
|
||||
CHANGE CAPACITY|Change of capacity
|
||||
|
||||
@@ -1,16 +0,0 @@
|
||||
LOAD DATA
|
||||
INFILE *
|
||||
INTO TABLE filter_types
|
||||
REPLACE
|
||||
FIELDS TERMINATED BY '|'
|
||||
(
|
||||
code
|
||||
,description
|
||||
)
|
||||
BEGINDATA
|
||||
LOW LOSS STRAINER|Low Loss Strainer
|
||||
FIXED IN UNION|Fixed in Union
|
||||
Y TYPE|Y Type
|
||||
INLINE|InLine
|
||||
ANGLE PATTERN|Angle Pattern
|
||||
GAUZE|Gauze
|
||||
@@ -1,13 +0,0 @@
|
||||
LOAD DATA
|
||||
INFILE *
|
||||
INTO TABLE housing_types
|
||||
REPLACE
|
||||
FIELDS TERMINATED BY '|'
|
||||
(
|
||||
code
|
||||
,description
|
||||
)
|
||||
BEGINDATA
|
||||
LIFT OFF|Lift Off
|
||||
WALK IN|Walk In
|
||||
WALK THROUGH|Walk Through
|
||||
@@ -13,4 +13,3 @@ prty_id
|
||||
)
|
||||
BEGINDATA
|
||||
1|MIPADMIN|1001|08-NOV-07|||
|
||||
|
||||
|
||||
15374
Data/Seed/poco.ctl
15374
Data/Seed/poco.ctl
File diff suppressed because it is too large
Load Diff
@@ -1,16 +1,17 @@
|
||||
LOAD DATA
|
||||
INFILE *
|
||||
REPLACE
|
||||
INTO TABLE quote_statuses
|
||||
FIELDS TERMINATED BY ","
|
||||
REPLACE
|
||||
FIELDS TERMINATED BY '|'
|
||||
(
|
||||
CODE
|
||||
,DESCRIPTION
|
||||
code
|
||||
,description
|
||||
)
|
||||
BEGINDATA
|
||||
INP,In Progress
|
||||
AV,Available
|
||||
ACC,Accepted
|
||||
USERREJ,Rejected by user
|
||||
ACCREJ,Rejected because associated quote accepted
|
||||
LAPSE,Lapsed
|
||||
SELECTED|Selected by user for detailed quote
|
||||
INP|In Progress
|
||||
AV|Available
|
||||
ACCEPTED|Accepted
|
||||
REJECTED|Rejected by user
|
||||
SELREJ|Rejected because associated quote selected for detailed quote
|
||||
LAPSED|Lapsed
|
||||
|
||||
@@ -1,23 +0,0 @@
|
||||
LOAD DATA
|
||||
INFILE *
|
||||
INTO TABLE regulator_types
|
||||
REPLACE
|
||||
FIELDS TERMINATED BY '|'
|
||||
(
|
||||
code
|
||||
,description
|
||||
)
|
||||
BEGINDATA
|
||||
J90 ANGLED|J90 Angled
|
||||
DONKIN FIG 270R|Donkin Fig 270R
|
||||
DONKIN FIG 280/309|Donkin Fig 280/309
|
||||
DONKIN FIG 280|Donkin Fig 280
|
||||
RBI 2111|RBI 2111
|
||||
RBI 2011|RBI 2011
|
||||
RBI 2611|RBI 2611
|
||||
RBI 3211|RBI 3211
|
||||
RBE 1711|RBE 1711
|
||||
RBE 4011|RBE 4011
|
||||
SPERYN G1000|SPERYN G1000
|
||||
J48|J48
|
||||
DONKIN 226|Donkin 226
|
||||
@@ -1,13 +0,0 @@
|
||||
LOAD DATA
|
||||
INFILE *
|
||||
INTO TABLE relief_valve_types
|
||||
REPLACE
|
||||
FIELDS TERMINATED BY '|'
|
||||
(
|
||||
code
|
||||
,description
|
||||
)
|
||||
BEGINDATA
|
||||
INTEGRAL|Integral
|
||||
10L|10L
|
||||
VS811|VS811
|
||||
@@ -1,12 +0,0 @@
|
||||
LOAD DATA
|
||||
INFILE *
|
||||
REPLACE
|
||||
INTO TABLE slamshut_types
|
||||
FIELDS TERMINATED BY ","
|
||||
(
|
||||
CODE
|
||||
,DESCRIPTION
|
||||
)
|
||||
BEGINDATA
|
||||
INTEGRAL,Integral
|
||||
DF305,Donkin Fig 305
|
||||
@@ -1,12 +0,0 @@
|
||||
LOAD DATA
|
||||
INFILE *
|
||||
INTO TABLE slamshut_types
|
||||
REPLACE
|
||||
FIELDS TERMINATED BY '|'
|
||||
(
|
||||
code
|
||||
,description
|
||||
)
|
||||
BEGINDATA
|
||||
INTEGRAL|Integral
|
||||
DF305|Donkin Fig 305
|
||||
Reference in New Issue
Block a user