Files
mip/Data/BulkLoad/DATAITEM_ROLES.csv

91 lines
7.3 KiB
CSV

COLUMN_NAME ,Appendix Reference,INSTALL,STD INSTALL,OFMAT,EXCHANGE,STD EXCHANGE,REMOVE,STD REMOVE,ADVERSARIAL,ALTERATION,CHANGE CAPACITY,"ADDONS(EMS,AMR)",OTHER,Notes,DisplaySequence
ACCESS_ADDITIONAL,Site Detail.Access Instructions,O,O,O,O,O,O,O,O,O,O,O,O,,61
ACCESS_PASSWORD,Site Detail.Access Password,O,O,O,O,O,O,O,O,O,O,O,O,,62
AGENT_COMT_CODE,Supplier Agent.Telephone1/Telephone2/Fax/Email,M,M,M,M,M,M,M,M,M,M,M,M,,68
AGENT_CONTACT_VALUE,Supplier Agent.Telephone1/Telephone2/Fax/Email,M,M,M,M,M,M,M,M,M,M,M,M,,69
ALTY_CODE,Site Detail.Asset Location Code,M,M,M,M,M,M,M,M,M,M,M,M,,64
AMR_REQUIRED,Job Information.Additional Services.AMR,O-M5,O-M5,H,O-M5,O-M5,H,H,H,O-M5,O-M5,O-M5,O-M5,"The AMR may only be available for the Tripartite suppliers or BG, GW to confirm!",25
ANNUAL_QUANTITY,Job Information.Annual Quantity,O,O,O,O,O,H,H,H,O,O,O,O,if > 732 mwh go bespoke,32
ASSET_LOCATION_NOTES,Site Detail.Asset Location Notes,O,O,O,O,O,O,O,O,O,O,O,O,,65
BASE_REQUIRED,Job Information.Additional Services.Base,M,M,H,M,M,H,H,H,M,M,H,M,,26
BYPASS_REQUIRED,Job Information.Additional Services.By-pass,O,O,H,O,O,H,H,H,O,O,O,O,"If yes, warn user if twin stream is no",27
BYPASS_OTHER,Job Information.Additional Services.By-pass Other,O-M7,O-M7,H,O-M7,O-M7,H,H,H,O-M7,O-M7,O-M7,O-M7,,
CACA_CODE,Site Detail.Care Category,O,O,O,O,O,O,O,O,O,O,O,O,,66
CONVERTOR_REQUIRED,Job Information.Additional Services.Convertor,M,M,H,M,M,H,H,H,M,M,M,M,this can be an add-on for removals,28
CREATED_ON,,,,,,,,,,,,,,,
DOWNSTREAM_BOOSTER_OR_COMPRESS,Job Information.Booster/Compressor,M,M,M,M,M,H,H,H,M,M,M,M,,34
EMS_REQUIRED,Job Information.Additional Services.EMS,M,M,H,M,M,H,H,H,M,M,M,M,,29
ENTY_CODE,Job Information.Job Type,M,M,M,M,M,M,M,M,M,M,M,M,,43
EXISTING_CONVERTOR,Job Information.Existing Convertor,H,H,O,M,M,M,M,M,O,O,O,O,,72
EXISTING_LOGGER,Job Information.Logger,H,H,H,O,O,O,O,O,O,O,O,O,,71
EXISTING_PRTY_ID,Job Information.Existing Manufacturer,H,H,M,M,M,M,M,M,O,O,O,O,,
EXISTING_MESC_CODE,Job Information.Existing Meter Size,H,H,O-M6,O-M6,O-M6,O-M6,O-M6,O-M6,O-M6,O-M6,O,O,,36
EXISTING_METER_ASSET_PROVIDER,Job Information.Supplier / Job Information.Consumer(Meter Asset Manager),O,O,O,O,O,O,O,O,O,O,O,O,,54
EXISTING_METR_CODE,Job Information.Existing Model Code,H,H,M,M,M,M,M,M,O,M,O,O,,49
EXISTING_METER_OWNER,Job Information.Gas Act Owner,O,O,M,M,M,M,M,M,M,M,M,O,,38
EXISTING_METER_SERIAL_NO,Job Information.Existing Asset Serial Number,H,H,M,M,M,M,M,M,M,M,M,O,,35
EXISTING_METY_CODE,Job Information.Meter Type Existing ,H,H,O-M6,O-M6,O-M6,O-M6,O-M6,O-M6,O-M6,O-M6,O,O,,37
FIRST_ALT_BUILDING,Contact Address.Building,O,O,O,O,O,O,O,O,O,O,O,O,,7
FIRST_ALT_CITY,Contact Address.City,O,O,O,O,O,O,O,O,O,O,O,O,,8
FIRST_ALT_POSTCODE,Contact Address.Post Code,O,O,O,O,O,O,O,O,O,O,O,O,,13
FIRST_ALT_STREET,Contact Address.Street,O,O,O,O,O,O,O,O,O,O,O,O,,19
FIRST_ALT_SUB_BUILDING,Contact Address.Sub Building,O,O,O,O,O,O,O,O,O,O,O,O,,20
FIRST_CONTACT_EMAIL,Contact Address.Email,O,O,O,O,O,O,O,O,O,O,O,O,,9
FIRST_CONTACT_FAX,Contact Address.Fax,O,O,O,O,O,O,O,O,O,O,O,O,,11
FIRST_CONTACT_INITIALS,Contact Address.Contact Initials,O,O,O,O,O,O,O,O,O,O,O,O,,18
FIRST_CONTACT_NAME,Address.Contact Name,M,M,M,M,M,M,M,M,M,M,M,M,,3
FIRST_CONTACT_TELEPHONE_1,Contact Address.Telephone1,M,M,M,M,M,M,M,M,M,M,M,M,,21
FIRST_CONTACT_TELEPHONE_2,Contact Address.Telephone2,O,O,O,O,O,O,O,O,O,O,O,O,,23
FIRST_CONTACT_TITLE,Contact Address.Contact Title,O,O,O,O,O,O,O,O,O,O,O,O,,17
HOUSING_REQUIRED,Job Information.Additional Services.Housing,M,M,H,M,M,H,H,H,M,M,H,M,,30
ID,Enquiry Reference (not in spec appendix),M,M,M,M,M,M,M,M,M,M,M,M,,70
INDICATIVE_DATE,Job Information.Indicative Substantial Completion Date,O,O,O,O,O,O,O,O,O,O,O,O,,39
INDICATIVE_TIME,Job Information.Appointment Preference,O,O,O,O,O,O,O,O,O,O,O,O,,33
INSTALL_BUILDING,Address.Building,O-M1,O-M1,O-M1,O-M1,O-M1,O-M1,O-M1,O-M1,O-M1,O-M1,O-M1,O-M1,,1
INSTALL_CITY,Address.City,M,M,M,M,M,M,M,M,M,M,M,M,,2
INSTALL_POSTCODE,Address.Post Code,M,M,M,M,M,M,M,M,M,M,M,M,,4
INSTALL_STREET,Address.Street,M,M,M,M,M,M,M,M,M,M,M,M,,5
INSTALL_SUB_BUILDING,Address.Sub Building,O-M1,O-M1,O-M1,O-M1,O-M1,O-M1,O-M1,O-M1,O-M1,O-M1,O-M1,O-M1,,6
JOB_DESCRIPTION,Job Information.Job Description,O,O,O,O,O,O,O,O,O,O,O,O,,42
LOAD_CONTROL_TYPE,Job Information.Load Control Type,M,M,H,M,M,H,H,H,O,M,O,O,,44
MARKET_SECTOR_CODE,Job Information.Market Sector Code,O,O,O,O,O,O,O,O,O,O,O,O,,45
MPRN,Site Detail.MPRN,O-M4,O-M4,M,M,M,M,M,M,M,M,M,O,,67
MPRN_ALT,Site Detail.Additional Information,O-M4,O-M4,O,O,O,O,O,O,O,O,O,O,,63
OTHER_INFORMATION,Job Information.Other Information,O,O,O,O,O,O,O,O,O,O,O,O,,50
OTHER_PROJECT_REFERENCE,Job Information.Other Related Projects,O,O,O,O,O,O,O,O,O,O,O,O,,51
QMAX,Job Information.Measuring Capacity Qmax,M,O-M2,O,M,O-M2,O,O,O,O,O-M2,O,O,,46
QMIN,Job Information.Measuring Capacity Qmin,O,O,O,O,O,O,O,O,O,O,O,O,,47
REQUIRED_IP_DETAILS,Job Information.IP Details,O-M3,H,O-M3,O-M3,H,O-M3,H,O-M3,O-M3,O-M3,O-M3,O-M3,if service pressure is IP,40
REQUIRED_IP_MBAR,Job Information.IP Inlet pressure,O-M3,H,O-M3,O-M3,H,O-M3,H,O-M3,O-M3,O-M3,O-M3,O-M3,if service pressure is IP,41
REQUIRED_MESC_CODE,Job Information.Meter Size,H,O-M2,H,H,O-M2,H,H,H,H,O-M2,H,O,,48
REQUIRED_METERING_PRESSURE,Job Information.Required Meter Pressure,M,M,M,M,M,M,M,M,M,M,O,O,,52
REQUIRED_SVCP_CODE,Job Information.Service Pressure,O-M3,M,O-M3,O-M3,M,O-M3,M,O-M3,O-M3,O-M3,O-M3,O-M3,,53
SECOND_ALT_BUILDING,Second Contact Address.Building,O,O,O,O,O,O,O,O,O,O,O,O,,56
SECOND_ALT_CITY,Second Contact Address.City,O,O,O,O,O,O,O,O,O,O,O,O,,57
SECOND_ALT_POSTCODE,Second Contact Address.Post Code,O,O,O,O,O,O,O,O,O,O,O,O,,58
SECOND_ALT_STREET,Second Contact Address.Street,O,O,O,O,O,O,O,O,O,O,O,O,,59
SECOND_ALT_SUB_BUILDING,Second Contact Address.Sub Building,O,O,O,O,O,O,O,O,O,O,O,O,,60
SECOND_CONTACT_EMAIL,Second Contact Address.Email,O,O,O,O,O,O,O,O,O,O,O,O,,10
SECOND_CONTACT_FAX,Contact Address.Fax,O,O,O,O,O,O,O,O,O,O,O,O,,12
SECOND_CONTACT_INITIALS,Second Contact Address.Contact Initials,O,O,O,O,O,O,O,O,O,O,O,O,,15
SECOND_CONTACT_NAME,Second Contact Address.Second Contact Name,O,O,O,O,O,O,O,O,O,O,O,O,,16
SECOND_CONTACT_TELEPHONE_1,Contact Address.Telephone1,O,O,O,O,O,O,O,O,O,O,O,O,,22
SECOND_CONTACT_TELEPHONE_2,Contact Address.Telephone2,O,O,O,O,O,O,O,O,O,O,O,O,,24
SECOND_CONTACT_TITLE,Second Contact Address.Contact Title,O,O,O,O,O,O,O,O,O,O,O,O,,14
TRANSACTION_REFERENCE,Job Site Details.Transaction Reference,O,O,O,O,O,O,O,O,O,O,O,O,,55
TWIN_STREAM_REQUIRED,Job Information.Additional Services.Twin Stream,M,M,H,M,M,H,H,H,M,M,H,M,,31
UPDATED_BY,,,,,,,,,,,,,,,
UPDATED_ON,,,,,,,,,,,,,,,
,,,,,,,,,,,,,,,
,,,,,,,,,,,,,,,
,,,,,,,,,,,,,,,
,Optional-Mandatory Special Cases,,,,,,,,,,,,,,
,O-M1: INSTALL_SUB_BUILDING AND/OR INSTALL.BUILDING MUST BE COMPLETED,,,,,,,,,,,,,,
,O-M2: IF REQUIRED_MESC_CODE IS NOT COMPLETED OR IS 'OTHER' THEN QMAX MUST BE COMPLETED,,,,,,,,,,,,,,
,O-M3: IF REQUIRED_SVCP_CODE = 'IP' THEN REQUIRED_IP_DETAILS MUST BE COMPLETED,,,,,,,,,,,,,,
,O-M4: IF MPRN IS NOT COMPLETED THEN MPRN_ALT MUST BE COMPLETED,,,,,,,,,,,,,,
,O-M5: AMR AVAILABILITY IS DETERMINED BY TRIPARTITE AGREEMENT,,,,,,,,,,,,,,
,O-M6: IF EXISTING_METR_CODE IS 'OTHER' THEN EXISTING_MESC_CODE AND EXISTING_METY_CODE MUST BE COMPLETED,,,,,,,,,,,,,,
,O-M7: IF BY_PASS IS 'OTHER' THEN BYPASS_OTHER MUST BE COMPLETED,,,,,,,,,,,,,,
,,,,,,,,,,,,,,,